Arm position during daily activity.

Brian Coley1, Brigitte M Jolles, Alain Farron, Kamiar Aminian.   

Abstract

A new method of evaluation for functional assessment of the shoulder during daily activity is presented. An ambulatory system using inertial sensors attached on the humerus was used to detect the ability to work at a specific position of the shoulder. Nine arm positions were defined based on humerus elevation. The method was tested on 31 healthy volunteer subjects. First, we estimated the ability of the system to detect the different elevation angles and arm positions of each subject. Following that, we evaluated their arm positions during approximately 8h of daily activities. Each arm position was recognized with a good sensitivity (range 80-100%) and specificity (range 96-99%). During daily activity, we estimated the frequency (number/h) that the humerus reached each arm position during the periods of 0-1s (period P1), 1-5s (period P2) and 5-30s (period P3). Our data showed that all subjects had 96% of their arm position reached under the 5th level (100-120 degrees ). No significant difference was observed between dominant and non-dominant sides for the frequency and duration of arm positions (p>0.3). Our evaluation was in accordance with the clinical questionnaire (the Constant score) for the P1 duration, but differed for longer periods P2 and P3. By quantifying the arm positions and their durations for both shoulders, we proposed a new score to evaluate the ability to work at a specific level based on the symmetry index of the arms activity. Using this score, we obtained, on average, good symmetry for healthy subjects. This score can be useful in evaluating the asymmetry in arm function in patients with a shoulder disease. The proposed technique could be used in a number of shoulder diseases where problems in performing daily activities should be expressed in terms of objective measure of arm position.

Entities:  

Mesh:

Year:  2008        PMID: 18547809     DOI: 10.1016/j.gaitpost.2008.04.014

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  7 in total

1.  Detection of the movement of the humerus during daily activity.

Authors:  Brian Coley; Brigitte M Jolles; Alain Farron; Kamiar Aminian
Journal:  Med Biol Eng Comput       Date:  2009-03-10       Impact factor: 2.602

2.  Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses.

Authors:  C Quental; J Folgado; P R Fernandes; J Monteiro
Journal:  Med Biol Eng Comput       Date:  2014-11-02       Impact factor: 2.602

3.  The reliability of side to side measurements of upper extremity activity levels in healthy subjects.

Authors:  Miguel Acuna; Tal Amasay; Andrew R Karduna
Journal:  BMC Musculoskelet Disord       Date:  2010-07-22       Impact factor: 2.362

4.  Assessing Shoulder Biomechanics of Healthy Elderly Individuals During Activities of Daily Living Using Inertial Measurement Units: High Maximum Elevation Is Achievable but Rarely Used.

Authors:  Ryan M Chapman; Michael T Torchia; John-Erik Bell; Douglas W Van Citters
Journal:  J Biomech Eng       Date:  2019-04-01       Impact factor: 2.097

5.  Upper extremity function in the free living environment of adults with traumatic brachial plexus injuries.

Authors:  Christina M Webber; Alexander Y Shin; Kenton R Kaufman
Journal:  J Electromyogr Kinesiol       Date:  2019-05-23       Impact factor: 2.368

6.  Three-dimensional alignment of the upper extremity in the standing neutral position in healthy subjects.

Authors:  Yuki Yoshida; Noboru Matsumura; Yoshitake Yamada; Satoshi Hiraga; Kazunori Ishii; Satoshi Oki; Yoichi Yokoyama; Minoru Yamada; Masaya Nakamura; Takeo Nagura; Masahiro Jinzaki
Journal:  J Orthop Surg Res       Date:  2022-04-15       Impact factor: 2.677

7.  Systematic review on the application of wearable inertial sensors to quantify everyday life motor activity in people with mobility impairments.

Authors:  Fabian Marcel Rast; Rob Labruyère
Journal:  J Neuroeng Rehabil       Date:  2020-11-04       Impact factor: 4.262

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.