Literature DB >> 15788601

The effect of single-detector CT versus MDCT on clinical outcomes in patients with suspected acute pulmonary embolism and negative results on CT pulmonary angiography.

John David Prologo1, Robert C Gilkeson, Mireya Diaz, Matthew Cummings.   

Abstract

OBJECTIVE: We sought to compare the clinical outcomes of patients in whom pulmonary embolism (PE) has been ruled out with single-detector CT versus MDCT, given the improved visualization of subsegmental clots with the latter and the recent increase in use of CT for evaluation of PE. SUBJECTS AND METHODS: Two cohorts of patients undergoing CT for suspected PE with either single-detector CT (3-mm collimation and pitch of 1.7) or MDCT (2-mm collimation and pitch of 1) scanners were prospectively observed and compared using predefined criteria for evidence of subsequent thromboembolic disease during the 6 months after the acquisition of their initial scan.
RESULTS: Ninety-eight patients were scanned using a single-detector CT scanner. Of these, none had evidence of subsequent PE or deep venous thrombosis (DVT), and six (6.1%) died of unrelated causes. Of the 100 patients scanned using an MDCT scanner, one (1.0%) had a subsequent nonfatal PE 2 months after the initial scanning, one (1.0%) had DVT 1 month after the initial scanning, and eight (8.0%) died of unrelated causes. No significant difference was found in either the probability of subsequent thromboembolic events (chi(2) = 0.3183, degrees of freedom [df] = 1, p = 1) or frequency of unrelated deaths (chi(2) = 0.2655, df = 1, p = 0.7829) between patients scanned using single-detector CT or MDCT protocols.
CONCLUSION: Our results show that patients with suspected acute PE and negative CT results have acceptable clinical outcomes in the absence of anticoagulation treatment up to 6 months after acquisition of their initial scan. Furthermore, we found that the increased visualization of smaller, more peripheral arteries afforded by multislice technology did not affect clinical outcome.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15788601     DOI: 10.2214/ajr.184.4.01841231

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  13 in total

1.  CTPA as the gold standard for the diagnosis of pulmonary embolism.

Authors:  Rosa M Estrada-Y-Martin; Sandra A Oldham
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-08-06       Impact factor: 2.924

2.  Prospective respiratory-triggered 64-slice CT pulmonary angiography for detection of pulmonary embolism--a feasibility study in a porcine model.

Authors:  Frank Oliver G Henes; Michael Groth; Marc Regier; Thorsten Bley; Hans-Dieter Nagel; Gerhard Adam; Philipp G C Begemann
Journal:  Emerg Radiol       Date:  2010-07-04

3.  Overdiagnosis of pulmonary embolism: evaluation of a hypoxia algorithm designed to avoid this catastrophic problem.

Authors:  Brian S Winters; Mark Solarz; Christina L Jacovides; James J Purtill; Richard H Rothman; Javad Parvizi
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  MDCT for suspected pulmonary embolism: multi-institutional survey of 16-MDCT data acquisition protocols.

Authors:  Pamela T Johnson; David Naidich; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2006-11-29

5.  Unsuspected pulmonary embolism on CT scanning: yet another headache for clinicians?

Authors:  Sujal R Desai
Journal:  Thorax       Date:  2007-06       Impact factor: 9.139

6.  Unsuspected pulmonary thromboemboli: a continuing clinical challenge.

Authors:  Herbert L Fred
Journal:  Tex Heart Inst J       Date:  2013

Review 7.  Diagnosis of pulmonary embolism with CT pulmonary angiography: a systematic review.

Authors:  K Hogg; G Brown; J Dunning; J Wright; S Carley; B Foex; K Mackway-Jones
Journal:  Emerg Med J       Date:  2006-03       Impact factor: 2.740

8.  MDCT of 220 consecutive patients with suspected acute pulmonary embolism: incidence of pulmonary embolism and of other acute or non-acute thoracic findings.

Authors:  S Tresoldi; Y H Kim; S P Baker; K Kandarpa
Journal:  Radiol Med       Date:  2008-07-09       Impact factor: 3.469

9.  Use of helical CT is associated with an increased incidence of postoperative pulmonary emboli in cancer patients with no change in the number of fatal pulmonary emboli.

Authors:  Rebecca C Auer; Allison R Schulman; Scott Tuorto; Mithat Gönen; Jaime Gonsalves; Larry Schwartz; Michelle S Ginsberg; Yuman Fong
Journal:  J Am Coll Surg       Date:  2009-05       Impact factor: 6.113

10.  Reduced Z-axis coverage multidetector CT angiography for suspected acute pulmonary embolism could decrease dose and maintain diagnostic accuracy.

Authors:  Joshua A Kallen; Bret F Coughlin; Michael T O'Loughlin; Barry Stein
Journal:  Emerg Radiol       Date:  2009-05-26
View more