Literature DB >> 18215814

Fourier correction for spatially variant collimator blurring in SPECT.

W Xia1, R M Lewitt, P R Edholm.   

Abstract

In single-photon emission computed tomography (SPECT), projection data are acquired by rotating the photon detector around a patient, either in a circular orbit or in a noncircular orbit. The projection data of the desired spatial distribution of emission activity is blurred by the point-response function of the collimator that is used to define the range of directions of gamma-ray photons reaching the detector. The point-response function of the collimator is not spatially stationary, but depends on the distance from the collimator to the point. Conventional methods for deblurring collimator projection data are based on approximating the actual distance-dependent point-response function by a spatially invariant blurring function, so that deconvolution methods can be applied independently to the data at each angle of view. A method is described here for distance-dependent preprocessing of SPECT projection data prior to image reconstruction. Based on the special distance-dependent characteristics of the Fourier coefficients of the sinogram, a spatially variant inverse filter can be developed to process the projection data in all views simultaneously. The algorithm is first derived from Fourier analysis of the projection data from the circular orbit geometry. For circular orbit projection data, experimental results from both simulated data and real phantom data indicate the potential of this method. It is shown that the spatial filtering method can be extended to the projection data from the noncircular orbit geometry. Experiments on simulated projection data from an elliptical orbit demonstrate correction of the spatially variant blurring and distortion in the reconstructed image caused by the noncircular orbit geometry.

Entities:  

Year:  1995        PMID: 18215814     DOI: 10.1109/42.370406

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  10 in total

1.  Uniform attenuation correction using the frequency-distance principle.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

2.  Parallelization of Iterative Reconstruction Algorithms in Multiple Modalities.

Authors:  Debasis Mitra; Hui Pan; Fares Alhassen; Youngho Seo
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2014-11

3.  Fully three-dimensional defocus-gradient corrected backprojection in cryoelectron microscopy.

Authors:  Ivan G Kazantsev; Joanna Klukowska; Gabor T Herman; Laslo Cernetic
Journal:  Ultramicroscopy       Date:  2010-04-18       Impact factor: 2.689

4.  Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: a multicenter trial.

Authors:  J M Links; L C Becker; P Rigo; R Taillefer; L Hanelin; F Anstett; D Burckhardt; L Mixon
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

5.  A postprocessing method for compensation of scatter and collimator blurring in SPECT: a proof-of-concept study.

Authors:  Yan Yan; Gengsheng Lawrence Zeng
Journal:  J Nucl Med Technol       Date:  2009-05-15

6.  The geometric response function for convergent slit-slat collimators.

Authors:  Yusheng Li; James Oldendick; Caesar E Ordonez; Wei Chang
Journal:  Phys Med Biol       Date:  2009-02-13       Impact factor: 3.609

7.  Compensating for Non-Stationary Blurring by Further Blurring and Deconvolution.

Authors:  Gengsheng L Zeng
Journal:  Int J Imaging Syst Technol       Date:  2009-09-01       Impact factor: 2.000

8.  An Improved Extrapolation Scheme for Truncated CT Data Using 2D Fourier-Based Helgason-Ludwig Consistency Conditions.

Authors:  Yan Xia; Martin Berger; Sebastian Bauer; Shiyang Hu; Andre Aichert; Andreas Maier
Journal:  Int J Biomed Imaging       Date:  2017-07-20

9.  Scatter and blurring compensation in inhomogeneous media using a postprocessing method.

Authors:  Yan Yan; Gengsheng L Zeng
Journal:  Int J Biomed Imaging       Date:  2009-03-04

10.  Three-dimensional analysis of vascular development in the mouse embryo.

Authors:  Johnathon R Walls; Leigh Coultas; Janet Rossant; R Mark Henkelman
Journal:  PLoS One       Date:  2008-08-06       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.