Literature DB >> 19544775

Comparison of organ residence time estimation methods for radioimmunotherapy dosimetry and treatment planning--patient studies.

Bin He1, Richard L Wahl, George Sgouros, Yong Du, Heather Jacene, Wayne R Kasecamp, Ian Flinn, Richard J Hammes, Jay Bianco, Brad Kahl, Eric C Frey.   

Abstract

The estimation of organ residence time is essential for high-dose myeloablative regimens in radioimmunotherapy (RIT). Frequently, this estimation is based on a series of simple planar scans and planar processing. The authors previously performed a simulation study which demonstrated that the accuracy of this methodology is limited compared to a hybrid planar/SPECT residence time estimation method. In this work the authors applied this hybrid method to data from a clinical trial of high-dose myeloablative yttrium-90 ibritumomab tiuxetan therapy. Image data acquired from 18 patients were comprised of planar scans at five time points ranging from 1 to 144 h postinjection and abdominal and thoracic SPECT/CT scans obtained at 24 h postinjection. The simple planar processing method used in this work was based on the geometric mean method with energy window based scatter compensation. No explicit background subtraction nor object or source thickness corrections were performed. The SPECT projections were reconstructed using iterative reconstruction with compensations for attenuation, scatter, and full collimator-detector response. Large differences were observed when residence times were estimated using the simple planar method compared to the hybrid method. The differences were not constant but varied in magnitude and sign. For the dose-limiting organ (liver), the average difference was -18% and variation in the difference was 19%, similar to the differences observed in a previously reported simulation study. The authors also looked at the relationship between the weight of the patient and the liver residence time and found that there was no meaningful correlation for either method. This indicates that weight would not be an adequate proxy for an experimental estimate of residence time when choosing the activity to administer for therapy. The authors conclude that methods such as the simple planar method used here are inadequate for RIT treatment planning. More sophisticated methods, such as the hybrid SPECT/planar method investigated here, are likely to be better predictors of organ dose and, as a result, organ toxicities.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19544775      PMCID: PMC2851232          DOI: 10.1118/1.3100265

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

2.  In vivo quantitation of lesion radioactivity using external counting methods.

Authors:  S R Thomas; H R Maxon; J G Kereiakes
Journal:  Med Phys       Date:  1976 Jul-Aug       Impact factor: 4.071

Review 3.  Radioimmunotherapy of B-cell non-Hodgkin's lymphoma: from clinical trials to clinical practice.

Authors:  Malik E Juweid
Journal:  J Nucl Med       Date:  2002-11       Impact factor: 10.057

Review 4.  Pretargeted radioimmunotherapy of cancer: progress step by step.

Authors:  Otto C Boerman; Frank G van Schaijk; Wim J G Oyen; Frans H M Corstens
Journal:  J Nucl Med       Date:  2003-03       Impact factor: 10.057

5.  OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine.

Authors:  Michael G Stabin; Richard B Sparks; Eric Crowe
Journal:  J Nucl Med       Date:  2005-06       Impact factor: 10.057

Review 6.  Administration guidelines for radioimmunotherapy of non-Hodgkin's lymphoma with (90)Y-labeled anti-CD20 monoclonal antibody.

Authors:  Henry N Wagner; Gregory A Wiseman; Carol S Marcus; Hani A Nabi; Conrad E Nagle; Darlene M Fink-Bennett; Dominick M Lamonica; Peter S Conti
Journal:  J Nucl Med       Date:  2002-02       Impact factor: 10.057

7.  Volume reduction versus radiation dose for tumors in previously untreated lymphoma patients who received iodine-131 tositumomab therapy. Conjugate views compared with a hybrid method.

Authors:  Kenneth F Koral; Isaac R Francis; Stewart Kroll; Kenneth R Zasadny; Mark S Kaminski; Richard L Wahl
Journal:  Cancer       Date:  2002-02-15       Impact factor: 6.860

Review 8.  An overview of imaging techniques and physical aspects of treatment planning in radioimmunotherapy.

Authors:  P K Leichner; K F Koral; R J Jaszczak; A J Green; G T Chen; J C Roeske
Journal:  Med Phys       Date:  1993 Mar-Apr       Impact factor: 4.071

9.  High-dose radioimmunotherapy versus conventional high-dose therapy and autologous hematopoietic stem cell transplantation for relapsed follicular non-Hodgkin lymphoma: a multivariable cohort analysis.

Authors:  Ajay K Gopal; Theodore A Gooley; David G Maloney; Stephen H Petersdorf; Janet F Eary; Joseph G Rajendran; Sharon A Bush; Lawrence D Durack; Jane Golden; Paul J Martin; Dana C Matthews; Frederick R Appelbaum; Irwin D Bernstein; Oliver W Press
Journal:  Blood       Date:  2003-05-15       Impact factor: 22.113

10.  Importance of intra-therapy single-photon emission tomographic imaging in calculating tumour dosimetry for a lymphoma patient.

Authors:  K F Koral; K R Zasadny; F M Swailem; S F Buchbinder; I R Francis; M S Kaminski; R L Wahl
Journal:  Eur J Nucl Med       Date:  1991
View more
  12 in total

1.  EQPlanar: a maximum-likelihood method for accurate organ activity estimation from whole body planar projections.

Authors:  N Song; B He; R L Wahl; E C Frey
Journal:  Phys Med Biol       Date:  2011-08-03       Impact factor: 3.609

2.  Activity quantification combining conjugate-view planar scintigraphies and SPECT/CT data for patient-specific 3-D dosimetry in radionuclide therapy.

Authors:  Yannick Berker; Andreas Goedicke; Gerrit J Kemerink; Til Aach; Bernd Schweizer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-08       Impact factor: 9.236

3.  A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

Authors:  Abhinav K Jha; Brian Caffo; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-03-16       Impact factor: 3.609

4.  3D dosimetry in patients with early breast cancer undergoing Intraoperative Avidination for Radionuclide Therapy (IART) combined with external beam radiation therapy.

Authors:  Mahila E Ferrari; Marta Cremonesi; Amalia Di Dia; Francesca Botta; Concetta De Cicco; Anna Sarnelli; Piernicola Pedicini; Michele Calabrese; Roberto Orecchia; Guido Pedroli; Giovanni Paganelli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-08-14       Impact factor: 9.236

5.  Development and evaluation of convergent and accelerated penalized SPECT image reconstruction methods for improved dose-volume histogram estimation in radiopharmaceutical therapy.

Authors:  Lishui Cheng; Robert F Hobbs; George Sgouros; Eric C Frey
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

6.  Radiobiologic optimization of combination radiopharmaceutical therapy applied to myeloablative treatment of non-Hodgkin lymphoma.

Authors:  Robert F Hobbs; Richard L Wahl; Eric C Frey; Yvette Kasamon; Hong Song; Peng Huang; Richard J Jones; George Sgouros
Journal:  J Nucl Med       Date:  2013-08-05       Impact factor: 10.057

7.  A theoretical dose-escalation study based on biological effective dose in radioimmunotherapy with (90)Y-ibritumomab tiuxetan (Zevalin).

Authors:  Massimiliano Pacilio; Margherita Betti; Francesco Cicone; Carolina Del Mastro; Livia Montani; Laura Chiacchiararelli; Alessia Monaco; Enrico Santini; Francesco Scopinaro
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-01-13       Impact factor: 9.236

8.  Strengths and Weaknesses of a Planar Whole-Body Method of (153)Sm Dosimetry for Patients with Metastatic Osteosarcoma and Comparison with Three-Dimensional Dosimetry.

Authors:  Donika Plyku; David M Loeb; Andrew R Prideaux; Sébastien Baechler; Richard L Wahl; George Sgouros; Robert F Hobbs
Journal:  Cancer Biother Radiopharm       Date:  2015-11       Impact factor: 3.099

9.  Kidney dosimetry in ¹⁷⁷Lu and ⁹⁰Y peptide receptor radionuclide therapy: influence of image timing, time-activity integration method, and risk factors.

Authors:  F Guerriero; M E Ferrari; F Botta; F Fioroni; E Grassi; A Versari; A Sarnelli; M Pacilio; E Amato; L Strigari; L Bodei; G Paganelli; M Iori; G Pedroli; M Cremonesi
Journal:  Biomed Res Int       Date:  2013-06-20       Impact factor: 3.411

10.  Radioimmunotherapy of B-Cell Non-Hodgkin's Lymphoma.

Authors:  Caroline Bodet-Milin; Ludovic Ferrer; Amandine Pallardy; Thomas Eugène; Aurore Rauscher; Jacques Barbet; Françoise Kraeber-Bodéré
Journal:  Front Oncol       Date:  2013-07-11       Impact factor: 6.244

View more