Literature DB >> 19472008

Incorporation of preprocedural PET into CT-guided radiofrequency ablation of hepatic metastases: a nonrigid image registration validation study.

Peng Lei1, Omkar Dandekar, David Widlus, Raj Shekhar.   

Abstract

This study evaluates the accuracy of augmenting initial intraprocedural computed tomography (CT) during radiofrequency ablation (RFA) of hepatic metastases with preprocedural positron emission tomography (PET) through a hardware-accelerated implementation of an automatic nonrigid PET-CT registration algorithm. The feasibility of augmenting intraprocedural CT with preprocedural PET to improve localization of CT-invisible but PET-positive tumors with images from actual RFA was explored. Preprocedural PET and intraprocedural CT images from 18 cases of hepatic RFA were included. All PET images in the study originated from a hybrid PET/CT scanner, and PET-CT registration was performed in two ways: (1) direct registration of preprocedural PET with intraprocedural CT and (2) indirect registration of preprocedural CT (i.e., the CT of hybrid PET/CT scan) with intraprocedural CT. A hardware-accelerated registration took approximately 2 min. Calculated registration errors were 7.0 and 8.4 mm for the direct and indirect methods, respectively. Overall, the direct registration was found to be statistically not distinct from that performed by a group of clinical experts. The accuracy, execution speed, and compactness of our implementation of nonrigid image registration suggest that existing PET can be overlaid on intraprocedural CT, promising a novel, technically feasible, and clinically viable approach for PET augmentation of CT guidance of RFA.

Entities:  

Mesh:

Year:  2009        PMID: 19472008      PMCID: PMC3046698          DOI: 10.1007/s10278-009-9204-x

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  38 in total

1.  PET-CT image registration in the chest using free-form deformations.

Authors:  David Mattes; David R Haynor; Hubert Vesselle; Thomas K Lewellen; William Eubank
Journal:  IEEE Trans Med Imaging       Date:  2003-01       Impact factor: 10.048

2.  Tissue deformation and shape models in image-guided interventions: a discussion paper.

Authors:  D J Hawkes; D Barratt; J M Blackall; C Chan; P J Edwards; K Rhode; G P Penney; J McClelland; D L G Hill
Journal:  Med Image Anal       Date:  2004-12-28       Impact factor: 8.545

Review 3.  Image-guided tumor ablation: standardization of terminology and reporting criteria.

Authors:  S Nahum Goldberg; Clement J Grassi; John F Cardella; J William Charboneau; Gerald D Dodd; Damian E Dupuy; Debra Gervais; Alice R Gillams; Robert A Kane; Fred T Lee; Tito Livraghi; John McGahan; David A Phillips; Hyunchul Rhim; Stuart G Silverman
Journal:  Radiology       Date:  2005-04-21       Impact factor: 11.105

4.  Incorporating CT, MR imaging, and positron emission tomography into minimally invasive therapies.

Authors:  Stephen B Solomon
Journal:  J Vasc Interv Radiol       Date:  2005-04       Impact factor: 3.464

5.  Accuracy of combined PET/CT in image-guided interventions of liver lesions: an ex-vivo study.

Authors:  Patrick Veit; Christiane Kuehle; Thomas Beyer; Hilmar Kuehl; Andreas Bockisch; Gerald Antoch
Journal:  World J Gastroenterol       Date:  2006-04-21       Impact factor: 5.742

6.  FPGA-Accelerated Deformable Image Registration for Improved Target-Delineation During CT-Guided Interventions.

Authors:  O Dandekar; R Shekhar
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2007-06       Impact factor: 3.833

7.  Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations.

Authors:  C R Meyer; J L Boes; B Kim; P H Bland; K R Zasadny; P V Kison; K Koral; K A Frey; R L Wahl
Journal:  Med Image Anal       Date:  1997-04       Impact factor: 8.545

8.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

9.  "Anatometabolic" tumor imaging: fusion of FDG PET with CT or MRI to localize foci of increased activity.

Authors:  R L Wahl; L E Quint; R D Cieslak; A M Aisen; R A Koeppe; C R Meyer
Journal:  J Nucl Med       Date:  1993-07       Impact factor: 10.057

Review 10.  Thermal ablative therapy for malignant liver tumors: a critical appraisal.

Authors:  Kelvin Kwok-Chai Ng; Chi-Ming Lam; Ronnie Tung-Ping Poon; Victor Ai; Wai-Kuen Tso; Sheung-Tat Fan
Journal:  J Gastroenterol Hepatol       Date:  2003-06       Impact factor: 4.029

View more
  6 in total

1.  Strategy for accurate liver intervention by an optical tracking system.

Authors:  Qinyong Lin; Rongqian Yang; Ken Cai; Peifeng Guan; Weihu Xiao; Xiaoming Wu
Journal:  Biomed Opt Express       Date:  2015-08-07       Impact factor: 3.732

2.  Real-time FDG PET guidance during biopsies and radiofrequency ablation using multimodality fusion with electromagnetic navigation.

Authors:  Aradhana M Venkatesan; Samuel Kadoury; Nadine Abi-Jaoudeh; Elliot B Levy; Roberto Maass-Moreno; Jochen Krücker; Sandeep Dalal; Sheng Xu; Neil Glossop; Bradford J Wood
Journal:  Radiology       Date:  2011-07-06       Impact factor: 11.105

Review 3.  The Role of PET Imaging Before, During, and After Percutaneous Hepatic and Pulmonary Tumor Ablation.

Authors:  Eric D McLoney; Ari J Isaacson; Patrick Keating
Journal:  Semin Intervent Radiol       Date:  2014-06       Impact factor: 1.513

4.  Real-time tracking of liver motion and deformation using a flexible needle.

Authors:  Peng Lei; Fred Moeslein; Bradford J Wood; Raj Shekhar
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-08-11       Impact factor: 2.924

5.  The Utility of Cloud Computing in Analyzing GPU-Accelerated Deformable Image Registration of CT and CBCT Images in Head and Neck Cancer Radiation Therapy.

Authors:  George Zaki; William Plishker; Wen Li; Junghoon Lee; Harry Quon; John Wong; Raj Shekhar
Journal:  IEEE J Transl Eng Health Med       Date:  2016-08-17       Impact factor: 3.316

6.  Software-based PET-MR image coregistration: combined PET-MRI for the rest of us!

Authors:  Matthew S Robertson; Xinyang Liu; William Plishker; George F Zaki; Pranav K Vyas; Nabile M Safdar; Raj Shekhar
Journal:  Pediatr Radiol       Date:  2016-07-05
  6 in total