Literature DB >> 19363080

Viability PCR, a culture-independent method for rapid and selective quantification of viable Legionella pneumophila cells in environmental water samples.

Pilar Delgado-Viscogliosi1, Lydie Solignac, Jean-Marie Delattre.   

Abstract

PCR-based methods have been developed to rapidly screen for Legionella pneumophila in water as an alternative to time-consuming culture techniques. However, these methods fail to discriminate between live and dead bacteria. Here, we report a viability assay (viability PCR [v-PCR]) for L. pneumophila that combines ethidium monoazide bromide with quantitative real-time PCR (qPCR). The ability of v-PCR to differentiate viable from nonviable L. pneumophila cells was confirmed with permeabilizing agents, toluene, or isopropanol. v-PCR suppressed more than 99.9% of the L. pneumophila PCR signal in nonviable cultures and was able to discriminate viable cells in mixed samples. A wide range of physiological states, from culturable to dead cells, was observed with 64 domestic hot-water samples after simultaneous quantification of L. pneumophila cells by v-PCR, conventional qPCR, and culture methods. v-PCR counts were equal to or higher than those obtained by culture and lower than or equal to conventional qPCR counts. v-PCR was used to successfully monitor in vitro the disinfection efficacy of heating to 70 degrees C and glutaraldehyde and chlorine curative treatments. The v-PCR method appears to be a promising and rapid technique for enumerating L. pneumophila bacteria in water and, in comparison with conventional qPCR techniques used to monitor Legionella, has the advantage of selectively amplifying only viable cells.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19363080      PMCID: PMC2687295          DOI: 10.1128/AEM.02878-08

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  54 in total

1.  The use of multiple indices of physiological activity to access viability in chlorine disinfected Escherichia coli O157:H7.

Authors:  J T Lisle; B H Pyle; G A McFeters
Journal:  Lett Appl Microbiol       Date:  1999-07       Impact factor: 2.858

2.  Nucleic acid fluorochromes and flow cytometry prove useful in assessing the effect of chlorination on drinking water bacteria.

Authors:  Meng-Huot Phe; Manuel Dossot; Hélène Guilloteau; Jean-Claude Block
Journal:  Water Res       Date:  2005-09       Impact factor: 11.236

3.  Solid phase cytometry for detection of rare events.

Authors:  K Mignon-Godefroy; J G Guillet; C Butor
Journal:  Cytometry       Date:  1997-04-01

4.  Bacterial viability and antibiotic susceptibility testing with SYTOX green nucleic acid stain.

Authors:  B L Roth; M Poot; S T Yue; P J Millard
Journal:  Appl Environ Microbiol       Date:  1997-06       Impact factor: 4.792

5.  Rapid method for enumeration of viable Legionella pneumophila and other Legionella spp. in water.

Authors:  Pilar Delgado-Viscogliosi; Tristan Simonart; Virginie Parent; Grégory Marchand; Marie Dobbelaere; Eric Pierlot; Véronique Pierzo; Florence Menard-Szczebara; Elisabeth Gaudard-Ferveur; Karine Delabre; Jean Marie Delattre
Journal:  Appl Environ Microbiol       Date:  2005-07       Impact factor: 4.792

6.  Hypochlorous acid stress in Escherichia coli: resistance, DNA damage, and comparison with hydrogen peroxide stress.

Authors:  S Dukan; D Touati
Journal:  J Bacteriol       Date:  1996-11       Impact factor: 3.490

7.  Use of ethidium monoazide and PCR in combination for quantification of viable and dead cells in complex samples.

Authors:  Knut Rudi; Birgitte Moen; Signe Marie Drømtorp; Askild L Holck
Journal:  Appl Environ Microbiol       Date:  2005-02       Impact factor: 4.792

8.  Assessment of bacterial viability status by flow cytometry and single cell sorting.

Authors:  G N Caron; P Stephens; R A Badley
Journal:  J Appl Microbiol       Date:  1998-06       Impact factor: 3.772

9.  Detection of viable and dead Listeria monocytogenes on gouda-like cheeses by real-time PCR.

Authors:  K Rudi; K Naterstad; S M Drømtorp; H Holo
Journal:  Lett Appl Microbiol       Date:  2005       Impact factor: 2.858

10.  Effects of starvation on physiological activity and chlorine disinfection resistance in Escherichia coli O157:H7.

Authors:  J T Lisle; S C Broadaway; A M Prescott; B H Pyle; C Fricker; G A McFeters
Journal:  Appl Environ Microbiol       Date:  1998-12       Impact factor: 4.792

View more
  34 in total

1.  On-filter direct amplification of Legionella pneumophila for rapid assessment of its abundance and viability.

Authors:  Farag A Samhan; Tiffany M Stedtfeld; Hassan Waseem; Maggie R Williams; Robert D Stedtfeld; Syed A Hashsham
Journal:  Water Res       Date:  2017-05-13       Impact factor: 11.236

Review 2.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

3.  Application of EMA-qPCR as a complementary tool for the detection and monitoring of Legionella in different water systems.

Authors:  Tian Qin; Zhengan Tian; Hongyu Ren; Guangchun Hu; Haijian Zhou; Jinxing Lu; Chengwang Luo; Zunyu Liu; Zhujun Shao
Journal:  World J Microbiol Biotechnol       Date:  2012-01-05       Impact factor: 3.312

4.  Occurrence of Legionella in wastewater treatment plants linked to wastewater characteristics.

Authors:  C Caicedo; S Beutel; T Scheper; K H Rosenwinkel; R Nogueira
Journal:  Environ Sci Pollut Res Int       Date:  2016-07-04       Impact factor: 4.223

5.  Most probable number - loop mediated isothermal amplification (MPN-LAMP) for quantifying waterborne pathogens in <25min.

Authors:  Farhan Ahmad; Robert D Stedtfeld; Hassan Waseem; Maggie R Williams; Alison M Cupples; James M Tiedje; Syed A Hashsham
Journal:  J Microbiol Methods       Date:  2016-11-14       Impact factor: 2.363

6.  Prolonged survival of Campylobacter species in bovine manure compost.

Authors:  G Douglas Inglis; Tim A McAllister; Francis J Larney; Edward Topp
Journal:  Appl Environ Microbiol       Date:  2009-12-18       Impact factor: 4.792

7.  Specific real-time PCR for simultaneous detection and identification of Legionella pneumophila serogroup 1 in water and clinical samples.

Authors:  N Mérault; C Rusniok; S Jarraud; L Gomez-Valero; C Cazalet; M Marin; E Brachet; P Aegerter; J L Gaillard; J Etienne; J L Herrmann; C Lawrence; C Buchrieser
Journal:  Appl Environ Microbiol       Date:  2010-12-30       Impact factor: 4.792

8.  Catheterization of intestinal loops in ruminants does not adversely affect loop function.

Authors:  G Douglas Inglis; John P Kastelic; Richard R E Uwiera
Journal:  Comp Med       Date:  2010-12       Impact factor: 0.982

9.  Distribution of indigenous bacterial pathogens and potential pathogens associated with roof-harvested rainwater.

Authors:  P H Dobrowsky; M De Kwaadsteniet; T E Cloete; W Khan
Journal:  Appl Environ Microbiol       Date:  2014-01-31       Impact factor: 4.792

10.  Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures.

Authors:  Isabella Marchesi; Greta Ferranti; Antonella Mansi; Anna M Marcelloni; Anna R Proietto; Navneet Saini; Paola Borella; Annalisa Bargellini
Journal:  Appl Environ Microbiol       Date:  2016-05-02       Impact factor: 4.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.