Literature DB >> 19326160

Design of internal MRI coils using ultimate intrinsic SNR.

Yiğitcan Eryaman1, Yusuf Oner, Ergin Atalar.   

Abstract

OBJECT: Internal MRI coils have important applications in diagnostic and interventional studies. Since they can be placed very close to the region of interest in the body, they are favored over external coils in applications where high-resolution images are required. In this paper it is demonstrated that ultimate intrinsic SNR (UISNR) and the optimum coil sensitivity solutions can be used to make new coil designs with higher intrinsic SNR.
MATERIALS AND METHODS: In this study, UISNR, which is the maximum attainable value of the intrinsic SNR, is used as a measure of performance and as a design criterion. As an example, a novel endorectal MRI coil is designed. The design is tested with phantom and patient studies.
RESULTS: An endorectal coil is built to demonstrate the effectiveness of the design strategy. ISNR of the endorectal coil approximates the UISNR to 72%.
CONCLUSION: An internal coil design method that takes advantage of the UISNR and optimum coil sensitivity calculations was presented. This method can also be used to design better internal MRI coils for different applications.

Entities:  

Mesh:

Year:  2009        PMID: 19326160     DOI: 10.1007/s10334-009-0167-1

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  13 in total

1.  Endourethral MRI.

Authors:  H H Quick; J M Serfaty; H K Pannu; R Genadry; C J Yeung; E Atalar
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

2.  Transesophageal magnetic resonance imaging.

Authors:  K A Shunk; J A Lima; A W Heldman; E Atalar
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

3.  Evaluation of internal MRI coils using ultimate intrinsic SNR.

Authors:  Haydar Celik; Yigitcan Eryaman; Ayhan Altintaş; I A Abdel-Hafez; Ergin Atalar
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

4.  Design of a novel MRI compatible manipulator for image guided prostate interventions.

Authors:  Axel Krieger; Robert C Susil; Cynthia Ménard; Jonathan A Coleman; Gabor Fichtinger; Ergin Atalar; Louis L Whitcomb
Journal:  IEEE Trans Biomed Eng       Date:  2005-02       Impact factor: 4.538

5.  Retrospective correction of intensity inhomogeneities in MRI.

Authors:  C R Meyer; P H Bland; J Pipe
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

6.  A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

Authors:  J G Sled; A P Zijdenbos; A C Evans
Journal:  IEEE Trans Med Imaging       Date:  1998-02       Impact factor: 10.048

7.  Ultimate intrinsic signal-to-noise ratio in MRI.

Authors:  O Ocali; E Atalar
Journal:  Magn Reson Med       Date:  1998-03       Impact factor: 4.668

8.  Intravascular magnetic resonance imaging using a loopless catheter antenna.

Authors:  O Ocali; E Atalar
Journal:  Magn Reson Med       Date:  1997-01       Impact factor: 4.668

9.  Prostate: MR imaging with an endorectal surface coil.

Authors:  M D Schnall; R E Lenkinski; H M Pollack; Y Imai; H Y Kressel
Journal:  Radiology       Date:  1989-08       Impact factor: 11.105

10.  Intravascular (catheter) NMR receiver probe: preliminary design analysis and application to canine iliofemoral imaging.

Authors:  G C Hurst; J Hua; J L Duerk; A M Cohen
Journal:  Magn Reson Med       Date:  1992-04       Impact factor: 4.668

View more
  4 in total

1.  Optothermal profile of an ablation catheter with integrated microcoil for MR-thermometry during Nd:YAG laser interstitial thermal therapies of the liver—an in-vitro experimental and theoretical study.

Authors:  Evdokia M Kardoulaki; Richard R A Syms; Ian R Young; Kaushal Choonee; Marc Rea; Wladyslaw M W Gedroyc
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

2.  In Vitro Intraductal MRI and T2 Mapping of Cholangiocarcinoma Using Catheter Coils.

Authors:  Narong Khuntikeo; Attapol Titapun; Nittaya Chamadol; Wuttisak Boonphongsathien; Prakasit Sa-Ngiamwibool; Simon D Taylor-Robinson; Christopher A Wadsworth; Shuo Zhang; Evdokia M Kardoulaki; Richard R A Syms
Journal:  Hepat Med       Date:  2020-07-27

3.  Intracardiac MR imaging (ICMRI) guiding-sheath with amplified expandable-tip imaging and MR-tracking for navigation and arrythmia ablation monitoring: Swine testing at 1.5 and 3T.

Authors:  Ehud J Schmidt; Gregory Olson; Junichi Tokuda; Akbar Alipour; Ronald D Watkins; Eric M Meyer; Hassan Elahi; William G Stevenson; Jeffrey Schweitzer; Charles L Dumoulin; Thomas Johnson; Aravindan Kolandaivelu; Wolfgang Loew; Henry R Halperin
Journal:  Magn Reson Med       Date:  2022-02-10       Impact factor: 3.737

4.  Improving the Detection of Cholangiocarcinoma: In vitro MRI-Based Study Using Local Coils and T2 Mapping.

Authors:  Narong Khuntikeo; Attapol Titapun; Nittaya Chamadol; Wuttisak Boonphongsathien; Prakasit Sa-Ngiamwibool; Simon D Taylor-Robinson; Christopher A Wadsworth; Shuo Zhang; Evdokia M Kardoulaki; Ian R Young; Richard R A Syms
Journal:  Hepat Med       Date:  2020-03-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.