Literature DB >> 19289425

U-SPECT-II: An Ultra-High-Resolution Device for Molecular Small-Animal Imaging.

Frans van der Have1, Brendan Vastenhouw, Ruud M Ramakers, Woutjan Branderhorst, Jens O Krah, Changguo Ji, Steven G Staelens, Freek J Beekman.   

Abstract

UNLABELLED: We present a new rodent SPECT system (U-SPECT-II) that enables molecular imaging of murine organs down to resolutions of less than half a millimeter and high-resolution total-body imaging.
METHODS: The U-SPECT-II is based on a triangular stationary detector set-up, an XYZ stage that moves the animal during scanning, and interchangeable cylindric collimators (each containing 75 pinhole apertures) for both mouse and rat imaging. A novel graphical user interface incorporating preselection of the field of view with the aid of optical images of the animal focuses the pinholes to the area of interest, thereby maximizing sensitivity for the task at hand. Images are obtained from list-mode data using statistical reconstruction that takes system blurring into account to increase resolution.
RESULTS: For (99m)Tc, resolutions determined with capillary phantoms were smaller than 0.35 and 0.45 mm using the mouse collimator with 0.35- and 0.6-mm pinholes, respectively, and less than 0.8 mm using the rat collimator with 1.0-mm pinholes. Peak geometric sensitivity is 0.07% and 0.18% for the mouse collimator with 0.35- and 0.6-mm pinholes, respectively, and 0.09% for the rat collimator. Resolution with (111)In, compared with that with (99m)Tc, was barely degraded, and resolution with (125)I was degraded by about 10%, with some additional distortion. In vivo, kidney, tumor, and bone images illustrated that U-SPECT-II could be used for novel applications in the study of dynamic biologic systems and radiopharmaceuticals at the suborgan level.
CONCLUSION: Images and movies obtained with U-SPECT-II provide high-resolution radiomolecule visualization in rodents. Discrimination of molecule concentrations between adjacent volumes of about 0.04 microL in mice and 0.5 microL in rats with U-SPECT-II is readily possible.

Entities:  

Mesh:

Year:  2009        PMID: 19289425     DOI: 10.2967/jnumed.108.056606

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  73 in total

1.  Phantom experiments on a PSAPD-based compact gamma camera with submillimeter spatial resolution for small animal SPECT.

Authors:  Sangtaek Kim; Mickel McClish; Fares Alhassen; Youngho Seo; Kanai S Shah; Robert G Gould
Journal:  IEEE Trans Nucl Sci       Date:  2010-10       Impact factor: 1.679

Review 2.  Novel delivery strategies for glioblastoma.

Authors:  Jiangbing Zhou; Kofi-Buaku Atsina; Benjamin T Himes; Garth W Strohbehn; W Mark Saltzman
Journal:  Cancer J       Date:  2012 Jan-Feb       Impact factor: 3.360

Review 3.  A shift from cell cultures to creatures: in vivo imaging of small animals in experimental regenerative medicine.

Authors:  Anna J Studwell; Darrell N Kotton
Journal:  Mol Ther       Date:  2011-09-27       Impact factor: 11.454

4.  Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging.

Authors:  Keiichi Magota; Naoki Kubo; Yuji Kuge; Ken-Ichi Nishijima; Songji Zhao; Nagara Tamaki
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-12-10       Impact factor: 9.236

5.  Improved quantification in multiple-pinhole SPECT by anatomy-based reconstruction using microCT information.

Authors:  Christian Vanhove; Michel Defrise; Axel Bossuyt; Tony Lahoutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-09-30       Impact factor: 9.236

Review 6.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

7.  Investigation of imaging properties for submillimeter rectangular pinholes.

Authors:  Dan Xia; Stephen C Moore; Mi-Ae Park; Morgan Cervo; Scott D Metzler
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

8.  Performance evaluation of stationary and semi-stationary acquisition with a non-stationary small animal multi-pinhole SPECT system.

Authors:  Catharina Lange; Ivayla Apostolova; Mathias Lukas; Kai P Huang; Frank Hofheinz; Betina Gregor-Mamoudou; Winfried Brenner; Ralph Buchert
Journal:  Mol Imaging Biol       Date:  2013-11-09       Impact factor: 3.488

9.  Noninvasive 3-dimensional imaging of liver regeneration in a mouse model of hereditary tyrosinemia type 1 using the sodium iodide symporter gene.

Authors:  Raymond D Hickey; Shennen A Mao; Bruce Amiot; Lukkana Suksanpaisan; Amber Miller; Rebecca Nace; Jaime Glorioso; Michael K O'Connor; Kah Whye Peng; Yasuhiro Ikeda; Stephen J Russell; Scott L Nyberg
Journal:  Liver Transpl       Date:  2015-03-12       Impact factor: 5.799

10.  Improvement of Performance of Cardiac SPECT Camera Using Curved Detectors With Pinholes.

Authors:  Joyoni Dey
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-10       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.