Effects of pterygium surgery on front and back corneal surfaces and anterior segment parameters.

Ahmad Kheirkhah1, Hamid Safi, Rahman Nazari, Reza Kaghazkanani, Hassan Hashemi, Mahmoud Jabbarvand Behrouz.   

Abstract

The purpose of this study was to evaluate the effects of pterygium surgery on front and back corneal surfaces and anterior segment parameters. This prospective study included 96 eyes with primary pterygium that underwent surgery. Preoperatively and at 1, 3, and 6 months postoperatively, Pentacam was used to evaluate front and back corneal surfaces, anterior chamber depth (ACD), anterior chamber angle (ACA) and anterior chamber volume (ACV). Mean simulated keratometry at the front corneal surface increased from 42.73 ± 2.21 D preoperatively to 44.45 ± 2.05 D at 1 month (P < 0.001); it then decreased to 44.32 ± 2.07 D at 3 months (P < 0.001) and 44.19 ± 2.10 D at 6 months (P = 0.01). There was no statistically significant change in mean simulated keratometry at the back corneal surface. Radius of the front corneal best-fit sphere (BFS) decreased from 7.99 ± 0.29 mm preoperatively to 7.77 ± 0.25 mm at 1 month postoperatively (P < 0.001), without further change up to 6 months. Radius of the back corneal BFS increased from 6.42 ± 0.24 mm preoperatively to 6.50 ± 0.24 mm at 1 month (P < 0.001), without further change. Postoperative changes in mean simulated keratometry and radii of BFS had statistically significant positive correlations with pterygium extension onto the cornea and grade of pterygium morphology but, not with the surgical technique. There were no significant changes in ACD, ACA, and ACV values after pterygium surgery. Furthermore, the spherical equivalent of manifest refraction changed from +0.75 ± 1.06 D preoperatively to -0.72 ± 1.33 D at 1 month postoperatively (P = 0.001), with no further significant change. In conclusion, after pterygium surgery there were significant changes in front mean keratometry and front and back corneal radii of BFS. These were correlated with preoperative pterygium size and morphology grade. No significant changes in anterior segment parameters were noted postoperatively.

Entities:  

Mesh:

Year:  2012        PMID: 22484701     DOI: 10.1007/s10792-012-9560-2

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  31 in total

1.  The effects of pterygium surgery on refraction and corneal curvature.

Authors:  R H BEDROSSIAN
Journal:  Arch Ophthalmol       Date:  1960-10

2.  [Research on refraction and astigmatism of the cornea caused by pterygium].

Authors:  Z PAVISIC
Journal:  Ophthalmologica       Date:  1952-09       Impact factor: 3.250

3.  Comparison of Pentacam and Orbscan IIz on posterior curvature topography measurements in keratoconus eyes.

Authors:  Susannah Quisling; Stacy Sjoberg; Bridget Zimmerman; Kenneth Goins; John Sutphin
Journal:  Ophthalmology       Date:  2006-09       Impact factor: 12.079

4.  Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan.

Authors:  Birgit Lackner; Gerald Schmidinger; Christian Skorpik
Journal:  Optom Vis Sci       Date:  2005-09       Impact factor: 1.973

5.  Corneal changes after laser refractive surgery for myopia: comparison of Orbscan II and Pentacam findings.

Authors:  Hassan Hashemi; Shiva Mehravaran
Journal:  J Cataract Refract Surg       Date:  2007-05       Impact factor: 3.351

6.  Agreement between Pentacam and videokeratography in corneal power assessment.

Authors:  Giacomo Savini; Piero Barboni; Michele Carbonelli; Kenneth J Hoffer
Journal:  J Refract Surg       Date:  2009-06       Impact factor: 3.573

7.  Refractive change following pterygium surgery.

Authors:  K S Fong; V Balakrishnan; S P Chee; D T Tan
Journal:  CLAO J       Date:  1998-04

8.  Early and late effects of pterygium surgery on corneal topography.

Authors:  Murat Ozdemir; Adnan Cinal
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2005 Nov-Dec

9.  Conjunctival pterygia. Mechanism of corneal topographic changes.

Authors:  J B Oldenburg; J Garbus; J M McDonnell; P J McDonnell
Journal:  Cornea       Date:  1990-07       Impact factor: 2.651

10.  Corneal elevation and thickness in relation to the refractive status measured with the Pentacam Scheimpflug system.

Authors:  Omür O Uçakhan; Pelin Gesoğlu; Muhip Ozkan; Ayfer Kanpolat
Journal:  J Cataract Refract Surg       Date:  2008-11       Impact factor: 3.351

View more
  6 in total

1.  The effect of pterygium surgery on intraocular lens power and ocular biometric parameters.

Authors:  Emine Dogan; Burcin Cakir; Nilgun Ozkan Aksoy; Gürsoy Alagöz
Journal:  Ir J Med Sci       Date:  2021-11-13       Impact factor: 2.089

2.  The effect of limbal autograft location at primary pterygium excision on anterior and posterior corneal astigmatism: a comparative prospective study.

Authors:  Burcu Kazanci; Fatma Çorak Eroğlu; Emine Şen
Journal:  Int Ophthalmol       Date:  2022-01-23       Impact factor: 2.029

3.  Corneo-pterygium total area measurements utilising image analysis method.

Authors:  Hilmi Mohd Radzi; Mohd Kamal Khairidzan; Che Amin Mohd Zulfaezal; Esmady Ariffin Azrin
Journal:  J Optom       Date:  2019-05-13

4.  Time to Keratometric Stability After Pterygium Excision and the Associated Factors: A Clinical Perspective.

Authors:  Duangratn Niruthisard; Wasee Tulvatana; Vannarut Satitpitakul
Journal:  Clin Ophthalmol       Date:  2021-03-25

5.  Conjunctival Autograft With Fibrin Glue for Pterygium: A Long Term Recurrence Assessment.

Authors:  Pablo Luis Daponte; Andrea Cigna; Ovidio Lescano; Federico Sipowicz; Brenda Peña; Gabriel Abud; Gabriel Di-Virgilio; Adriana Chirinos; Gustavo Federico Bodino
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019-10-01

6.  Effect of Pterygium Removal Combined with Conjunctival Autograft on Corneal Parameters in Swept-Source Imaging.

Authors:  Marta P Wiącek; Monika Kuśmierz-Wojtasik; Bogna Kowalska; Anna Machalińska
Journal:  J Clin Med       Date:  2022-01-10       Impact factor: 4.241