Literature DB >> 19465294

Corneal topography with Scheimpflug imaging and videokeratography: comparative study of normal eyes.

Scott A Read1, Michael J Collins, D Robert Iskander, Brett A Davis.   

Abstract

PURPOSE: To compare the repeatability within anterior corneal topography measurements and agreement between measurements with the Pentacam HR rotating Scheimpflug camera and with a previously validated Placido disk-based videokeratoscope (Medmont E300).
SETTING: Contact Lens and Visual Optics Laboratory, School of Optometry, Queensland University of Technology, Brisbane, Queensland, Australia.
METHODS: Normal eyes in 101 young adult subjects had corneal topography measured using the Scheimpflug camera (6 repeated measurements) and videokeratoscope (4 repeated measurements). The best-fitting axial power corneal spherocylinder was calculated and converted into power vectors. Corneal higher-order aberrations (HOAs) (up to the 8th Zernike order) were calculated using the corneal elevation data from each instrument.
RESULTS: Both instruments showed excellent repeatability for axial power spherocylinder measurements (repeatability coefficients <0.25 diopter; intraclass correlation coefficients >0.9) and good agreement for all power vectors. Agreement between the 2 instruments was closest when the mean of multiple measurements was used in analysis. For corneal HOAs, both instruments showed reasonable repeatability for most aberration terms and good correlation and agreement for many aberrations (eg, spherical aberration, coma, higher-order root mean square). For other aberrations (eg, trefoil and tetrafoil), the 2 instruments showed relatively poor agreement.
CONCLUSIONS: For normal corneas, the Scheimpflug system showed excellent repeatability and reasonable agreement with a previously validated videokeratoscope for the anterior corneal axial curvature best-fitting spherocylinder and several corneal HOAs. However, for certain aberrations with higher azimuthal frequencies, the Scheimpflug system had poor agreement with the videokeratoscope; thus, caution should be used when interpreting these corneal aberrations with the Scheimpflug system.

Entities:  

Mesh:

Year:  2009        PMID: 19465294     DOI: 10.1016/j.jcrs.2009.01.020

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  23 in total

1.  [Scheimpflug photography of acute angle closure].

Authors:  J D Unterlauft; Y Yafai; P Wiedemann
Journal:  Ophthalmologe       Date:  2013-09       Impact factor: 1.059

2.  Keratometry with five different techniques: a study of device repeatability and inter-device agreement.

Authors:  Shiva Mehravaran; Soheila Asgari; Sara Bigdeli; Ashkan Shahnazi; Hassan Hashemi
Journal:  Int Ophthalmol       Date:  2014-02-23       Impact factor: 2.031

3.  Simulated Keratometry Repeatability in Subjects with and without Down Syndrome.

Authors:  Ayeswarya Ravikumar; Jason D Marsack; Julia S Benoit; Heather A Anderson
Journal:  Optom Vis Sci       Date:  2016-11       Impact factor: 1.973

4.  Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients.

Authors:  Sha-Sha Yu; Hui Song; Xin Tang
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

5.  Corneal aberrations and visual acuity after laser in situ keratomileusis: femtosecond laser versus mechanical microkeratome.

Authors:  Ramón Calvo; Jay W McLaren; David O Hodge; William M Bourne; Sanjay V Patel
Journal:  Am J Ophthalmol       Date:  2010-03-15       Impact factor: 5.258

6.  Effects of pterygium surgery on front and back corneal surfaces and anterior segment parameters.

Authors:  Ahmad Kheirkhah; Hamid Safi; Rahman Nazari; Reza Kaghazkanani; Hassan Hashemi; Mahmoud Jabbarvand Behrouz
Journal:  Int Ophthalmol       Date:  2012-04-07       Impact factor: 2.031

7.  Wound stability and surgically induced corneal astigmatism after transconjunctival single-plane sclerocorneal incision cataract surgery.

Authors:  Ken Hayashi; Soichiro Ogawa; Motoaki Yoshida; Koichi Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2016-10-06       Impact factor: 2.447

8.  Corneal topography from spectral optical coherence tomography (sOCT).

Authors:  Sergio Ortiz; Damian Siedlecki; Pablo Pérez-Merino; Noelia Chia; Alberto de Castro; Maciej Szkulmowski; Maciej Wojtkowski; Susana Marcos
Journal:  Biomed Opt Express       Date:  2011-11-04       Impact factor: 3.732

9.  A comprehensive assessment of the precision and agreement of anterior corneal power measurements obtained using 8 different devices.

Authors:  Qinmei Wang; Giacomo Savini; Kenneth J Hoffer; Zhen Xu; Yifan Feng; Daizong Wen; Yanjun Hua; Feng Yang; Chao Pan; Jinhai Huang
Journal:  PLoS One       Date:  2012-09-25       Impact factor: 3.240

10.  Quantitative OCT-based corneal topography in keratoconus with intracorneal ring segments.

Authors:  Sergio Ortiz; Pablo Pérez-Merino; Nicolas Alejandre; E Gambra; I Jimenez-Alfaro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2012-04-02       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.