Literature DB >> 3821484

Rapid Fourier imaging using steady-state free precession.

R C Hawkes, S Patz.   

Abstract

Reversal of the read gradient in a SSFP imaging experiment allows a full spin echo to be collected in the interval tau between successive rf pulses. Orthogonal gradient pulses are used to dephase and subsequently rephase the transverse magnetization each tau enabling 2D or 3D Fourier techniques. The minimum data collection time per slice in the 3D technique is 3.1 s (128 X 256). For a 2D data collection, an oscillating bipolar sawtooth gradient is used to select the slice. Each phase-encode value must be averaged over an equivalent portion of the oscillating slice-selection gradient and this condition gives a minimum of 25 s for 2D data collection. Excellent slice selection is achieved with less than 5% of the signal lying outside the slice profile central lobe. Images at 0.14 T show tissue contrast may be manipulated by changing the rf pulse angle, an example of which is the presence or absence of gray/white matter contrast at rf pulse angles of 30 and 90 degrees, respectively. The pulse angle theta dependence of five samples with different values of T2/T1 was measured and numerically calculated with good agreement between theory and experiment for theta less than or equal to 90 degrees.

Mesh:

Year:  1987        PMID: 3821484     DOI: 10.1002/mrm.1910040103

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Analytical solution and verification of diffusion effect in SSFP.

Authors:  C E Carney; S T Wong; S Patz
Journal:  Magn Reson Med       Date:  1991-06       Impact factor: 4.668

2.  Contrast-modified gradient echo imaging using rotary echo preparatory pulses.

Authors:  X P Zhu; P B Chilvers; C E Hutchinson; G A Morris; J M Hawnaur; J E Adams; C J Taylor
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

Review 3.  Rapid gradient-echo imaging.

Authors:  Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2012-10-23       Impact factor: 4.813

4.  Reevaluation of T2-weighted fast field echo (T2FFE): application to rapid volumetric black-blood imaging.

Authors:  Masami Yoneyama; Masanobu Nakamura; Takashi Tabuchi; Takashi Namiki; Atsushi Takemura; Makoto Obara
Journal:  Radiol Phys Technol       Date:  2013-02-16

Review 5.  Techniques and applications of in vivo diffusion imaging of articular cartilage.

Authors:  José G Raya
Journal:  J Magn Reson Imaging       Date:  2015-04-10       Impact factor: 4.813

6.  CEST-FISP: a novel technique for rapid chemical exchange saturation transfer MRI at 7 T.

Authors:  T Shah; L Lu; K M Dell; M D Pagel; M A Griswold; C A Flask
Journal:  Magn Reson Med       Date:  2010-10-11       Impact factor: 4.668

7.  Fat-water separation with alternating repetition time balanced SSFP.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

8.  Multiple repetition time balanced steady-state free precession imaging.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.