Tissue-equivalent materials for construction of tomographic dosimetry phantoms in pediatric radiology.

A K Jones1, D E Hintenlang, W E Bolch.   

Abstract

Tissue equivalent materials have a variety of uses, including routine quality assurance and quality control in both diagnostic and therapeutic physics. They are frequently used in a research capacity to measure doses delivered to patients undergoing various therapeutic procedures. However, very few tissue equivalent materials have been developed for research use at the low photon energies encountered in diagnostic radiology. In this paper, we present a series of tissue-equivalent (TE) materials designed to radiographically mimic human tissue at diagnostic photon energies. These tissue equivalent materials include STES-NB (newborn soft tissue substitute), BTES-NB (newborn bone tissue substitute), LTES (newborn as well as a child/adult lung tissue substitute), STES (child/adult soft tissue substitute), and BTES (child/adult bone tissue substitute). In all cases, targeted reference elemental compositions are taken from those specified in the ORNL stylized computational model series. For each material, reference values of mass density, mass attenuation coefficients (10-150 keV), and mass energy-absorption coefficients (10-150 keV) were matched as closely as permitted by material selection and manufacturing constraints. Values of mu/rho and mu(en)/rho for the newborn TE materials are noted to have maximum deviations from their ORNL reference values of from 0 to -3% and from +2% to -3%, respectively, over the diagnostic energy range 10-150 keV. For the child/adult TE materials, these same maximal deviations of mu/rho and mu(en)/rho are from +1.5% to -3% and from +3% to -3%, respectively. Simple calculations of x-ray fluence attenuation under narrow-beam geometry using a 66 kVp spectrum typical of newborn CR radiographs indicate that the tissue-equivalent materials presented here yield estimates of absorbed dose at depth to within 3.6% for STES-NB, 3.2% for BTES-NB, and 1.2% for LTES of the doses assigned to reference newborn soft, bone, and lung tissue, respectively.

Entities:  

Mesh:

Year:  2003        PMID: 12945973     DOI: 10.1118/1.1592641

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis.

Authors:  Ciprian N Ionita; Brendan Loughran; Amit Jain; S N Swetadri Vasan; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-23

2.  Scattered Dose Calculations and Measurements in a Life-Like Mouse Phantom.

Authors:  David Welch; Leah Turner; Michael Speiser; Gerhard Randers-Pehrson; David J Brenner
Journal:  Radiat Res       Date:  2017-01-31       Impact factor: 2.841

3.  A low-cost density reference phantom for computed tomography.

Authors:  Zachary H Levine; Mingdong Li; Anthony P Reeves; David F Yankelevitz; Joseph J Chen; Eliot L Siegel; Adele Peskin; Diana N Zeiger
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

4.  Monte Carlo simulations of adult and pediatric computed tomography exams: validation studies of organ doses with physical phantoms.

Authors:  Daniel J Long; Choonsik Lee; Christopher Tien; Ryan Fisher; Matthew R Hoerner; David Hintenlang; Wesley E Bolch
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies.

Authors:  D Welch; A D Harken; G Randers-Pehrson; D J Brenner
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

6.  Parameters and computer software for the evaluation of mass attenuation and mass energy-absorption coefficients for body tissues and substitutes.

Authors:  Akintunde A Okunade
Journal:  J Med Phys       Date:  2007-07

7.  Comparison of computed tomography dose index in polymethyl methacrylate and nylon dosimetry phantoms.

Authors:  Supawitoo Sookpeng; Patsuree Cheebsumon; Thanyawee Pengpan; Colin Martin
Journal:  J Med Phys       Date:  2016 Jan-Mar

8.  Design and implementation of a prototype head and neck phantom for the performance evaluation of gamma imaging systems.

Authors:  Mohammed S Alqahtani; John E Lees; Sarah L Bugby; Piyal Samara-Ratna; Aik H Ng; Alan C Perkins
Journal:  EJNMMI Phys       Date:  2017-07-06

9.  Dose comparison between Gafchromic film, XiO, and Monaco treatment planning systems in a novel pelvic phantom that contains a titanium hip prosthesis.

Authors:  Nicholas Ade; F C P du Plessis
Journal:  J Appl Clin Med Phys       Date:  2017-07-25       Impact factor: 2.102

10.  Direct measurement of radiation exposure dose to individual organs during diagnostic computed tomography examination.

Authors:  Kazuta Yamashita; Kosaku Higashino; Hiroaki Hayashi; Kazuki Takegami; Fumio Hayashi; Yoshihiro Tsuruo; Koichi Sairyo
Journal:  Sci Rep       Date:  2021-03-08       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.