Literature DB >> 17587526

Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography.

Michael D Shapiro1, Antonio J Pena, John H Nichols, Stewart Worrell, Fabian Bamberg, Nina Dannemann, Suhny Abbara, Ricardo C Cury, Thomas J Brady, Udo Hoffmann.   

Abstract

OBJECTIVE: While beta-blockers are routinely administered to patients prior to coronary computed tomography angiography (CTA), their effectiveness is unknown. We therefore assessed the efficacy of beta-blockade with regards to heart rate (HR) control and image quality in an unselected patient cohort.
METHODS: We studied 150 consecutive patients (104 men/46 female; mean age, 56+/-13 years) referred for coronary CTA. Intravenous metoprolol (5-20mg) was administered to patients with a HR >65 beats per minute (bpm). The goal HR was defined as an average HR <65 bpm without a single measurement above 68 bpm.
RESULTS: Overall, 45% (68/150) of patients met the HR criteria for beta-blocker administration of which 76% (52/68) received metoprolol (mean dose 12+/-10mg). Of the 52 patients who received beta-blocker versus the 98 who did not, 18 (35%) versus 62 (64%) patients achieved the goal HR, respectively. All patients who achieved the target HR had an evaluable CTA while five patients who did not achieve the target HR had at least one non-evaluable coronary artery due to motion artifact. There was also a significant reduction in any motion artifact among those who achieved the goal HR as compared to those who did not (p=0.001). Logistic regression revealed an increase in the odds of stair step artifact of 11.6% (95% CI: 2.4% decrease, 27.5% increase) per 1 bpm increase in the standard deviation of scan HR.
CONCLUSION: Overall, efficacy of beta-blocker administration to reach target HR is limited. Improvements in CT scanner temporal resolution are mandatory to achieve consistently high image quality independent of HR and beta-blocker administration.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17587526     DOI: 10.1016/j.ejrad.2007.05.006

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  16 in total

1.  Absorbed radiation dose in radiosensitive organs during coronary CT angiography using 320-MDCT: effect of maximum tube voltage and heart rate variations.

Authors:  Boris Nikolic; Faisal Khosa; Pei-Jan Paul Lin; Atif N Khan; Sheryar Sarwar; Chun-Shan Yam; Laurence E Court; Vassilios Raptopoulos; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2010-12       Impact factor: 3.959

2.  Right coronary artery-to-right ventricle fistula in a pediatric patient evaluated by 64-detector-row computed tomographic coronary angiography.

Authors:  Aloha Meave; Gabriela Melendez; Juan Manuel Ochoa; Pedro Alberto Lamothe; Rodrigo Calleja; Erick Alexanderson
Journal:  Tex Heart Inst J       Date:  2009

Review 3.  Image quality in coronary CT angiography: challenges and technical solutions.

Authors:  Olivier Ghekiere; Rodrigo Salgado; Nico Buls; Tim Leiner; Isabelle Mancini; Piet Vanhoenacker; Paul Dendale; Alain Nchimi
Journal:  Br J Radiol       Date:  2017-03-07       Impact factor: 3.039

4.  Safety and efficacy of oral ivabradine as a heart rate-reducing agent in patients undergoing CT coronary angiography.

Authors:  K K Adile; A Kapoor; S K Jain; A Gupta; S Kumar; S Tewari; N Garg; P K Goel
Journal:  Br J Radiol       Date:  2012-08       Impact factor: 3.039

Review 5.  Practical instructions for using drugs in CT and MR cardiac imaging.

Authors:  Giuseppe Rovere; Agostino Meduri; Giancarlo Savino; Francesco Ciriaco Flammia; Francesca Lo Piccolo; Maria Rachele Pia Carafa; Anna Rita Larici; Luigi Natale; Biagio Merlino; Riccardo Marano
Journal:  Radiol Med       Date:  2020-08-24       Impact factor: 3.469

6.  Failed heart rate control with oral metoprolol prior to coronary CT angiography: effect of additional intravenous metoprolol on heart rate, image quality and radiation dose.

Authors:  Laura Jiménez-Juan; Elsie T Nguyen; Bernd J Wintersperger; Hadas Moshonov; Andrew M Crean; Djeven P Deva; Narinder S Paul; Felipe S Torres
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-24       Impact factor: 2.357

7.  Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate.

Authors:  Haruhiko Machida; Xiao-Zhu Lin; Rika Fukui; Yun Shen; Shigeru Suzuki; Isao Tanaka; Takuya Ishikawa; Etsuko Tate; Eiko Ueno
Journal:  Jpn J Radiol       Date:  2014-12-12       Impact factor: 2.374

8.  Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering.

Authors:  Lars Husmann; Bernhard A Herzog; Nina Burkhard; Fuminari Tatsugami; Ines Valenta; Oliver Gaemperli; Christophe A Wyss; Ulf Landmesser; Philipp A Kaufmann
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

9.  Impact of heart rate on diagnostic accuracy of second generation 320-detector computed tomography coronary angiography.

Authors:  Nitesh Nerlekar; Brian S Ko; Arthur Nasis; James D Cameron; Michael Leung; Adam J Brown; Dennis T L Wong; Philip J Ngu; John M Troupis; Sujith K Seneviratne
Journal:  Cardiovasc Diagn Ther       Date:  2017-06

10.  Safety and efficacy of a drug regimen to control heart rate during 64-slice ECG-gated coronary CTA in children.

Authors:  Cynthia K Rigsby; R Andrew deFreitas; Angela C Nicholas; Christianne Leidecker; Andrew J Johanek; Peter Anley; Deli Wang; Tetsu Uejima
Journal:  Pediatr Radiol       Date:  2010-05-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.