Literature DB >> 11527588

Three-dimensional ultrasound-guided core needle breast biopsy.

W L Smith1, K J Surry, G R Mills, D B Downey, A Fenster.   

Abstract

A new core needle breast biopsy system guided by 3-D ultrasound (US) is proposed. Our device provides rapid imaging and real-time guidance, as well as breast stabilization and a needle guidance apparatus using 3-D imaging. The targeting accuracy of our device was tested by inserting a 14-gauge biopsy needle into agar phantoms under 3-D US guidance. A total of 18 0.8-mm stainless-steel beads embedded in the phantoms defined each of the four target positions tested. Positioning accuracy was calculated by comparing needle tip position to the preinsertion bead position, as measured by three observers three times each on 3-D US. The interobserver standard error of measurement was no more than 0.14 mm for the beads and 0.27 mm for the needle tips. A 3-D principal component analysis was performed to obtain the population distribution of needle tip position relative to the target beads for the four target positions. The 3-D 95% confidence intervals were found to have total widths ranging from 0.43 to 1.71 mm, depending on direction and bead position.

Entities:  

Mesh:

Year:  2001        PMID: 11527588     DOI: 10.1016/s0301-5629(01)00396-9

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

1.  2-D array for 3-D ultrasound imaging using synthetic aperture techniques.

Authors:  Nadim M Daher; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-05       Impact factor: 2.725

2.  Three-dimensional ultrasound scanning.

Authors:  Aaron Fenster; Grace Parraga; Jeff Bax
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

Review 3.  Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review.

Authors:  Rongrong Guo; Guolan Lu; Binjie Qin; Baowei Fei
Journal:  Ultrasound Med Biol       Date:  2017-10-26       Impact factor: 2.998

4.  Three-dimensional ultrasound guidance of autonomous robotic breast biopsy: feasibility study.

Authors:  Kaicheng Liang; Albert J Rogers; Edward D Light; Daniel von Allmen; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2010-01       Impact factor: 2.998

5.  A dual-layer transducer array for 3-D rectilinear imaging.

Authors:  Jesse T Yen; Chi Hyung Seo; Samer I Awad; Jong S Jeong
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

6.  A 256 x 256 2-D array transducer with row-column addressing for 3-D rectilinear imaging.

Authors:  Chi Hyung Seo; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-04       Impact factor: 2.725

7.  Detection of focal liver lesions: from the subjectivity of conventional ultrasound to the objectivity of volume ultrasound.

Authors:  F Vecchiato; M D'Onofrio; R Malagò; E Martone; A Gallotti; N Faccioli; V Cantisani; C Marigliano; A Ruzzenente; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2009-06-23       Impact factor: 3.469

8.  Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification.

Authors:  G Sauer; H Deissler; K Strunz; G Helms; E Remmel; K Koretz; R Terinde; R Kreienberg
Journal:  Br J Cancer       Date:  2005-01-31       Impact factor: 7.640

9.  Interventional procedures in superficial lesions: the value of 2D with additional coronal reformatted 4D ultrasonography guidance.

Authors:  Cheng-Yen Chang; Hsin-Kai Wang; Hong-Jen Chiou; Yi-Hong Chou; Tain-Hsiung Chen; See-Ying Chiou
Journal:  Korean J Radiol       Date:  2006 Jan-Mar       Impact factor: 3.500