Literature DB >> 19406713

A 256 x 256 2-D array transducer with row-column addressing for 3-D rectilinear imaging.

Chi Hyung Seo1, Jesse T Yen.   

Abstract

We present simulation and experimental results from a 5-MHz, 256 x 256 2-D (65,536 elements, 38.4 x 38.4 mm) 2-D array transducer with row-column addressing. The main benefits of this design are a reduced number of interconnects, a modified transmit/receive switching scheme with a simple diode circuit, and an ability to perform volumetric imaging of targets near the transducer with transmit beamforming in azimuth and receive beamforming in elevation. The final dimensions of the transducer were 38.4 mm x 38.4 mm x 300 microm. After a row-column transducer was prototyped, the series resonance impedance was 104 Omega at 5.4 MHz. The measured -6 dB fractional bandwidth was 53% with a center frequency of 5.3 MHz. The SNR at the transmit focus was measured to be 30 dB. At 5 MHz, the average nearest neighbor crosstalk was -25 dB. In this paper, we present 3-D images of both 5 pairs of nylon wires embedded in a clear gelatin phantom and an 8 mm diameter cylindrical anechoic cyst phantom acquired from a 256 x 256 2-D array transducer made from a 1-3 composite. We display the azimuth and elevation B-scans as well as the C-scan for each image. The cross-section of the wires is visible in the azimuth B-scan, and the long axes can be seen in the elevation B-scan and C-scans. The pair of wires with 1-mm axial separation is discernible in the elevational B-scan. When a single wire from the wire target phantom was used, the measured lateral beamwidth was 0.68 mm and 0.70 mm at 30 mm depth in transmit beamforming and receive beamforming, respectively, compared with the simulated beamwidth of 0.55 mm. The cross-section of the cyst is visible in the azimuth B-scan whereas the long axes can be seen as a rectangle in the elevation B-scan and C-scans.

Entities:  

Mesh:

Year:  2009        PMID: 19406713      PMCID: PMC2894030          DOI: 10.1109/TUFFC.2009.1107

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  9 in total

1.  Three-dimensional ultrasound-guided core needle breast biopsy.

Authors:  W L Smith; K J Surry; G R Mills; D B Downey; A Fenster
Journal:  Ultrasound Med Biol       Date:  2001-08       Impact factor: 2.998

2.  Volumetric ultrasound imaging using 2-D CMUT arrays.

Authors:  Omer Oralkan; A Sanli Ergun; Ching-Hsiang Cheng; Jeremy A Johnson; Mustafa Karaman; Thomas H Lee; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

3.  Real-time rectilinear 3-D ultrasound using receive mode multiplexing.

Authors:  Jesse T Yen; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-02       Impact factor: 2.725

4.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

5.  Sparse 2-D array design for real time rectilinear volumetric imaging.

Authors:  J T Yen; J P Steinberg; S W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2000       Impact factor: 2.725

Review 6.  Mammography and early breast cancer detection.

Authors:  L W Bassett; D L Butler
Journal:  Am Fam Physician       Date:  1991-02       Impact factor: 3.292

7.  Registration of three-dimensional compound ultrasound scans of the breast for refraction and motion correction.

Authors:  A Moskalik; P L Carson; C R Meyer; J B Fowlkes; J M Rubin; M A Roubidoux
Journal:  Ultrasound Med Biol       Date:  1995       Impact factor: 2.998

8.  Ultrafast three-dimensional ultrasound: application to carotid artery imaging.

Authors:  C Palombo; M Kozakova; C Morizzo; F Andreuccetti; A Tondini; P Palchetti; G Mirra; G Parenti; N G Pandian
Journal:  Stroke       Date:  1998-08       Impact factor: 7.914

9.  A 256 x 256 2-D array transducer with row-column addressing for 3-D rectilinear imaging.

Authors:  Chi Hyung Seo; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-04       Impact factor: 2.725

  9 in total
  11 in total

1.  Sidelobe suppression in ultrasound imaging using dual apodization with cross-correlation.

Authors:  Chi Hyung Seo; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-10       Impact factor: 2.725

2.  Beamforming of sound from two-dimensional arrays using spatial matched filters.

Authors:  Jesse T Yen
Journal:  J Acoust Soc Am       Date:  2013-11       Impact factor: 1.840

3.  7.5 MHz dual-layer transducer array for 3-D rectilinear imaging.

Authors:  Yuling Chen; Man Nguyen; Jesse T Yen
Journal:  Ultrason Imaging       Date:  2011-07       Impact factor: 1.578

4.  A theranostic 3D ultrasound imaging system for high resolution image-guided therapy.

Authors:  Hanna Bendjador; Josquin Foiret; Robert Wodnicki; Douglas N Stephens; Zoe Krut; Eun-Yeong Park; Zulma Gazit; Dan Gazit; Gadi Pelled; Katherine W Ferrara
Journal:  Theranostics       Date:  2022-06-27       Impact factor: 11.600

5.  A dual-layer transducer array for 3-D rectilinear imaging.

Authors:  Jesse T Yen; Chi Hyung Seo; Samer I Awad; Jong S Jeong
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

6.  A 256 x 256 2-D array transducer with row-column addressing for 3-D rectilinear imaging.

Authors:  Chi Hyung Seo; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-04       Impact factor: 2.725

7.  3-D spatial compounding using a row-column array.

Authors:  Samer I Awad; Jesse T Yen
Journal:  Ultrason Imaging       Date:  2009-04       Impact factor: 1.578

8.  A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate.

Authors:  Jean L Sanders; Ali Onder Biliroglu; Xun Wu; Oluwafemi J Adelegan; Feysel Yalcin Yamaner; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

9.  A reconfigurable all-optical ultrasound transducer array for 3D endoscopic imaging.

Authors:  Erwin J Alles; Nora Fook Sheung; Sacha Noimark; Edward Z Zhang; Paul C Beard; Adrien E Desjardins
Journal:  Sci Rep       Date:  2017-04-26       Impact factor: 4.379

10.  The Design and Analysis of Split Row-Column Addressing Array for 2-D Transducer.

Authors:  Xu Li; Yanping Jia; Mingyue Ding; Ming Yuchi
Journal:  Sensors (Basel)       Date:  2016-09-27       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.