Literature DB >> 19277750

Detection of the movement of the humerus during daily activity.

Brian Coley1, Brigitte M Jolles, Alain Farron, Kamiar Aminian.   

Abstract

A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory setting and then tested on 31 healthy volunteer subjects while carrying the ambulatory system during 8 h of their daily life. For each recording, the periods of sitting, standing and walking during daily activity were detected using an inertial sensor attached on the chest. During each period of daily activity the type of arm movement (flexion, abduction, internal/external rotation) its velocity and frequency (number of movement/hour) were estimated. The results showed that during the whole daily activity and for each activity (i.e. walking, sitting and walking) the frequency of internal/external rotation was significantly higher while the frequency of abduction was the lowest (P < 0.009). In spite of higher number of flexion, abduction and internal/external rotation in the dominant arm, we have not observed in our population a significant difference with the non-dominant arm, implying that in healthy subjects the arm dominance does not lie considerably on the number of movements. As expected, the frequency of the movement increased from sitting to standing and from standing to walking, while we provide a quantitative value of this change during daily activity. This study provides preliminary evidence that this system is a useful tool for objectively assessing upper-limb activity during daily activity. The results obtained with the healthy population could be used as control data to evaluate arm movement of patients with shoulder diseases during daily activity.

Entities:  

Mesh:

Year:  2009        PMID: 19277750     DOI: 10.1007/s11517-009-0464-x

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  11 in total

1.  3D shoulder position measurements using a six-degree-of-freedom electromagnetic tracking device.

Authors:  C.G.M. Meskers; H.M. Vermeulen; J.H. de Groot; F.C.T. van Der Helm; P.M. Rozing
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-06       Impact factor: 2.063

2.  Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly.

Authors:  Bijan Najafi; Kamiar Aminian; François Loew; Yves Blanc; Philippe A Robert
Journal:  IEEE Trans Biomed Eng       Date:  2002-08       Impact factor: 4.538

3.  A study of the external forces and moments at the shoulder and elbow while performing every day tasks.

Authors:  Ingram A Murray; Garth R Johnson
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-07       Impact factor: 2.063

4.  Reliability of force direction dependent EMG parameters of shoulder muscles for clinical measurements.

Authors:  Carel G M Meskers; Jurriaan H de Groot; Henk J Arwert; Leonard A Rozendaal; Piet M Rozing
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-11       Impact factor: 2.063

Review 5.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand.

Authors:  Ge Wu; Frans C T van der Helm; H E J DirkJan Veeger; Mohsen Makhsous; Peter Van Roy; Carolyn Anglin; Jochem Nagels; Andrew R Karduna; Kevin McQuade; Xuguang Wang; Frederick W Werner; Bryan Buchholz
Journal:  J Biomech       Date:  2005-05       Impact factor: 2.712

6.  Electromyographic analysis in patients with multidirectional shoulder instability during pull, forward punch, elevation and overhead throw.

Authors:  Arpád Illyés; Rita M Kiss
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-09-05       Impact factor: 4.342

7.  Arm position during daily activity.

Authors:  Brian Coley; Brigitte M Jolles; Alain Farron; Kamiar Aminian
Journal:  Gait Posture       Date:  2008-06-10       Impact factor: 2.840

8.  Outcome evaluation in shoulder surgery using 3D kinematics sensors.

Authors:  Brian Coley; Brigitte M Jolles; Alain Farron; Aline Bourgeois; François Nussbaumer; Claude Pichonnaz; Kamiar Aminian
Journal:  Gait Posture       Date:  2006-08-28       Impact factor: 2.840

9.  Ambulatory system for human motion analysis using a kinematic sensor: monitoring of daily physical activity in the elderly.

Authors:  Bijan Najafi; Kamiar Aminian; Anisoara Paraschiv-Ionescu; François Loew; Christophe J Büla; Philippe Robert
Journal:  IEEE Trans Biomed Eng       Date:  2003-06       Impact factor: 4.538

10.  Effect of supraspinatus deficiency on humerus translation and glenohumeral contact force during abduction.

Authors:  Alexandre Terrier; Adrian Reist; Arne Vogel; Alain Farron
Journal:  Clin Biomech (Bristol, Avon)       Date:  2007-03-23       Impact factor: 2.063

View more
  4 in total

1.  Shoulder biomechanics: today's consensus and tomorrow's perspectives.

Authors:  Andrea Giovanni Cutti; H E J DirkJan Veeger
Journal:  Med Biol Eng Comput       Date:  2009-04-25       Impact factor: 2.602

2.  Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses.

Authors:  C Quental; J Folgado; P R Fernandes; J Monteiro
Journal:  Med Biol Eng Comput       Date:  2014-11-02       Impact factor: 2.602

3.  The reliability of side to side measurements of upper extremity activity levels in healthy subjects.

Authors:  Miguel Acuna; Tal Amasay; Andrew R Karduna
Journal:  BMC Musculoskelet Disord       Date:  2010-07-22       Impact factor: 2.362

4.  Heightened clinical utility of smartphone versus body-worn inertial system for shoulder function B-B score.

Authors:  Claude Pichonnaz; Kamiar Aminian; Céline Ancey; Hervé Jaccard; Estelle Lécureux; Cyntia Duc; Alain Farron; Brigitte M Jolles; Nigel Gleeson
Journal:  PLoS One       Date:  2017-03-20       Impact factor: 3.240