Reproducibility of cardiac output measurement by the nitrous oxide rebreathing technique.

Philip J Peyton1, Michael Bailey, Bruce R Thompson.   

Abstract

Techniques for the measurement of cardiac output from soluble gas uptake by the lungs include the rebreathing method using nitrous oxide. The accuracy of this technique is well accepted, but its repeatability of measurement (precision) has not been well documented. We assessed the repeatability of measurements of pulmonary blood flow by the Innocor, a device employing the nitrous oxide rebreathing method. Successive paired measurements of pulmonary blood flow were made separated by a 5 min interval by the nitrous oxide rebreathing method, in 8 patients pre- or post cardiac surgery, and in 8 healthy volunteers. The standard deviation of the difference between first and second measurements was 0.84 l/min in the cardiac surgery group, and 1.25 l/min in the healthy volunteers. There was no significant bias in successive paired measurements of pulmonary blood flow in either the cardiac surgery patients (mean [95%CI] = -0.02 l/min [-0.62 to 0.57] or the healthy volunteers (0.00 l/min [-0.88 to 0.88]). Intra-class correlation coefficients for the healthy and cardiac patients were 0.77 and 0.64 respectively. Multiple measurements should be made and averaged when using the inert gas rebreathing technique for pulmonary blood flow determination. When comparing agreement with other methods for cardiac output measurement, the internal consistency of both methods should be considered.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19543798     DOI: 10.1007/s10877-009-9187-7

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  20 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique.

Authors:  Anders Gabrielsen; Regitze Videbaek; Morten Schou; Morten Damgaard; Jens Kastrup; Peter Norsk
Journal:  Clin Sci (Lond)       Date:  2002-02       Impact factor: 6.124

3.  Analysis of uncertainty in theoretical methods of cardiac output measurement using the "Monte Carlo" technique.

Authors:  R R Kennedy; A B Baker
Journal:  Br J Anaesth       Date:  1993-09       Impact factor: 9.166

4.  Pulmonary blood flow and tissue volume: model analysis of rebreathing estimation methods.

Authors:  G M Burma; G M Saidel
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1983-07

5.  Pulmonary blood flow, diffusing, capacity and tissue volume by rebreathing: theory.

Authors:  C Hook; M Meyer
Journal:  Respir Physiol       Date:  1982-05

6.  Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow.

Authors:  P Christensen; P Clemensen; P K Andersen; S W Henneberg
Journal:  Crit Care Med       Date:  2000-01       Impact factor: 7.598

7.  Cardiac output by rebreathing in patients with cardiopulmonary diseases.

Authors:  M C Kallay; R W Hyde; R J Smith; R L Rothbard; B F Schreiner
Journal:  J Appl Physiol (1985)       Date:  1987-07

8.  Non-invasive measurement of cardiac output by a single breath constant expiratory technique.

Authors:  U Elkayam; A F Wilson; J Morrison; P Meltzer; J Davis; P Klosterman; J Louvier; W L Henry
Journal:  Thorax       Date:  1984-02       Impact factor: 9.139

9.  Measurement of pulmonary capillary blood flow by a nitrous oxide rebreathing technique.

Authors:  T Stokke; H Burchardi; H Angerer; I Hensel
Journal:  Acta Anaesthesiol Scand       Date:  1986-10       Impact factor: 2.105

10.  Measurement of effective pulmonary blood flow by soluble gas uptake in patients with chronic airflow obstruction.

Authors:  R J Pierce; C F McDonald; C A Thuys; P D Rochford; C E Barter
Journal:  Thorax       Date:  1987-08       Impact factor: 9.139

View more
  8 in total

1.  Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis.

Authors:  Sebastiaan A Bartels; Wim J Stok; Rick Bezemer; Remco J Boksem; Jeroen van Goudoever; Thomas G V Cherpanath; Johannes J van Lieshout; Berend E Westerhof; John M Karemaker; Can Ince
Journal:  J Clin Monit Comput       Date:  2011-10-15       Impact factor: 2.502

2.  Biological aortic age derived from the arterial pressure waveform.

Authors:  Shigeki Shibata; Benjamin D Levine
Journal:  J Appl Physiol (1985)       Date:  2011-02-03

3.  Acute kidney injury after valvular heart surgery and early changes in cardiac function and structure.

Authors:  Daniel P Olsson; Christopher Eck Arvstrand; Ulrik Sartipy; Martin J Holzmann
Journal:  Cardiorenal Med       Date:  2014-10-17       Impact factor: 2.041

4.  Influence of bag volume on reproducibility of inert gas rebreathing pulmonary blood flow measurements in patients with pulmonary diseases.

Authors:  Joachim Saur; Franziska Kraus; Joachim Brade; Dariusch Haghi; Michael Behnes; Ursula Hoffmann; Martin Borggrefe; Jens J Kaden; Frederik Trinkmann
Journal:  Lung       Date:  2013-07-26       Impact factor: 2.584

5.  Pulmonary vasospasm in systemic sclerosis: noninvasive techniques for detection.

Authors:  Gregory J Keir; Arjun Nair; Stamatia Giannarou; Guang-Zhong Yang; Paul Oldershaw; S John Wort; Peter MacDonald; David M Hansell; Athol U Wells
Journal:  Pulm Circ       Date:  2015-09       Impact factor: 3.017

6.  Indirect measurement of absolute cardiac output during exercise in simulated altered gravity is highly dependent on the method.

Authors:  Richard S Whittle; Lindsay M Stapleton; Lonnie G Petersen; Ana Diaz-Artiles
Journal:  J Clin Monit Comput       Date:  2021-10-22       Impact factor: 1.977

7.  Mechanisms underlying elevated SBP differ with adiposity in young adults: the Enigma study.

Authors:  Jessica E Middlemiss; Karen L Miles; Barry J McDonnell; Kaisa M Maki-Petaja; John R Cockcroft; Ian B Wilkinson; Carmel M McEniery
Journal:  J Hypertens       Date:  2016-02       Impact factor: 4.844

8.  Evaluation of inert gas rebreathing for determination of cardiac output: influence of age, gender and body size.

Authors:  Jessica E Middlemiss; Alex Cocks; Kaido Paapstel; Kaisa M Maki-Petaja; Ian B Wilkinson; Carmel M McEniery
Journal:  Hypertens Res       Date:  2018-12-18       Impact factor: 3.872

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.