Different-sized incisions for phacoemulsification in age-related cataract.

Chongfei Jin1, Xinyi Chen, Andrew Law, Yunhee Kang, Xue Wang, Wen Xu, Ke Yao.   

Abstract

BACKGROUND: Age-related cataract is the principal cause of blindness and visual impairment in the world. Phacoemulsification is the main surgical procedure used to treat cataract. The comparative effectiveness and safety of different-sized incisions for phacoemulsification has not been determined.
OBJECTIVES: The aim of this systematic review was to assess the effectiveness and safety of smaller versus larger incisions for phacoemulsification in age-related cataract. The primary outcome of this review was surgically induced astigmatism at three months after surgery. SEARCH
METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 10), MEDLINE Ovid (1946 to 28 October 2016), Embase Ovid (1947 to 28 October 2016), PubMed (1948 to 28 October 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 28 October 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 13 May 2013), ClinicalTrials.gov (www.clinicaltrials.gov; searched 28 October 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp; searched 28 October 2016). We did not use any date or language restrictions in the electronic searches for trials. SELECTION CRITERIA: We included randomized controlled trials (RCTs) comparing different-sized incisions in people with age-related cataract undergoing phacoemulsification. DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane. MAIN
RESULTS: We included 26 RCTs with a total of 2737 participants (3120 eyes). These trials were conducted in Bosnia and Herzegovina, China, France, India, Italy, Korea, Spain, Switzerland, and Turkey. Half of the 26 trials were conducted in China. We judged all trials as mostly at unclear to low risk of bias. The included RCTs compared four different-sized incisions:<= 1.5 mm, 1.8 mm, 2.2 mm, and approximately 3.0 mm. These incisions were performed using three different techniques: coaxial and biaxial microincision phacoemulsification (C-MICS and B-MICS) and standard phacoemulsification. Not all studies provided data in a form that could be included in this review. Five studies had three arms.Fifteen trials compared C-MICS (2.2 mm) with standard phacoemulsification (about 3.0 mm). Very low-certainty evidence suggested less surgically induced astigmatism in the C-MICS group at three months compared with standard phacoemulsification (mean difference (MD) -0.19 diopters (D), 95% confidence interval (CI) -0.30 to -0.09; 996 eyes; 8 RCTs). There was low-certainty evidence that both groups achieved similar best-corrected visual acuity (MD 0.00 logMAR, 95% CI -0.02 to 0.02; 242 eyes; 3 RCTs). There was low-certainty evidence of little or no difference in endothelial cell loss and central corneal thickness comparing C-MICS with standard phacoemulsification (MD -7.23 cells/mm2, 95% CI -78.66 to 64.20; 596 eyes; 4 RCTs) and (MD -0.68 μm, 95% CI -3.26 to 1.90; 487 eyes; 5 RCTs).Nine trials compared C-MICS (1.8 mm) with standard phacoemulsification (about 3.0 mm). Very low-certainty evidence suggested less astigmatism at three months in the C-MICS group compared with standard phacoemulsification group (MD -0.23 D, 95% CI -0.34 to -0.13; 561 eyes; 5 RCTs). Low-certainty evidence suggested little or no difference in best-corrected visual acuity, endothelial cell loss, and central corneal thickness in the two groups at three months (MD -0.02 logMAR, 95% CI -0.03 to -0.00; 192 eyes; 3 RCTs), (MD 7.56 cells/mm2, 95% CI -67.65 to 82.77; 380 eyes; 5 RCTs), and (MD -1.52 μm, 95% CI -6.29 to 3.25; 245 eyes; 3 RCTs).Six studies compared C-MICS (1.8 mm) with C-MICS (2.2 mm). There was low-certainty evidence that astigmatism, visual acuity, and central corneal thickness were similar in the two groups at three months (MD 0.04 D, 95% CI -0.09 to 0.16; 259 eyes; 3 RCTs), (MD 0.01 logMAR, 95% CI -0.01 to 0.04; 200 eyes; 3 RCTs), and (MD 0.45 μm, 95% CI -2.70 to 3.60; 100 eyes; 1 RCT). Very low-certainty evidence suggested higher endothelial cell loss in the 1.8 mm group (MD 213.00 cells/mm2, 95% CI 11.15 to 414.85; 70 eyes; 1 RCT).Four studies compared B-MICS (<= 1.5 mm) with standard phacoemulsification (about 3.0 mm). Astigmatism was similar in the two groups at three months (MD -0.01 D, 95% CI -0.03 to 0.01; 368 eyes; 2 RCTs; moderate-certainty evidence). There was low-certainty evidence on visual acuity, suggesting little or no difference between the two groups (MD -0.02 logMAR, 95% CI -0.04 to -0.00; 464 eyes; 3 RCTs). Low-certainty evidence on endothelial cell loss and central corneal thickness also suggested little or no difference between the two groups (MD 55.83 cells/mm2, 95% CI -34.93 to 146.59; 280 eyes; 1 RCT) and (MD 0.10 μm, 95% CI -14.04 to 14.24; 90 eyes; 1 RCT).None of the trials reported on quality of life. One trial reported that no participants experienced endophthalmitis or posterior capsule rupture; they also reported little or no difference between incision groups regarding corneal edema (risk ratio 1.02, 95% CI 0.40 to 2.63; 362 eyes). AUTHORS'
CONCLUSIONS: Phacoemulsification with smaller incisions was not consistently associated with less surgically induced astigmatism compared with phacoemulsification with larger incisions. Coaxial microincision phacoemulsification may be associated with less astigmatism than standard phacoemulsification, but the difference was small, in the order of 0.2 D, and the evidence was uncertain. Safety outcomes and quality of life were not adequately reported; these should be addressed in future studies.

Entities:  

Mesh:

Year:  2017        PMID: 28931202      PMCID: PMC5665700          DOI: 10.1002/14651858.CD010510.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  71 in total

1.  [Clinical evaluation on the coaxial 1.8 mm microincision cataract surgery].

Authors:  Ke Yao; Wei Wang; Wei Wu; Xia-jing Tang; Zhao-chun Li; Chong-fei Jin
Journal:  Zhonghua Yan Ke Za Zhi       Date:  2011-10

2.  Coaxial, microcoaxial, and biaxial microincision cataract surgery: prospective comparative study.

Authors:  Izzet Can; Tamer Takmaz; Yelda Yildiz; Hasan Ali Bayhan; Gülizar Soyugelen; Başak Bostanci
Journal:  J Cataract Refract Surg       Date:  2010-05       Impact factor: 3.351

3.  Microcoaxial phacoemulsification Part 2: clinical study.

Authors:  Robert H Osher
Journal:  J Cataract Refract Surg       Date:  2007-03       Impact factor: 3.351

4.  Anterior segment optical coherence tomography evaluation and comparison of main clear corneal incisions in microcoaxial and biaxial cataract surgery.

Authors:  Izzet Can; Hasan Ali Bayhan; Hale Celik; Başak Bostancı Ceran
Journal:  J Cataract Refract Surg       Date:  2011-03       Impact factor: 3.351

5.  Biaxial microincision versus coaxial small-incision clear cornea cataract surgery.

Authors:  Sabine Kurz; Frank Krummenauer; Pia Gabriel; N Pfeiffer; H Burkhard Dick
Journal:  Ophthalmology       Date:  2006-10       Impact factor: 12.079

6.  Corneal Optical Quality Following Sub 1.8 mm Micro-Incision Cataract Surgery vs. 2.2 mm Mini-Incision Coaxial Phacoemulsification.

Authors:  Jorge L Alió; Bassam Elkady; Dolores Ortiz
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

7.  Microcoaxial cataract surgery outcomes: comparison of 1.8 mm system and 2.2 mm system.

Authors:  Kyung-Min Lee; Hyung-Goo Kwon; Choun-Ki Joo
Journal:  J Cataract Refract Surg       Date:  2009-05       Impact factor: 3.351

8.  Intraindividual comparative study of corneal and ocular wavefront aberrations after biaxial microincision versus coaxial small-incision cataract surgery.

Authors:  A Denoyer; L Denoyer; D Marotte; M Georget; P-J Pisella
Journal:  Br J Ophthalmol       Date:  2008-08-29       Impact factor: 4.638

9.  Changes in corneal wavefront aberrations in microincision and small-incision cataract surgery.

Authors:  NuXia Tong; Ji C He; Fan Lu; QinMei Wang; Jia Qu; Yun-E Zhao
Journal:  J Cataract Refract Surg       Date:  2008-12       Impact factor: 3.351

10.  Comparison of bimanual and micro-coaxial phacoemulsification with torsional ultrasound.

Authors:  Yujuan Wang; Yuanling Xia; Xialin Liu; Danying Zheng; Lixia Luo; Yizhi Liu
Journal:  Acta Ophthalmol       Date:  2010-02-16       Impact factor: 3.761

View more
  8 in total

1.  New thin-film adhesive for sealing full-thickness corneal incisions in rabbits.

Authors:  Jackie Tan; Leslie John Ray Foster; Frank James Lovicu; Stephanie Louise Watson
Journal:  J Cataract Refract Surg       Date:  2022-03-01       Impact factor: 3.528

2.  A comparison of surgical efficacy between a 1.8-mm microincision and 3.2-mm and 5.5-mm incisions for phacoemulsification.

Authors:  E Song; Xin Li; Ming-Chao Bi; Hua Ren; Dan Wang; Zhi-Hua Cui; Wei Yang; Hui Shi; Ya-Bin Sun
Journal:  Int J Ophthalmol       Date:  2018-03-18       Impact factor: 1.779

3.  Induction of oxidative stress in human aqueous and vitreous humors by Nd:YAG laser posterior capsulotomy.

Authors:  Loredana Bergandi; Oleksii A Skorokhod; Federica Franzone; Rosalba La Grotta; Evelin Schwarzer; Raffaele Nuzzi
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

4.  One-year follow-up of changes in refraction and aberrations induced by corneal incision.

Authors:  Eloy A Villegas; Encarna Alcón; Elena Rubio; José María Marín; Pablo Artal
Journal:  PLoS One       Date:  2019-11-18       Impact factor: 3.240

5.  MicroRNA-124 facilitates lens epithelial cell apoptosis by inhibiting SPRY2 and MMP-2.

Authors:  Yan Liu; Shuting Li; Yao Liu; Xujing Lv; Qing Zhou
Journal:  Mol Med Rep       Date:  2021-03-24       Impact factor: 2.952

Review 6.  Risk factors for fluctuations in corneal endothelial cell density (Review).

Authors:  Renata Vaiciuliene; Neda Rylskyte; Gabija Baguzyte; Vytautas Jasinskas
Journal:  Exp Ther Med       Date:  2021-12-10       Impact factor: 2.447

7.  Retrospective Comparison of Intraoperative Parameters, Efficacy and Safety in Cataract Surgery Between Halogen and Light-Emitting Diode (LED) Illuminated Surgical Microscope.

Authors:  Sagol Tangjanyatam
Journal:  Clin Ophthalmol       Date:  2021-09-02

8.  Correlation Between Degree of Lens Opacity and the Phacoemulsification Energy Parameters Using Different Imaging Methods in Age-Related Cataract.

Authors:  Li Feng; Fangkun Zhao; Xin Ke; Jiangyue Zhao; Mingyu Shi
Journal:  Transl Vis Sci Technol       Date:  2022-03-02       Impact factor: 3.283

  8 in total