Literature DB >> 19291968

A low-cost density reference phantom for computed tomography.

Zachary H Levine1, Mingdong Li, Anthony P Reeves, David F Yankelevitz, Joseph J Chen, Eliot L Siegel, Adele Peskin, Diana N Zeiger.   

Abstract

The authors characterized a commercially available foam composed of polyurethane and polyisocyanurate which is marketed for modeling parts in the aircraft, automotive, and related industries. The authors found that the foam may be suitable for use as a density reference standard in the range below -400 Hounsfield units. This range is coincident with the density of lung tissue. The foam may be helpful in making the diagnosis of lung disease more systematic.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19291968      PMCID: PMC2673671          DOI: 10.1118/1.3049596

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  A scanographic assessment of pulmonary morphology in acute lung injury. Significance of the lower inflection point detected on the lung pressure-volume curve.

Authors:  S R Vieira; L Puybasset; Q Lu; J Richecoeur; P Cluzel; P Coriat; J J Rouby
Journal:  Am J Respir Crit Care Med       Date:  1999-05       Impact factor: 21.405

2.  Standardization of low attenuation area versus total lung area in chest X-ray CT as an indicator of chronic pulmonary emphysema.

Authors:  M Mishima; T Hirai; Z Jin; Y Oku; N Sakai; Y Nakano; H Sakai; K Chin; M Ohi; K Kawakami; K Shimada; H Itoh; K Yamaguchi; T Sawa; K Kuno
Journal:  Front Med Biol Eng       Date:  1997

3.  Development of lung and soft tissue substitutes for photons.

Authors:  Sakae Kinase; Masaya Kimura; Hiroshi Noguchi; Sumi Yokoyama
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

4.  Lung nodule enhancement at CT: multicenter study.

Authors:  S J Swensen; R W Viggiano; D E Midthun; N L Müller; A Sherrick; K Yamashita; D P Naidich; E F Patz; T E Hartman; J R Muhm; A L Weaver
Journal:  Radiology       Date:  2000-01       Impact factor: 11.105

5.  Foamed epoxy resin-based lung substitutes.

Authors:  D R White; C Constantinou; R J Martin
Journal:  Br J Radiol       Date:  1986-08       Impact factor: 3.039

6.  CT densitometry of the lungs: scanner performance.

Authors:  G J Kemerink; R J Lamers; G R Thelissen; J M van Engelshoven
Journal:  J Comput Assist Tomogr       Date:  1996 Jan-Feb       Impact factor: 1.826

7.  Nobel Award address. Computed medical imaging.

Authors:  G N Hounsfield
Journal:  Med Phys       Date:  1980 Jul-Aug       Impact factor: 4.071

8.  Tissue-equivalent materials for construction of tomographic dosimetry phantoms in pediatric radiology.

Authors:  A K Jones; D E Hintenlang; W E Bolch
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

9.  Emphysema: effect of reconstruction algorithm on CT imaging measures.

Authors:  Kirsten L Boedeker; Michael F McNitt-Gray; Sarah R Rogers; Dao A Truong; Matthew S Brown; David W Gjertson; Jonathan G Goldin
Journal:  Radiology       Date:  2004-07       Impact factor: 11.105

10.  An automated method to assess the distribution of low attenuation areas on chest CT scans in chronic pulmonary emphysema patients.

Authors:  N Sakai; M Mishima; K Nishimura; H Itoh; K Kuno
Journal:  Chest       Date:  1994-11       Impact factor: 9.410

View more
  5 in total

1.  Standardizing CT lung density measure across scanner manufacturers.

Authors:  Huaiyu Heather Chen-Mayer; Matthew K Fuld; Bernice Hoppel; Philip F Judy; Jered P Sieren; Junfeng Guo; David A Lynch; Antonio Possolo; Sean B Fain
Journal:  Med Phys       Date:  2017-02-21       Impact factor: 4.071

2.  Tumor volume measurement error using computed tomography imaging in a phase II clinical trial in lung cancer.

Authors:  Claudia I Henschke; David F Yankelevitz; Rowena Yip; Venice Archer; Gudrun Zahlmann; Karthik Krishnan; Brian Helba; Ricardo Avila
Journal:  J Med Imaging (Bellingham)       Date:  2016-09-20

3.  Inter- and intra-scan variability for lung imaging quantifications via CT.

Authors:  Sachin S Shankar; Eric A Hoffman; Jarron Atha; Jessica C Sieren; Ehsan Samei; Ehsan Abadi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

4.  Scanner-specific validation of a CT simulator using a COPD-emulated anthropomorphic phantom.

Authors:  Sachin S Shankar; Giavanna L Jadick; Eric A Hoffman; Jarron Atha; Jessica C Sieren; Ehsan Samei; Ehsan Abadi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

5.  Preliminary X-ray CT investigation to link Hounsfield unit measurements with the International System of Units (SI).

Authors:  Zachary H Levine; Adele P Peskin; Andrew D Holmgren; Edward J Garboczi
Journal:  PLoS One       Date:  2018-12-20       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.