Literature DB >> 12814238

Ambulatory system for human motion analysis using a kinematic sensor: monitoring of daily physical activity in the elderly.

Bijan Najafi1, Kamiar Aminian, Anisoara Paraschiv-Ionescu, François Loew, Christophe J Büla, Philippe Robert.   

Abstract

A new method of physical activity monitoring is presented, which is able to detect body postures (sitting, standing, and lying) and periods of walking in elderly persons using only one kinematic sensor attached to the chest. The wavelet transform, in conjunction with a simple kinematics model, was used to detect different postural transitions (PTs) and walking periods during daily physical activity. To evaluate the system, three studies were performed. The method was first tested on 11 community-dwelling elderly subjects in a gait laboratory where an optical motion system (Vicon) was used as a reference system. In the second study, the system was tested for classifying PTs (i.e., lying-to-sitting, sitting-to-lying, and turning the body in bed) in 24 hospitalized elderly persons. Finally, in a third study monitoring was performed on nine elderly persons for 45-60 min during their daily physical activity. Moreover, the possibility-to-perform long-term monitoring over 12 h has been shown. The first study revealed a close concordance between the ambulatory and reference systems. Overall, subjects performed 349 PTs during this study. Compared with the reference system, the ambulatory system had an overall sensitivity of 99% for detection of the different PTs. Sensitivities and specificities were 93% and 82% in sit-to-stand, and 82% and 94% in stand-to-sit, respectively. In both first and second studies, the ambulatory system also showed a very high accuracy (> 99%) in identifying the 62 transfers or rolling out of bed, as well as 144 different posture changes to the back, ventral, right and left sides. Relatively high sensitivity (> 90%) was obtained for the classification of usual physical activities in the third study in comparison with visual observation. Sensitivities and specificities were, respectively, 90.2% and 93.4% in sitting, 92.2% and 92.1% in "standing + walking," and, finally, 98.4% and 99.7% in lying. Overall detection errors (as percent of range) were 3.9% for "standing + walking," 4.1% for sitting, and 0.3% for lying. Finally, overall symmetric mean average errors were 12% for "standing + walking," 8.2% for sitting, and 1.3% for lying.

Entities:  

Mesh:

Year:  2003        PMID: 12814238     DOI: 10.1109/TBME.2003.812189

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  124 in total

1.  Automatic individual calibration in fall detection--an integrative ambulatory measurement framework.

Authors:  Jian Liu; Thurmon E Lockhart
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-12-08       Impact factor: 1.763

2.  Accelerometer's position independent physical activity recognition system for long-term activity monitoring in the elderly.

Authors:  Adil Mehmood Khan; Young-Koo Lee; Sungyoung Lee; Tae-Seong Kim
Journal:  Med Biol Eng Comput       Date:  2010-11-04       Impact factor: 2.602

3.  Wearable pendant device monitoring using new wavelet-based methods shows daily life and laboratory gaits are different.

Authors:  Matthew A D Brodie; Milou J M Coppens; Stephen R Lord; Nigel H Lovell; Yves J Gschwind; Stephen J Redmond; Michael Benjamin Del Rosario; Kejia Wang; Daina L Sturnieks; Michela Persiani; Kim Delbaere
Journal:  Med Biol Eng Comput       Date:  2015-08-06       Impact factor: 2.602

4.  Wireless wearable range-of-motion sensor system for upper and lower extremity joints: a validation study.

Authors:  Yogaprakash Kumar; Shih-Cheng Yen; Arthur Tay; Wangwei Lee; Fan Gao; Ziyi Zhao; Jingze Li; Benjamin Hon; Tim Tian-Ma Xu; Angela Cheong; Karen Koh; Yee-Sien Ng; Effie Chew; Gerald Koh
Journal:  Healthc Technol Lett       Date:  2015-02-10

5.  Analysis and decomposition of accelerometric signals of trunk and thigh obtained during the sit-to-stand movement.

Authors:  W G M Janssen; J B J Bussmann; H L D Horemans; H J Stam
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

6.  Detection of the movement of the humerus during daily activity.

Authors:  Brian Coley; Brigitte M Jolles; Alain Farron; Kamiar Aminian
Journal:  Med Biol Eng Comput       Date:  2009-03-10       Impact factor: 2.602

7.  Geriatric rehabilitation after hip fracture. Role of body-fixed sensor measurements of physical activity.

Authors:  P Benzinger; U Lindemann; C Becker; K Aminian; M Jamour; S E Flick
Journal:  Z Gerontol Geriatr       Date:  2014-04       Impact factor: 1.281

8.  Novel wearable technology for assessing spontaneous daily physical activity and risk of falling in older adults with diabetes.

Authors:  Bijan Najafi; David G Armstrong; Jane Mohler
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

9.  Alterations in gait parameters with peripheral artery disease: The importance of pre-frailty as a confounding variable.

Authors:  Nima Toosizadeh; Hannah Stocker; Rebecca Thiede; Jane Mohler; Joseph L Mills; Bijan Najafi
Journal:  Vasc Med       Date:  2016-09-15       Impact factor: 3.239

10.  A Novel Methodology for Extracting and Evaluating Therapeutic Movements in Game-Based Motion Capture Rehabilitation Systems.

Authors:  Zhichao Yang; Mohammad H Rafiei; Alexis Hall; Caroline Thomas; Hali A Midtlien; Alexander Hasselbach; Hojjat Adeli; Lynne V Gauthier
Journal:  J Med Syst       Date:  2018-11-07       Impact factor: 4.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.