The institutional review board approved this study, and all patients gave written informed consent. One hundred twenty-five patients scheduled to undergo retrospectively electrocardiographically gated 16-detector row computed tomographic coronary angiography were prospectively randomized into the following five groups with respect to the intravenous administration of a 140-mL bolus of contrast material at 4 mL/sec: group 1 (iohexol [300 mg of iodine per milliliter]), group 2 (iodixanol [320 mg I/mL]), group 3 (iohexol [350 mg I/mL]), group 4 (iomeprol [350 mg I/mL]), and group 5 (iomeprol [400 mg I/mL]). Attenuation was measured in the descending aorta and coronary arteries. One-way analysis of variance was used to compare groups. Mean attenuation values in the descending aorta were significantly (P < .05) lower in group 1 and higher in group 5 compared with the mean values in the other three groups. The same pattern was observed in the coronary arteries. Contrast materials with higher iodine concentrations yield significantly higher attenuation in the descending aorta and coronary arteries.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16040923     DOI: 10.1148/radiol.2362040468

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  48 in total

Review 1.  Right heart on multidetector CT.

Authors:  D Gopalan
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

Review 2.  Assessment of coronary blood flow with computed tomography and magnetic resonance imaging.

Authors:  Karl H Schuleri; Richard T George; Albert C Lardo
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

Review 3.  Quantitative and qualitative analysis and interpretation of CT perfusion imaging.

Authors:  Carolina Valdiviezo; Marietta Ambrose; Vishal Mehra; Albert C Lardo; Joao A C Lima; Richard T George
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

4.  Feasibility of low-concentration iodinated contrast medium with lower-tube-voltage dual-source CT aortography using iterative reconstruction: comparison with automatic exposure control CT aortography.

Authors:  Hee Jeong Shin; Song Soo Kim; Jae-Hwan Lee; Jae-Hyeong Park; Jin-Ok Jeong; Seon Ah Jin; Byung Seok Shin; Kyung-Sook Shin; Moonsang Ahn
Journal:  Int J Cardiovasc Imaging       Date:  2015-11-30       Impact factor: 2.357

Review 5.  Advances in stress cardiac MRI and computed tomography.

Authors:  Yasmin S Hamirani; Christopher M Kramer
Journal:  Future Cardiol       Date:  2013-09

6.  Attenuation values of the intracranial arterial and venous vessels by bolus injection of various contrast agents: a study with a single-detector helical CT scanner.

Authors:  Morio Nagahata; Yoshinao Abe; Shuichi Ono; Hikaru Yamaguchi; Hiroyuki Miura; Takashi Ohata; Fumiyasu Tsushima; Kohei Morimoto; Hiroko Seino
Journal:  Radiat Med       Date:  2007-04-27

7.  Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography.

Authors:  Filippo Cademartiri; Erica Maffei; Anselmo Alessandro Palumbo; Roberto Malagò; Ludovico La Grutta; W Bob Meiijboom; Annachiara Aldrovandi; Michele Fusaro; Luigi Vignali; Alberto Menozzi; Valerio Brambilla; Paolo Coruzzi; Massimo Midiri; Miles A Kirchin; Nico R A Mollet; Gabriel P Krestin
Journal:  Eur Radiol       Date:  2007-10-13       Impact factor: 5.315

8.  Increasing contrast agent concentration improves enhancement in first-pass CT perfusion.

Authors:  H M Silvennoinen; L M Hamberg; L Valanne; G J Hunter
Journal:  AJNR Am J Neuroradiol       Date:  2007-08       Impact factor: 3.825

9.  Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography.

Authors:  F Tatsugami; T Kanamoto; G Nakai; Y Takeda; H Morita; I Morinaga; S Yoshikawa; I Narabayashi
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

10.  Diagnosis of coronary artery disease in patients with atrial fibrillation using low tube voltage coronary CT angiography with isotonic low-concentration contrast agent.

Authors:  Yuning Pan; Qiuli Huang; Yingchao Zhu; Xinrong Zou; Huimin Chu; Xianfeng Du; Aijing Li; Shizhong Bu
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-30       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.