The reliability of side to side measurements of upper extremity activity levels in healthy subjects.

Miguel Acuna1, Tal Amasay, Andrew R Karduna.   

Abstract

BACKGROUND: In both clinical and occupational settings, ambulatory sensors are becoming common for assessing all day measurements of arm motion. In order for the motion of a healthy, contralateral side to be used as a control for the involved side, the inherent side to side differences in arm usage must be minimal. The goal of the present study was to determine the reliability of side to side measurements of upper extremity activity levels in healthy subjects.
METHODS: Thirty two subjects with no upper extremity pathologies were studied. Each subject wore a triaxial accelerometer on both arms for three and a half hours. Motion was assessed using parameters previously reported in the literature. Side to side differences were compared with the intraclass correlation coefficient, standard error of the mean, minimal detectable change scores and a projected sample size analysis.
RESULTS: The variables were ranked based on their percentage of minimal detectable change scores and sample sizes needed for paired t-tests. The order of these rankings was found to be identical and the top ranked parameters were activity counts per hour (MDC% = 9.5, n = 5), jerk time (MDC% = 15.8, n = 8) and percent time above 30 degrees (MDC% = 34.7, n = 9).
CONCLUSIONS: In general, the mean activity levels during daily activities were very similar between dominant and non-dominant arms. Specifically, activity counts per hour, jerk time, and percent time above 30 degrees were found to be the variables most likely to reveal significant difference or changes in both individuals and groups of subjects. The use of ambulatory measurements of upper extremity activity has very broad uses for occupational assessments, musculoskeletal injuries of the shoulder, elbow, wrist and hand as well as neurological pathologies.

Entities:  

Mesh:

Year:  2010        PMID: 20650006      PMCID: PMC2914700          DOI: 10.1186/1471-2474-11-168

Source DB:  PubMed          Journal:  BMC Musculoskelet Disord        ISSN: 1471-2474            Impact factor:   2.362


  48 in total

1.  Differences in control of limb dynamics during dominant and nondominant arm reaching.

Authors:  R L Sainburg; D Kalakanis
Journal:  J Neurophysiol       Date:  2000-05       Impact factor: 2.714

2.  Impact of upper limb complex regional pain syndrome type 1 on everyday life measured with a novel upper limb-activity monitor.

Authors:  Fabiënne C Schasfoort; Johannes B J Bussmann; Annemarie M A J Zandbergen; Henk J Stam
Journal:  Pain       Date:  2003-01       Impact factor: 6.961

3.  Work related shoulder disorders: quantitative exposure-response relations with reference to arm posture.

Authors:  S W Svendsen; J P Bonde; S E Mathiassen; K Stengaard-Pedersen; L H Frich
Journal:  Occup Environ Med       Date:  2004-10       Impact factor: 4.402

4.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors.

Authors:  Andrea Giovanni Cutti; Andrea Giovanardi; Laura Rocchi; Angelo Davalli; Rinaldo Sacchetti
Journal:  Med Biol Eng Comput       Date:  2007-12-18       Impact factor: 2.602

5.  Estimation of upper-limb orientation based on accelerometer and gyroscope measurements.

Authors:  Rick A Hyde; Laurence P Ketteringham; Simon A Neild; Rosie S Jones
Journal:  IEEE Trans Biomed Eng       Date:  2008-02       Impact factor: 4.538

Review 6.  Quantifying variation in physical load using exposure-vs-time data.

Authors:  S E Mathiassen; J Winkel
Journal:  Ergonomics       Date:  1991-12       Impact factor: 2.778

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Intrarater reliability of CROM measurement of cervical spine active range of motion in persons with and without neck pain.

Authors:  James P Fletcher; William D Bandy
Journal:  J Orthop Sports Phys Ther       Date:  2008-10       Impact factor: 4.751

9.  Hand preference and age in the United States.

Authors:  A N Gilbert; C J Wysocki
Journal:  Neuropsychologia       Date:  1992-07       Impact factor: 3.139

10.  Reproducibility and minimal detectable change of three-dimensional kinematic analysis of reaching tasks in people with hemiparesis after stroke.

Authors:  Joanne M Wagner; Jennifer A Rhodes; Carolynn Patten
Journal:  Phys Ther       Date:  2008-03-06
View more
  4 in total

1.  Accelerometry as an objective measure of upper-extremity activity.

Authors:  Samuel Larrivée; Emma Avery; Jeff Leiter; Jason Old
Journal:  Med Biol Eng Comput       Date:  2021-01-07       Impact factor: 2.602

2.  Tri-axial accelerometer analysis techniques for evaluating functional use of the extremities.

Authors:  Wendy J Hurd; Melissa M Morrow; Kenton R Kaufman
Journal:  J Electromyogr Kinesiol       Date:  2013-04-30       Impact factor: 2.368

3.  Upper extremity function in the free living environment of adults with traumatic brachial plexus injuries.

Authors:  Christina M Webber; Alexander Y Shin; Kenton R Kaufman
Journal:  J Electromyogr Kinesiol       Date:  2019-05-23       Impact factor: 2.368

4.  Usability Evaluation of a VibroTactile Feedback System in Stroke Subjects.

Authors:  Jeremia P Held; Bart Klaassen; Bert-Jan F van Beijnum; Andreas R Luft; Peter H Veltink
Journal:  Front Bioeng Biotechnol       Date:  2017-01-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.