Literature DB >> 19449384

Multiple repetition time balanced steady-state free precession imaging.

Tolga Cukur1, Dwight G Nishimura.   

Abstract

Although balanced steady-state free precession (bSSFP) imaging yields high signal-to-noise ratio (SNR) efficiency, the bright lipid signal is often undesirable. The bSSFP spectrum can be shaped to suppress the fat signal with scan-efficient alternating repetition time (ATR) bSSFP. However, the level of suppression is limited, and the pass-band is narrow due to its nonuniform shape. A multiple repetition time (TR) bSSFP scheme is proposed that creates a broad stop-band with a scan efficiency comparable with ATR-SSFP. Furthermore, the pass-band signal uniformity is improved, resulting in fewer shading/banding artifacts. When data acquisition occurs in more than a single TR within the multiple-TR period, the echoes can be combined to significantly improve the level of suppression. The signal characteristics of the proposed technique were compared with bSSFP and ATR-SSFP. The multiple-TR method generates identical contrast to bSSFP, and achieves up to an order of magnitude higher stop-band suppression than ATR-SSFP. In vivo studies at 1.5 T and 3 T demonstrate the superior fat-suppression performance of multiple-TR bSSFP. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19449384      PMCID: PMC2768767          DOI: 10.1002/mrm.21990

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  35 in total

1.  T(1) quantification with inversion recovery TrueFISP.

Authors:  K Scheffler; J Hennig
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Characterization and reduction of the transient response in steady-state MR imaging.

Authors:  B A Hargreaves; S S Vasanawala; J M Pauly; D G Nishimura
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

Review 3.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

4.  Rapid musculoskeletal MRI with phase-sensitive steady-state free precession: comparison with routine knee MRI.

Authors:  Shreyas S Vasanawala; Brian A Hargreaves; John M Pauly; Dwight G Nishimura; Christopher F Beaulieu; Garry E Gold
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

5.  S5FP: spectrally selective suppression with steady state free precession.

Authors:  J A Derbyshire; D A Herzka; E R McVeigh
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

6.  Intrinsic fat suppression in TIDE balanced steady-state free precession imaging.

Authors:  Dominik Paul; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

7.  Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging.

Authors:  Scott B Reeder; Angel R Pineda; Zhifei Wen; Ann Shimakawa; Huanzhou Yu; Jean H Brittain; Garry E Gold; Christopher H Beaulieu; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

Review 8.  Coronary magnetic resonance angiography.

Authors:  Matthias Stuber; Robert G Weiss
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

9.  Rapid Fourier imaging using steady-state free precession.

Authors:  R C Hawkes; S Patz
Journal:  Magn Reson Med       Date:  1987-01       Impact factor: 4.668

10.  Comparison of new sequences for high-resolution cartilage imaging.

Authors:  Brian A Hargreaves; Garry E Gold; Christopher F Beaulieu; Shreyas S Vasanawala; Dwight G Nishimura; John M Pauly
Journal:  Magn Reson Med       Date:  2003-04       Impact factor: 4.668

View more
  9 in total

1.  Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging.

Authors:  Holden H Wu; Paul T Gurney; Bob S Hu; Dwight G Nishimura; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

Review 2.  Magnetic resonance fingerprinting review part 2: Technique and directions.

Authors:  Debra F McGivney; Rasim Boyacıoğlu; Yun Jiang; Megan E Poorman; Nicole Seiberlich; Vikas Gulani; Kathryn E Keenan; Mark A Griswold; Dan Ma
Journal:  J Magn Reson Imaging       Date:  2019-07-25       Impact factor: 4.813

3.  On multiple alternating steady states induced by periodic spin phase perturbation waveforms.

Authors:  Giedrius T Buračas; Youngkyoo Jung; Jongho Lee; Richard B Buxton; Eric C Wong; Thomas T Liu
Journal:  Magn Reson Med       Date:  2011-08-08       Impact factor: 4.668

4.  The central signal singularity phenomenon in balanced SSFP and its application to positive-contrast imaging.

Authors:  R Reeve Ingle; Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2011-10-24       Impact factor: 4.668

5.  Small-tip fast recovery imaging using non-slice-selective tailored tip-up pulses and radiofrequency-spoiling.

Authors:  Jon-Fredrik Nielsen; Daehyun Yoon; Douglas C Noll
Journal:  Magn Reson Med       Date:  2012-04-17       Impact factor: 4.668

6.  ISMRM workshop on fat-water separation: insights, applications and progress in MRI.

Authors:  Houchun Harry Hu; Peter Börnert; Diego Hernando; Peter Kellman; Jingfei Ma; Scott Reeder; Claude Sirlin
Journal:  Magn Reson Med       Date:  2012-06-12       Impact factor: 4.668

7.  Noncontrast-enhanced renal angiography using multiple inversion recovery and alternating TR balanced steady-state free precession.

Authors:  Hattie Z Dong; Pauline W Worters; Holden H Wu; R Reeve Ingle; Shreyas S Vasanawala; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2012-11-21       Impact factor: 4.668

8.  Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively.

Authors:  Emeline J Ribot; Didier Wecker; Aurélien J Trotier; Benjamin Dallaudière; William Lefrançois; Eric Thiaudière; Jean-Michel Franconi; Sylvain Miraux
Journal:  PLoS One       Date:  2015-10-01       Impact factor: 3.240

9.  Magnetic resonance fingerprinting.

Authors:  Dan Ma; Vikas Gulani; Nicole Seiberlich; Kecheng Liu; Jeffrey L Sunshine; Jeffrey L Duerk; Mark A Griswold
Journal:  Nature       Date:  2013-03-14       Impact factor: 49.962

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.