Literature DB >> 11513024

Analytic determination of pinhole collimator sensitivity with penetration.

S D Metzler1, J E Bowsher, M F Smith, R J Jaszczak.   

Abstract

Pinhole collimators are widely used to image small organs and animals. The sensitivity of knife-edge pinhole collimators has been previously estimated using an "effective diameter" formulation and experimentally described using a sin(x) theta fit, where theta is the angle between the line segment from the center of the aperture to the photon source and its projection onto the plane of the aperture. An analytic form of the sensitivity of the pinhole collimator is derived in this paper. A numerical formula for predicting the sin(x) theta form of the sensitivity is calculated from the analytic form. Experimental data are compared with the theoretical estimate and the sin(x) theta prediction. The agreement is excellent.

Entities:  

Mesh:

Year:  2001        PMID: 11513024     DOI: 10.1109/42.938241

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  22 in total

1.  Analytic derivation of pinhole collimation sensitivity for a general source model using spherical harmonics.

Authors:  Yu-Sheng Li; James E Oldendick; Wei Chang
Journal:  Phys Med Biol       Date:  2010-04-19       Impact factor: 3.609

Review 2.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

3.  Investigation of imaging properties for submillimeter rectangular pinholes.

Authors:  Dan Xia; Stephen C Moore; Mi-Ae Park; Morgan Cervo; Scott D Metzler
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

Review 4.  Advances in technical aspects of myocardial perfusion SPECT imaging.

Authors:  Piotr J Slomka; James A Patton; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2009-02-26       Impact factor: 5.952

5.  A line-source method for aligning on-board and other pinhole SPECT systems.

Authors:  Susu Yan; James Bowsher; Fang-Fang Yin
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

6.  Analytic Determination of Rectangular-Pinhole Sensitivity With Penetration.

Authors:  Scott D Metzler; Stephen C Moore
Journal:  IEEE Trans Med Imaging       Date:  2019-08-19       Impact factor: 10.048

7.  Multidivergent-beam stationary cardiac SPECT.

Authors:  Gengsheng L Zeng; Andrew M Stevens
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

8.  Improvement of Performance of Cardiac SPECT Camera Using Curved Detectors With Pinholes.

Authors:  Joyoni Dey
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-10       Impact factor: 1.679

9.  Geometric Sensitivity of a Pinhole Collimator.

Authors:  Howard Jacobowitz; Scott D Metzler
Journal:  Int J Math Math Sci       Date:  2010-02-19

10.  Multi-pinhole collimator design for small-object imaging with SiliSPECT: a high-resolution SPECT.

Authors:  S Shokouhi; S D Metzler; D W Wilson; T E Peterson
Journal:  Phys Med Biol       Date:  2008-12-16       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.