Literature DB >> 19505968

Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography.

F Tatsugami1, T Kanamoto, G Nakai, Y Takeda, H Morita, I Morinaga, S Yoshikawa, I Narabayashi.   

Abstract

The ability of short injection duration of contrast material to reduce the total injection volume in 64-detector row CT coronary angiography was investigated. 45 patients were divided into three groups: (i) those receiving 0.8 ml kg(-1) of contrast material (350 mgI ml(-1)) injected with a fixed duration of 14 s (Group A; n = 16); (ii) those receiving 0.8 ml kg(-1) of contrast material injected with a fixed duration of 10 s (Group B; n = 15); and (iii) those receiving 0.7 ml kg(-1) of contrast material injected with a fixed duration of 10 s (Group C; n = 14). All patients then received 20 ml of saline. Contrast densities of the ascending aorta and proximal and distal coronary arteries were assessed where vessel diameters were >2.0 mm. The mean enhancement value in the ascending aorta for Group B was significantly higher than that for Groups A and C (p<0.05), whereas there was no significant difference between Groups A and C. All enhancement values in the coronary arteries were higher than 250 Hounsfield units. The mean enhancement value for each coronary artery in Group B was significantly higher than that for Group A (p<0.05), whereas there was no significant difference between Groups A and C. In conclusion, a short injection duration allows a reduction in the total volume of contrast material from 0.8 ml kg(-1) to 0.7 ml kg(-1) while a steady contrast enhancement is maintained in the ascending aorta and coronary arteries.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19505968      PMCID: PMC3487251          DOI: 10.1259/bjr/23203690

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  15 in total

1.  Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography.

Authors:  S Achenbach; T Giesler; D Ropers; S Ulzheimer; H Derlien; C Schulte; E Wenkel; W Moshage; W Bautz; W G Daniel; W A Kalender; U Baum
Journal:  Circulation       Date:  2001-05-29       Impact factor: 29.690

2.  Optimal contrast application for cardiac 4-detector-row computed tomography.

Authors:  Christoph R Becker; Cheng Hong; Andreas Knez; Alexander Leber; Roland Bruening; U Joseph Schoepf; Maximilian F Reiser
Journal:  Invest Radiol       Date:  2003-11       Impact factor: 6.016

3.  Computed tomography coronary angiography with 370-millisecond gantry rotation time: evaluation of the best image reconstruction interval.

Authors:  Thorsten Alexander Bley; Nadir A Ghanem; Daniela Foell; Markus Uhl; Annette Geibel; Christoph Bode; Mathias Langer
Journal:  J Comput Assist Tomogr       Date:  2005 Jan-Feb       Impact factor: 1.826

Review 4.  Basics of cardiac MDCT: techniques and contrast application.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou
Journal:  Eur Radiol       Date:  2005-02       Impact factor: 5.315

5.  Advances in cardiac CT imaging: 64-slice scanner.

Authors:  Konstantin Nikolaou; Thomas Flohr; Andreas Knez; Carsten Rist; Bernd Wintersperger; Thorsten Johnson; Maximilian F Reiser; Christoph R Becker
Journal:  Int J Cardiovasc Imaging       Date:  2004-12       Impact factor: 2.357

6.  Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation.

Authors:  Filippo Cademartiri; Nico R Mollet; Aad van der Lugt; Eugene P McFadden; Theo Stijnen; Pim J de Feyter; Gabriel P Krestin
Journal:  Radiology       Date:  2005-08       Impact factor: 11.105

Review 7.  Contrast media nephropathy--how to diagnose and how to prevent?

Authors:  Richard Solomon
Journal:  Nephrol Dial Transplant       Date:  2007-04-20       Impact factor: 5.992

8.  Clinical use of multislice spiral computed tomography in 210 highly preselected patients: experience with 4 and 16 slice technology.

Authors:  T Beck; C Burgstahler; A Kuettner; A F Kopp; M Heuschmid; C D Claussen; S Schroeder
Journal:  Heart       Date:  2005-03-10       Impact factor: 5.994

9.  Contrast material-induced renal failure in patients with diabetes mellitus, renal insufficiency, or both. A prospective controlled study.

Authors:  P S Parfrey; S M Griffiths; B J Barrett; M D Paul; M Genge; J Withers; N Farid; P J McManamon
Journal:  N Engl J Med       Date:  1989-01-19       Impact factor: 91.245

10.  Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight.

Authors:  Kazuo Awai; Kumiko Hiraishi; Shinichi Hori
Journal:  Radiology       Date:  2004-01       Impact factor: 11.105

View more
  6 in total

1.  Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography.

Authors:  Tsuyoshi Isogai; Masahiro Jinzaki; Yutaka Tanami; Hiroyuki Kusuzaki; Minoru Yamada; Sachio Kuribayashi
Journal:  Jpn J Radiol       Date:  2011-01-26       Impact factor: 2.374

2.  Feasibility of contrast material volume reduction in coronary artery imaging using 320-slice volume CT.

Authors:  Patrick A Hein; Juliane May; Patrik Rogalla; Craig Butler; Bernd Hamm; Alexander Lembcke
Journal:  Eur Radiol       Date:  2009-12-17       Impact factor: 5.315

3.  ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group.

Authors:  Masahiro Jinzaki; Kakuya Kitagawa; I-Chen Tsai; Carmen Chan; Wei Yu; Hwan Seok Yong; Byoung Wook Choi
Journal:  Int J Cardiovasc Imaging       Date:  2010-10-08       Impact factor: 2.357

4.  Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography.

Authors:  Jie Liu; Jianbo Gao; Runze Wu; Yonggao Zhang; Lili Hu; Ping Hou
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-04       Impact factor: 2.357

5.  Novel contrast-injection protocol for coronary computed tomographic angiography: contrast-injection protocol customized according to the patient's time-attenuation response.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Shinichi Nakamura; Kazuo Awai; Daisuke Utsunomiya; Tomohiro Namimoto; Kazunori Harada; Yasuyuki Yamashita
Journal:  Heart Vessels       Date:  2013-03-20       Impact factor: 2.037

6.  High-pitch dual-source CT coronary angiography with low volumes of contrast medium.

Authors:  Alexander Lembcke; Carsten Schwenke; Patrick A Hein; Gesine Knobloch; Tahir Durmus; Bernd Hamm; Alexander Huppertz
Journal:  Eur Radiol       Date:  2013-08-15       Impact factor: 5.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.