Literature DB >> 19521736

Feasibility of whole-body functional mouse imaging using helical pinhole SPECT.

Scott D Metzler1, Sreekanth Vemulapalli, Ronald J Jaszczak, Gamal Akabani, Bennett B Chin.   

Abstract

PURPOSE: Detailed in vivo whole-body biodistributions of radiolabeled tracers may characterize the longitudinal progression of disease, and changes with therapeutic interventions. Small-animal imaging in mice is particularly attractive due to the wide array of well characterized genetically and surgically created models of disease. Single Photon Emission Computed Tomography (SPECT) imaging using pinhole collimation provides high resolution and sensitivity, but conventional methods using circular acquisitions result in severe image truncation and incomplete sampling of data, which prevent the accurate determination of whole-body radiotracer biodistributions. This study describes the feasibility of helical acquisition paths to mitigate these effects. PROCEDURES: Helical paths of pinhole apertures were implemented using an external robotic stage aligned with the axis of rotation (AOR) of the scanner. Phantom and mouse scans were performed using helical paths and either circular or bi-circular orbits at the same radius of rotation (ROR). The bi-circular orbits consisted of two 360-degree scans separated by an axial shift to increase the axial field of view (FOV) and to improve the complete-sampling properties.
RESULTS: Reconstructions of phantoms and mice acquired with helical paths show good image quality and are visually free of both truncation and axial-blurring artifacts. Circular orbits yielded reconstructions with both artifacts and a limited effective FOV. The bi-circular scans enlarged the axial FOV, but still suffered from truncation and sampling artifacts.
CONCLUSIONS: Helical paths can provide complete sampling data and large effective FOV, yielding 3D full-body in vivo biodistributions while still maintaining a small distance from the aperture to the object for good sensitivity and resolution.

Entities:  

Mesh:

Year:  2009        PMID: 19521736      PMCID: PMC2821028          DOI: 10.1007/s11307-009-0234-z

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  26 in total

1.  Analytic determination of pinhole collimator sensitivity with penetration.

Authors:  S D Metzler; J E Bowsher; M F Smith; R J Jaszczak
Journal:  IEEE Trans Med Imaging       Date:  2001-08       Impact factor: 10.048

2.  Analytic determination of the resolution-equivalent effective diameter of a pinhole collimator.

Authors:  Roberto Accorsi; Scott D Metzler
Journal:  IEEE Trans Med Imaging       Date:  2004-06       Impact factor: 10.048

3.  A modified uniform Cramer-Rao bound for multiple pinhole aperture design.

Authors:  L J Meng; N H Clinthorne
Journal:  IEEE Trans Med Imaging       Date:  2004-07       Impact factor: 10.048

4.  Molecular imaging of small animals with a triple-head SPECT system using pinhole collimation.

Authors:  S D Metzler; R J Jaszczak; N H Patil; S Vemulapalli; G Akabani; B B Chin
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

5.  Pinhole emission computed tomography: method and experimental evaluation.

Authors:  J Palmer; P Wollmer
Journal:  Phys Med Biol       Date:  1990-03       Impact factor: 3.609

6.  Single-photon emission tomography with a 12-pinhole collimator.

Authors:  B Hasegawa; D Kirch; D Stern; M Adams; J Sklar; T Johnson; P Steele
Journal:  J Nucl Med       Date:  1982-07       Impact factor: 10.057

7.  Cell therapy in murine atherosclerosis: in vivo imaging with high-resolution helical SPECT.

Authors:  Sreekanth Vemulapalli; Scott D Metzler; Gamal Akabani; Neil A Petry; Nelsen J Niehaus; Xialin Liu; Nikhil H Patil; Kim L Greer; Ronald J Jaszczak; R Edward Coleman; Chunming Dong; Pascal J Goldschmidt-Clermont; Bennett B Chin
Journal:  Radiology       Date:  2007-01       Impact factor: 11.105

8.  Submillimeter total-body murine imaging with U-SPECT-I.

Authors:  Brendan Vastenhouw; Freek Beekman
Journal:  J Nucl Med       Date:  2007-03       Impact factor: 10.057

9.  Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice.

Authors:  Max C Wu; Bruce H Hasegawa; Michael W Dae
Journal:  Med Phys       Date:  2002-12       Impact factor: 4.071

10.  Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT-CT scanners.

Authors:  Frank P Difilippo
Journal:  Phys Med Biol       Date:  2008-07-17       Impact factor: 3.609

View more
  3 in total

1.  Analytic Determination of Rectangular-Pinhole Sensitivity With Penetration.

Authors:  Scott D Metzler; Stephen C Moore
Journal:  IEEE Trans Med Imaging       Date:  2019-08-19       Impact factor: 10.048

2.  Micro-single-photon emission computed tomography image acquisition and quantification of sodium-iodide symporter-mediated radionuclide accumulation in mouse thyroid and salivary glands.

Authors:  Michael P Brandt; Richard T Kloos; Daniel H Shen; Xiaoli Zhang; Yu-Yu Liu; Sissy M Jhiang
Journal:  Thyroid       Date:  2012-04-27       Impact factor: 6.568

3.  Improvement of Performance of Cardiac SPECT Camera Using Curved Detectors With Pinholes.

Authors:  Joyoni Dey
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-10       Impact factor: 1.679

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.