Literature DB >> 11284003

T(1) quantification with inversion recovery TrueFISP.

K Scheffler1, J Hennig.   

Abstract

A snapshot FLASH sequence can be used to acquire the time course of longitudinal magnetization during its recovery after a single inversion pulse. However, excitation pulses disturb the exponential recovery of longitudinal magnetization and may produce systematic errors in T(1) estimations. In this context the possibility of using the TrueFISP sequence to detect the recovery of longitudinal magnetization for quantitative T(1) measurements was examined. Experiments were performed on different Gd-doped water phantoms and on humans. T(1) values derived from inversion recovery TrueFISP were in excellent agreement with the single-point method even for flip angles up to 50 degrees. In terms of T(1) accuracy and SNR, the proposed method seems to be superior to the conventional inversion recovery snapshot FLASH technique. Magn Reson Med 45:720-723, 2001. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11284003     DOI: 10.1002/mrm.1097

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  38 in total

1.  Myocardial tagging with SSFP.

Authors:  Daniel A Herzka; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

Review 2.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

3.  Serial cardiac magnetic resonance imaging of injected mesenchymal stem cells.

Authors:  Jonathan M Hill; Alexander J Dick; Venkatesh K Raman; Richard B Thompson; Zu-Xi Yu; K Allison Hinds; Breno S S Pessanha; Michael A Guttman; Timothy R Varney; Bradley J Martin; Cynthia E Dunbar; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2003-08-11       Impact factor: 29.690

4.  Fast T1 mapping determined using incomplete inversion recovery look-locker 3D balanced SSFP acquisition and a simple two-parameter model fit.

Authors:  Neville D Gai; John A Butman
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

5.  Magnetic resonance coronary angiography with Vasovist: in-vivo T1 estimation to improve image quality of navigator and breath-hold techniques.

Authors:  Kai Nassenstein; Kai-Uwe Waltering; Sebastian Kelle; Thomas Schlosser; Frank Breuckmann; Stefan Maderwald; Peter Hunold; Eike Nagel; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2007-08-14       Impact factor: 5.315

6.  Effects of the nitric oxide donor JS-K on the blood-tumor barrier and on orthotopic U87 rat gliomas assessed by MRI.

Authors:  Claudia Weidensteiner; Wilfried Reichardt; Paul J Shami; Joseph E Saavedra; Larry K Keefer; Brunhilde Baumer; Anna Werres; Robert Jasinski; Nadja Osterberg; Astrid Weyerbrock
Journal:  Nitric Oxide       Date:  2013-01-28       Impact factor: 4.427

Review 7.  Cardiac T(1) imaging.

Authors:  Michael Jerosch-Herold; Raymond Y Kwong
Journal:  Top Magn Reson Imaging       Date:  2014-02

8.  An acetone-based phantom for quantitative diffusion MRI.

Authors:  Xiaoke Wang; Scott B Reeder; Diego Hernando
Journal:  J Magn Reson Imaging       Date:  2017-04-22       Impact factor: 4.813

9.  Multiple repetition time balanced steady-state free precession imaging.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

10.  DCE-MRI assessment of the effect of vandetanib on tumor vasculature in patients with advanced colorectal cancer and liver metastases: a randomized phase I study.

Authors:  Klaus Mross; Ulrike Fasol; Annette Frost; Robin Benkelmann; Jan Kuhlmann; Martin Büchert; Clemens Unger; Hubert Blum; Jürgen Hennig; Tsveta P Milenkova; Jean Tessier; Annetta D Krebs; Anderson J Ryan; Richard Fischer
Journal:  J Angiogenes Res       Date:  2009-09-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.