Cardiac output by rebreathing in patients with cardiopulmonary diseases.

M C Kallay, R W Hyde, R J Smith, R L Rothbard, B F Schreiner.   

Abstract

Noninvasive estimates of cardiac output by rebreathing soluble gases (Qc) can be unreliable in patients with cardiopulmonary diseases because of uneven distribution of ventilation to lung gas volume and pulmonary blood flow. To evaluate this source of error, we compared rebreathing Qc with invasive measurements of cardiac output performed by indicator-dilution methods (COID) in 39 patients with cardiac or pulmonary diseases. In 16 patients with normal lung volumes and 1-s forced expiratory volumes (FEV1), Qc measured with acetylene [Qc(C2H2)] overestimated COID insignificantly by 2 +/- 9% (SD). In subjects with mild to moderate obstructive lung disease, Qc(C2H2) slightly overestimated COID by 6 +/- 15% (P = 0.11). In patients with restrictive disease or combined obstructive and restrictive disease, Qc(C2H2) underestimated COID significantly by 9 +/- 14% (P less than 0.04). The magnitude of the discrepancy between Qc and COID correlated with size of the volume rebreathed and an index of uneven ventilation calculated from helium mixing during rebreathing that determined a dead space to inspired volume ratio (VRD/VI). Rebreathing volumes less than 40% of the predicted FEV or VRD/VI of 0.4 or greater identified all subjects with a discrepancy between Qc(C2H2) and COID of 20% or greater.

Entities:  

Mesh:

Year:  1987        PMID: 3624125     DOI: 10.1152/jappl.1987.63.1.201

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  8 in total

1.  Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients.

Authors:  Liang Dong; Jian-an Wang; Chen-yang Jiang
Journal:  J Zhejiang Univ Sci B       Date:  2005-12       Impact factor: 3.066

2.  Reproducibility of cardiac output measurement by the nitrous oxide rebreathing technique.

Authors:  Philip J Peyton; Michael Bailey; Bruce R Thompson
Journal:  J Clin Monit Comput       Date:  2009-06-19       Impact factor: 2.502

3.  The impact of pulmonary disease on noninvasive measurement of cardiac output by the inert gas rebreathing method.

Authors:  Joachim Saur; Frederik Trinkmann; Christina Doesch; Armin Scherhag; Joachim Brade; Stefan O Schoenberg; Martin Borggrefe; Jens J Kaden; Theano Papavassiliu
Journal:  Lung       Date:  2010-07-31       Impact factor: 2.584

4.  Effective pulmonary blood flow in normal children at rest.

Authors:  J J Bowyer; J O Warner; D M Denison
Journal:  Thorax       Date:  1988-12       Impact factor: 9.139

5.  Noninvasive estimation of cardiac output with nonprescribed breathing.

Authors:  M E Cabrera; G M Saidel; M H Cohen
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

6.  [Noninvasive determination of cardiac output in ventilated patients . Clinical evaluation of a simplified quick method].

Authors:  J Reutershan; T Kapp; K Unertl; R Fretschner
Journal:  Anaesthesist       Date:  2003-09       Impact factor: 1.041

7.  A forty-year follow-up of the Dallas Bed Rest and Training study: the effect of age on the cardiovascular response to exercise in men.

Authors:  Jonathan M McGavock; Jeffrey L Hastings; Peter G Snell; Darren K McGuire; Eric L Pacini; Benjamin D Levine; Jere H Mitchell
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2009-02-05       Impact factor: 6.053

8.  Noninvasive Assessment of Cardiac Output: Accuracy and Precision of the Closed-Circuit Acetylene Rebreathing Technique for Cardiac Output Measurement.

Authors:  E Ashley Hardin; Douglas Stoller; Justin Lawley; Erin J Howden; Michinari Hieda; James Pawelczyk; Sara Jarvis; Kim Prisk; Satyam Sarma; Benjamin D Levine
Journal:  J Am Heart Assoc       Date:  2020-08-27       Impact factor: 5.501

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.