OBJECTIVE: Rapid technical developments and an expanding list of applications that have supplanted less accurate or more invasive diagnostic tests have led to a dramatic increase in the use of body CT in medical practice since its introduction in 1975. Our purpose here is to discuss medical justification of the small potential risk associated with the ionizing radiation used in CT and to provide perspectives on practice-specific decisions that can maximize overall patient benefit. In addition, we review available dose management and optimization techniques. CONCLUSION: Dose reduction strategies described in this article must be well understood and properly used, but also require broad-based practice strategies that extend beyond the CT scanner console and default, generic manufacturer settings. In the final analysis, physicians must request the imaging examination that best addresses the specific medical question without allowing worries about radiation to dissuade them or their patients from obtaining needed CT examinations. Ongoing efforts to ensure that CT examinations are both medically justified and optimally performed must continue, and education must be provided to the medical community and general public that put both the potential risks--and benefits--of CT examinations into proper perspective.
OBJECTIVE: Rapid technical developments and an expanding list of applications that have supplanted less accurate or more invasive diagnostic tests have led to a dramatic increase in the use of body CT in medical practice since its introduction in 1975. Our purpose here is to discuss medical justification of the small potential risk associated with the ionizing radiation used in CT and to provide perspectives on practice-specific decisions that can maximize overall patient benefit. In addition, we review available dose management and optimization techniques. CONCLUSION: Dose reduction strategies described in this article must be well understood and properly used, but also require broad-based practice strategies that extend beyond the CT scanner console and default, generic manufacturer settings. In the final analysis, physicians must request the imaging examination that best addresses the specific medical question without allowing worries about radiation to dissuade them or their patients from obtaining needed CT examinations. Ongoing efforts to ensure that CT examinations are both medically justified and optimally performed must continue, and education must be provided to the medical community and general public that put both the potential risks--and benefits--of CT examinations into proper perspective.
Authors: Joel G Fletcher; Maurits J Wiersema; Michael A Farrell; Jeff L Fidler; Lawrence J Burgart; Takashi Koyama; C Daniel Johnson; David H Stephens; Ellen M Ward; W Scott Harmsen Journal: Radiology Date: 2003-10 Impact factor: 11.105
Authors: C Daniel Johnson; Mei-Hsiu Chen; Alicia Y Toledano; Jay P Heiken; Abraham Dachman; Mark D Kuo; Christine O Menias; Betina Siewert; Jugesh I Cheema; Richard G Obregon; Jeff L Fidler; Peter Zimmerman; Karen M Horton; Kevin Coakley; Revathy B Iyer; Amy K Hara; Robert A Halvorsen; Giovanna Casola; Judy Yee; Benjamin A Herman; Lawrence J Burgart; Paul J Limburg Journal: N Engl J Med Date: 2008-09-18 Impact factor: 91.245
Authors: C T Sofocleous; R G Nascimento; M Gonen; M Theodoulou; A M Covey; L A Brody; S M Solomon; R Thornton; Y Fong; G I Getrajdman; K T Brown Journal: AJR Am J Roentgenol Date: 2007-10 Impact factor: 3.959
Authors: Daniel I Rosenthal; Jeffrey B Weilburg; Thomas Schultz; Janet C Miller; Victoria Nixon; Keith J Dreyer; James H Thrall Journal: J Am Coll Radiol Date: 2006-10 Impact factor: 5.532
Authors: Adam C Turner; Maria Zankl; John J DeMarco; Chris H Cagnon; Di Zhang; Erin Angel; Dianna D Cody; Donna M Stevens; Cynthia H McCollough; Michael F McNitt-Gray Journal: Med Phys Date: 2010-04 Impact factor: 4.071
Authors: Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough Journal: Imaging Med Date: 2009-10
Authors: Lucas L Geyer; Markus Körner; Andreas Harrieder; Fabian G Mueck; Zsuzsanna Deak; Stefan Wirth; Ulrich Linsenmaier Journal: Br J Radiol Date: 2016-02-08 Impact factor: 3.039
Authors: Christopher P Favazza; Lifeng Yu; Shuai Leng; James M Kofler; Cynthia H McCollough Journal: J Comput Assist Tomogr Date: 2015 May-Jun Impact factor: 1.826