Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures.

Isabella Marchesi1, Greta Ferranti2, Antonella Mansi3, Anna M Marcelloni3, Anna R Proietto3, Navneet Saini2, Paola Borella2, Annalisa Bargellini2.   

Abstract

Physical and chemical disinfection methods have been proposed with the aim of controlling Legionella water contamination. To date, the most effective procedures for reducing bacterial contamination have not yet been defined. The aim of this study was to assess the long-term effectiveness of various disinfection procedures in order to reduce both culturable and nonculturable (NC) legionellae in different hospital water networks treated with heat, chlorine dioxide, monochloramine, and hydrogen peroxide. The temperature levels and biocide concentrations that proved to give reliable results were analyzed. In order to study the possible effects on the water pipes, we verified the extent of corrosion on experimental coupons after applying each method for 6 months. The percentage of positive points was at its lowest after treatment with monochloramine, followed by chlorine dioxide, hydrogen peroxide, and hyperthermia. Different selections of Legionella spp. were observed, as networks treated with chlorine-based disinfectants were contaminated mainly by Legionella pneumophila serogroup 1, hyperthermia was associated with serogroups 2 to 14, and hydrogen peroxide treatment was associated mainly with non-pneumophila species. NC cells were detected only in heat-treated waters, and also when the temperature was approximately 60°C. The corrosion rates of the coupons were within a satisfactory limit for water networks, but the morphologies differed. We confirm here that chemical disinfection controls Legionella colonization more effectively than hyperthermia does. Monochloramine was the most effective treatment, while hydrogen peroxide may be a promising alternative to chlorine-based disinfectants due to its ability to select for other, less virulent or nonpathogenic species.
Copyright © 2016, American Society for Microbiology. All Rights Reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26969696      PMCID: PMC4959080          DOI: 10.1128/AEM.03873-15

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  34 in total

1.  Detection of Legionella pneumophila using a real-time PCR hybridization assay.

Authors:  A L Ballard; N K Fry; L Chan; S B Surman; J V Lee; T G Harrison; K J Towner
Journal:  J Clin Microbiol       Date:  2000-11       Impact factor: 5.948

2.  Persistence of the same strain of Legionella pneumophila in the water system of an Italian hospital for 15 years.

Authors:  M Scaturro; I Dell'eva; F Helfer; M L Ricci
Journal:  Infect Control Hosp Epidemiol       Date:  2007-07-03       Impact factor: 3.254

Review 3.  Controlling Legionella in hospital drinking water: an evidence-based review of disinfection methods.

Authors:  Yusen E Lin; Janet E Stout; Victor L Yu
Journal:  Infect Control Hosp Epidemiol       Date:  2011-02       Impact factor: 3.254

4.  Application of EMA-qPCR as a complementary tool for the detection and monitoring of Legionella in different water systems.

Authors:  Tian Qin; Zhengan Tian; Hongyu Ren; Guangchun Hu; Haijian Zhou; Jinxing Lu; Chengwang Luo; Zunyu Liu; Zhujun Shao
Journal:  World J Microbiol Biotechnol       Date:  2012-01-05       Impact factor: 3.312

Review 5.  Dead or alive: molecular assessment of microbial viability.

Authors:  Gerard A Cangelosi; John S Meschke
Journal:  Appl Environ Microbiol       Date:  2014-07-18       Impact factor: 4.792

6.  Control of Legionella contamination in a hospital water distribution system by monochloramine.

Authors:  Isabella Marchesi; Stefano Cencetti; Patrizia Marchegiano; Giuseppina Frezza; Paola Borella; Annalisa Bargellini
Journal:  Am J Infect Control       Date:  2011-07-08       Impact factor: 2.918

7.  Effectiveness of different methods to control legionella in the water supply: ten-year experience in an Italian university hospital.

Authors:  I Marchesi; P Marchegiano; A Bargellini; S Cencetti; G Frezza; M Miselli; P Borella
Journal:  J Hosp Infect       Date:  2010-12-04       Impact factor: 3.926

8.  Redox gradients in distribution systems influence water quality, corrosion, and microbial ecology.

Authors:  Sheldon Masters; Hong Wang; Amy Pruden; Marc A Edwards
Journal:  Water Res       Date:  2015-01-01       Impact factor: 11.236

9.  Compost facilities as a reservoir of Legionella pneumophila and other Legionella species.

Authors:  S Casati; L Conza; J Bruin; V Gaia
Journal:  Clin Microbiol Infect       Date:  2009-07-23       Impact factor: 8.067

10.  Molecular epidemiology of Legionella pneumophila serogroup 1 isolates following long-term chlorine dioxide treatment in a university hospital water system.

Authors:  B Casini; P Valentini; A Baggiani; F Torracca; S Frateschi; L Ceccherini Nelli; G Privitera
Journal:  J Hosp Infect       Date:  2008-04-24       Impact factor: 3.926

View more
  8 in total

Review 1.  Tenets of a holistic approach to drinking water-associated pathogen research, management, and communication.

Authors:  Caitlin Proctor; Emily Garner; Kerry A Hamilton; Nicholas J Ashbolt; Lindsay J Caverly; Joseph O Falkinham; Charles N Haas; Michele Prevost; D Rebecca Prevots; Amy Pruden; Lutgarde Raskin; Janet Stout; Sarah-Jane Haig
Journal:  Water Res       Date:  2021-12-22       Impact factor: 11.236

2.  Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment.

Authors:  Aaron J Prussin; David Otto Schwake; Linsey C Marr
Journal:  Build Environ       Date:  2017-06-13       Impact factor: 6.456

3.  Application of Hydrogen Peroxide as an Innovative Method of Treatment for Legionella Control in a Hospital Water Network.

Authors:  Beatrice Casini; Francesco Aquino; Michele Totaro; Mario Miccoli; Irio Galli; Laura Manfredini; Carlo Giustarini; Anna Laura Costa; Benedetta Tuvo; Paola Valentini; Gaetano Privitera; Angelo Baggiani
Journal:  Pathogens       Date:  2017-04-17

4.  The Impact of Storms on Legionella pneumophila in Cooling Tower Water, Implications for Human Health.

Authors:  Robin L Brigmon; Charles E Turick; Anna S Knox; Courtney E Burckhalter
Journal:  Front Microbiol       Date:  2020-12-10       Impact factor: 5.640

5.  The impact of pipeline changes and temperature increase in a hospital historically colonised with Legionella.

Authors:  S Quero; N Párraga-Niño; M Garcia-Núñez; M L Pedro-Botet; L Gavaldà; L Mateu; M Sabrià; J M Mòdol
Journal:  Sci Rep       Date:  2021-01-21       Impact factor: 4.379

Review 6.  Legionellosis Caused by Non-Legionella pneumophila Species, with a Focus on Legionella longbeachae.

Authors:  Stephen T Chambers; Sandy Slow; Amy Scott-Thomas; David R Murdoch
Journal:  Microorganisms       Date:  2021-01-31

7.  Risk assessment and quantitative measurement along with monitoring of Legionella in hospital water sources.

Authors:  S Bavari; S Mirkalantari; F Masjedian Jazi; D Darban-Sarokhalil; B Golnari Marani
Journal:  New Microbes New Infect       Date:  2021-12-24

8.  Advances in Legionella Control by a New Formulation of Hydrogen Peroxide and Silver Salts in a Hospital Hot Water Network.

Authors:  Luna Girolamini; Ada Dormi; Tiziana Pellati; Paolo Somaroli; Davide Montanari; Andrea Costa; Francesca Savelli; Andrea Martelli; Antonella Grottola; Giulia Fregni Serpini; Sandra Cristino
Journal:  Pathogens       Date:  2019-10-29
  8 in total