Literature DB >> 15191149

Analytic determination of the resolution-equivalent effective diameter of a pinhole collimator.

Roberto Accorsi1, Scott D Metzler.   

Abstract

To account for photon penetration, the formulas used to calculate the geometric resolution of a pinhole collimator use an equivalent diameter d(e) rather than the physical diameter of the aperture. The expression commonly used for d(e), however, was originally derived to account for penetration in sensitivity calculations. In this paper, we show that the concept of equivalent diameter is also applicable to resolution calculations, propose angular-dependent expressions for d(e) specific to resolution calculations, and discuss the limits of their applicability and how they compare to other expressions. Results show that for normal incidence Paix's expression for d(e) tends to overestimate the resolution-equivalent diameter for full-width-at-half-maximum resolution, whereas Anger's is a better approximation, but may produce underestimates for submillimeter resolution imagers, especially in the case of high-energy photons. For grazing incidence, both expressions may result in significant overestimates.

Mesh:

Year:  2004        PMID: 15191149     DOI: 10.1109/tmi.2004.826951

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  13 in total

1.  Analytic derivation of pinhole collimation sensitivity for a general source model using spherical harmonics.

Authors:  Yu-Sheng Li; James E Oldendick; Wei Chang
Journal:  Phys Med Biol       Date:  2010-04-19       Impact factor: 3.609

Review 2.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

3.  Investigation of imaging properties for submillimeter rectangular pinholes.

Authors:  Dan Xia; Stephen C Moore; Mi-Ae Park; Morgan Cervo; Scott D Metzler
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

Review 4.  The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging.

Authors:  Freek Beekman; Frans van der Have
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02       Impact factor: 9.236

5.  Multidivergent-beam stationary cardiac SPECT.

Authors:  Gengsheng L Zeng; Andrew M Stevens
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

6.  Design of a dual-resolution collimator for preclinical cardiac SPECT with a stationary triple-detector system.

Authors:  Stephen C Moore; Mi-Ae Park; Zhe Liu; Morgan C Lyon; Lindsay C Johnson; Victor H Lushear; James G Westberg; Scott D Metzler
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

7.  Onboard functional and molecular imaging: a design investigation for robotic multipinhole SPECT.

Authors:  James Bowsher; Susu Yan; Justin Roper; William Giles; Fang-Fang Yin
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

8.  A detector response function design in pinhole SPECT including geometrical calibration.

Authors:  Z El Bitar; R H Huesman; R Boutchko; Virgile Bekaert; David Brasse; G T Gullberg
Journal:  Phys Med Biol       Date:  2013-03-15       Impact factor: 3.609

9.  Improvement of Performance of Cardiac SPECT Camera Using Curved Detectors With Pinholes.

Authors:  Joyoni Dey
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-10       Impact factor: 1.679

10.  Multi-pinhole collimator design for small-object imaging with SiliSPECT: a high-resolution SPECT.

Authors:  S Shokouhi; S D Metzler; D W Wilson; T E Peterson
Journal:  Phys Med Biol       Date:  2008-12-16       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.