Literature DB >> 27660808

Tumor volume measurement error using computed tomography imaging in a phase II clinical trial in lung cancer.

Claudia I Henschke1, David F Yankelevitz2, Rowena Yip2, Venice Archer3, Gudrun Zahlmann4, Karthik Krishnan5, Brian Helba5, Ricardo Avila6.   

Abstract

To address the error introduced by computed tomography (CT) scanners when assessing volume and unidimensional measurement of solid tumors, we scanned a precision manufactured pocket phantom simultaneously with patients enrolled in a lung cancer clinical trial. Dedicated software quantified bias and random error in the [Formula: see text], and [Formula: see text] dimensions of a Teflon sphere and also quantified response evaluation criteria in solid tumors and volume measurements using both constant and adaptive thresholding. We found that underestimation bias was essentially the same for [Formula: see text], and [Formula: see text] dimensions using constant thresholding and had similar values for adaptive thresholding. The random error of these length measurements as measured by the standard deviation and coefficient of variation was 0.10 mm (0.65), 0.11 mm (0.71), and 0.59 mm (3.75) for constant thresholding and 0.08 mm (0.51), 0.09 mm (0.56), and 0.58 mm (3.68) for adaptive thresholding, respectively. For random error, however, [Formula: see text] lengths had at least a fivefold higher standard deviation and coefficient of variation than [Formula: see text] and [Formula: see text]. Observed [Formula: see text]-dimension error was especially high for some 8 and 16 slice CT models. Error in CT image formation, in particular, for models with low numbers of detector rows, may be large enough to be misinterpreted as representing either treatment response or disease progression.

Entities:  

Keywords:  calibration; computed tomography; measurement error; response evaluation criteria in solid tumors; volumetry

Year:  2016        PMID: 27660808      PMCID: PMC5028411          DOI: 10.1117/1.JMI.3.3.035505

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  10 in total

1.  Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation.

Authors:  D F Yankelevitz; A P Reeves; W J Kostis; B Zhao; C I Henschke
Journal:  Radiology       Date:  2000-10       Impact factor: 11.105

2.  An open-source toolkit for the volumetric measurement of CT lung lesions.

Authors:  Karthik Krishnan; Luis Ibanez; Wesley D Turner; Julien Jomier; Ricardo S Avila
Journal:  Opt Express       Date:  2010-07-05       Impact factor: 3.894

3.  The phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: practical tips, artifact examples, and pitfalls to avoid.

Authors:  Cynthia H McCollough; Michael R Bruesewitz; Michael F McNitt-Gray; Krista Bush; Thomas Ruckdeschel; J Thomas Payne; James A Brink; Robert K Zeman
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

4.  A low-cost density reference phantom for computed tomography.

Authors:  Zachary H Levine; Mingdong Li; Anthony P Reeves; David F Yankelevitz; Joseph J Chen; Eliot L Siegel; Adele Peskin; Diana N Zeiger
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

5.  Comparison of 1D, 2D, and 3D nodule sizing methods by radiologists for spherical and complex nodules on thoracic CT phantom images.

Authors:  Nicholas Petrick; Hyun J Grace Kim; David Clunie; Kristin Borradaile; Robert Ford; Rongping Zeng; Marios A Gavrielides; Michael F McNitt-Gray; Z Q John Lu; Charles Fenimore; Binsheng Zhao; Andrew J Buckler
Journal:  Acad Radiol       Date:  2014-01       Impact factor: 3.173

6.  Ordinal scoring of coronary artery calcifications on low-dose CT scans of the chest is predictive of death from cardiovascular disease.

Authors:  Joseph Shemesh; Claudia I Henschke; Dorith Shaham; Rowena Yip; Ali O Farooqi; Matthew D Cham; Dorothy I McCauley; Mildred Chen; James P Smith; Daniel M Libby; Mark W Pasmantier; David F Yankelevitz
Journal:  Radiology       Date:  2010-09-09       Impact factor: 11.105

7.  Management of lung nodules detected by volume CT scanning.

Authors:  Rob J van Klaveren; Matthijs Oudkerk; Mathias Prokop; Ernst T Scholten; Kristiaan Nackaerts; Rene Vernhout; Carola A van Iersel; Karien A M van den Bergh; Susan van 't Westeinde; Carlijn van der Aalst; Erik Thunnissen; Dong Ming Xu; Ying Wang; Yingru Zhao; Hester A Gietema; Bart-Jan de Hoop; Harry J M Groen; Geertruida H de Bock; Peter van Ooijen; Carla Weenink; Johny Verschakelen; Jan-Willem J Lammers; Wim Timens; Dik Willebrand; Aryan Vink; Willem Mali; Harry J de Koning
Journal:  N Engl J Med       Date:  2009-12-03       Impact factor: 91.245

8.  A correlative biomarker analysis of the combination of bevacizumab and carboplatin-based chemotherapy for advanced nonsquamous non-small-cell lung cancer: results of the phase II randomized ABIGAIL study (BO21015).

Authors:  Tony Mok; Vera Gorbunova; Erzsebet Juhasz; Barna Szima; Olga Burdaeva; Sergey Orlov; Chong-Jen Yu; Venice Archer; Magalie Hilton; Paul Delmar; Celine Pallaud; Martin Reck
Journal:  J Thorac Oncol       Date:  2014-06       Impact factor: 15.609

9.  New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1).

Authors:  E A Eisenhauer; P Therasse; J Bogaerts; L H Schwartz; D Sargent; R Ford; J Dancey; S Arbuck; S Gwyther; M Mooney; L Rubinstein; L Shankar; L Dodd; R Kaplan; D Lacombe; J Verweij
Journal:  Eur J Cancer       Date:  2009-01       Impact factor: 9.162

10.  A Low-Cost Fiducial Reference Phantom for Computed Tomography.

Authors:  Zachary H Levine; Steven Grantham; Daniel S Sawyer; Anthony P Reeves; David F Yankelevitz
Journal:  J Res Natl Inst Stand Technol       Date:  2008-12-01
  10 in total
  8 in total

Review 1.  Quality assurance and quantitative imaging biomarkers in low-dose CT lung cancer screening.

Authors:  Chara E Rydzak; Samuel G Armato; Ricardo S Avila; James L Mulshine; David F Yankelevitz; David S Gierada
Journal:  Br J Radiol       Date:  2017-10-27       Impact factor: 3.039

2.  Strategic Initiatives for Veterans with Lung Cancer.

Authors:  Drew Moghanaki; Michael Hagan
Journal:  Fed Pract       Date:  2020-08

3.  Simultaneous Estimation of Bias and Resolution in PET Images With a Long-Lived "Pocket" Phantom System.

Authors:  Paul E Kinahan; Darrin W Byrd; Brian Helba; Kristen A Wangerin; Xiaoxiao Liu; Joshua R Levy; Keith C Allberg; Karthik Krishnan; Ricardo S Avila
Journal:  Tomography       Date:  2018-03

Review 4.  Pulmonary nodule radiological diagnostic algorithm in lung cancer screening.

Authors:  Katarzyna Dziadziuszko; Edyta Szurowska
Journal:  Transl Lung Cancer Res       Date:  2021-02

5.  A flexible electronic strain sensor for the real-time monitoring of tumor regression.

Authors:  Alex Abramson; Carmel T Chan; Yasser Khan; Alana Mermin-Bunnell; Naoji Matsuhisa; Robyn Fong; Rohan Shad; William Hiesinger; Parag Mallick; Sanjiv Sam Gambhir; Zhenan Bao
Journal:  Sci Adv       Date:  2022-09-16       Impact factor: 14.957

6.  The impact of respiratory gating on improving volume measurement of murine lung tumors in micro-CT imaging.

Authors:  S J Blocker; M D Holbrook; Y M Mowery; D C Sullivan; C T Badea
Journal:  PLoS One       Date:  2020-02-25       Impact factor: 3.240

7.  The Regimen of Computed Tomography Screening for Lung Cancer: Lessons Learned Over 25 Years From the International Early Lung Cancer Action Program.

Authors:  Claudia I Henschke; Rowena Yip; Dorith Shaham; Javier J Zulueta; Samuel M Aguayo; Anthony P Reeves; Artit Jirapatnakul; Ricardo Avila; Drew Moghanaki; David F Yankelevitz
Journal:  J Thorac Imaging       Date:  2021-01       Impact factor: 5.528

8.  QIBA guidance: Computed tomography imaging for COVID-19 quantitative imaging applications.

Authors:  Ricardo S Avila; Sean B Fain; Chuck Hatt; Samuel G Armato; James L Mulshine; David Gierada; Mario Silva; David A Lynch; Eric A Hoffman; Frank N Ranallo; John R Mayo; David Yankelevitz; Raul San Jose Estepar; Raja Subramaniam; Claudia I Henschke; Alex Guimaraes; Daniel C Sullivan
Journal:  Clin Imaging       Date:  2021-02-25       Impact factor: 2.420

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.