Literature DB >> 23464305

Estimating the 4D respiratory lung motion by spatiotemporal registration and super-resolution image reconstruction.

Guorong Wu1, Qian Wang, Jun Lian, Dinggang Shen.   

Abstract

PURPOSE: One of the main challenges in lung cancer radiation therapy is how to reduce the treatment margin but accommodate the geometric uncertainty of moving tumor. 4D-CT is able to provide the full range of motion information for the lung and tumor. However, accurate estimation of lung motion with respect to the respiratory phase is difficult due to various challenges in image registration, e.g., motion artifacts and large interslice thickness in 4D-CT. Meanwhile, the temporal coherence across respiration phases is usually not guaranteed in the conventional registration methods which consider each phase image in 4D-CT independently. To address these challenges, the authors present a unified approach to estimate the respiratory lung motion with two iterative steps.
METHODS: First, the authors propose a novel spatiotemporal registration algorithm to align all phase images of 4D-CT (in low-resolution) to a high-resolution group-mean image in the common space. The temporal coherence of registration is maintained by a set of temporal fibers that delineate temporal correspondences across different respiratory phases. Second, a super-resolution technique is utilized to build the high-resolution group-mean image with more anatomical details than any individual phase image, thus largely alleviating the registration uncertainty especially in correspondence detection. In particular, the authors use the concept of sparse representation to keep the group-mean image as sharp as possible.
RESULTS: The performance of our 4D motion estimation method has been extensively evaluated on both the simulated datasets and real lung 4D-CT datasets. In all experiments, our method achieves more accurate and consistent results in lung motion estimation than all other state-of-the-art approaches under comparison.
CONCLUSIONS: The authors have proposed a novel spatiotemporal registration method to estimate the lung motion in 4D-CT. Promising results have been obtained, which indicates the high applicability of our method in clinical lung cancer radiation therapy.

Entities:  

Mesh:

Year:  2013        PMID: 23464305      PMCID: PMC4108704          DOI: 10.1118/1.4790689

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  48 in total

1.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

2.  Nonrigid registration of dynamic medical imaging data using nD + t B-splines and a groupwise optimization approach.

Authors:  C T Metz; S Klein; M Schaap; T van Walsum; W J Niessen
Journal:  Med Image Anal       Date:  2010-10-28       Impact factor: 8.545

3.  Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy.

Authors:  Rohini George; Theodore D Chung; Sastry S Vedam; Viswanathan Ramakrishnan; Radhe Mohan; Elisabeth Weiss; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-07-01       Impact factor: 7.038

4.  Generalizing the nonlocal-means to super-resolution reconstruction.

Authors:  Matan Protter; Michael Elad; Hiroyuki Takeda; Peyman Milanfar
Journal:  IEEE Trans Image Process       Date:  2009-01       Impact factor: 10.856

5.  Diffeomorphic demons: efficient non-parametric image registration.

Authors:  Tom Vercauteren; Xavier Pennec; Aymeric Perchant; Nicholas Ayache
Journal:  Neuroimage       Date:  2008-11-07       Impact factor: 6.556

6.  Iterative sorting for four-dimensional CT images based on internal anatomy motion.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter; Peter A Balter
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

7.  Characterization and identification of spatial artifacts during 4D-CT imaging.

Authors:  Dongfeng Han; John Bayouth; Sudershan Bhatia; Milan Sonka; Xiaodong Wu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

8.  Image inpainting by patch propagation using patch sparsity.

Authors:  Zongben Xu; Jian Sun
Journal:  IEEE Trans Image Process       Date:  2010-02-02       Impact factor: 10.856

9.  Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients.

Authors:  Tokihiro Yamamoto; Ulrich Langner; Billy W Loo; John Shen; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-25       Impact factor: 7.038

10.  Four-dimensional computed tomography-based treatment planning for intensity-modulated radiation therapy and proton therapy for distal esophageal cancer.

Authors:  Xiaodong Zhang; Kuai-le Zhao; Thomas M Guerrero; Sean E McGuire; Brian Yaremko; Ritsuko Komaki; James D Cox; Zhouguang Hui; Yupeng Li; Wayne D Newhauser; Radhe Mohan; Zhongxing Liao
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-01       Impact factor: 7.038

View more
  9 in total

1.  Discrete Heat Kernel Smoothing in Irregular Image Domains.

Authors:  Moo K Chung; Yanli Wang; Guorong Wu
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07

2.  Investigating the minimum scan parameters required to generate free-breathing motion artefact-free fast-helical CT.

Authors:  David H Thomas; Jun Tan; Jack Neylon; Tai Dou; Dylan O'Connell; Michael McNitt-Gray; Percy Lee; James Lamb; Daniel A Low
Journal:  Br J Radiol       Date:  2017-11-21       Impact factor: 3.039

3.  Tensor-based dictionary learning for dynamic tomographic reconstruction.

Authors:  Shengqi Tan; Yanbo Zhang; Ge Wang; Xuanqin Mou; Guohua Cao; Zhifang Wu; Hengyong Yu
Journal:  Phys Med Biol       Date:  2015-03-17       Impact factor: 3.609

4.  Few-shot learning for deformable image registration in 4DCT images.

Authors:  Weicheng Chi; Zhiming Xiang; Fen Guo
Journal:  Br J Radiol       Date:  2021-10-18       Impact factor: 3.039

5.  End-to-End Deep Learning of Non-rigid Groupwise Registration and Reconstruction of Dynamic MRI.

Authors:  Junwei Yang; Thomas Küstner; Peng Hu; Pietro Liò; Haikun Qi
Journal:  Front Cardiovasc Med       Date:  2022-04-28

6.  LROC Investigation of Three Strategies for Reducing the Impact of Respiratory Motion on the Detection of Solitary Pulmonary Nodules in SPECT.

Authors:  Mark S Smyczynski; Howard C Gifford; Joyoni Dey; Andre Lehovich; Joseph E McNamara; W Paul Segars; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2016-02-15       Impact factor: 1.679

7.  Contour propagation using non-uniform cubic B-splines for lung tumor delineation in 4D-CT.

Authors:  Yongchuan Liu; Renchao Jin; Mi Chen; Enmin Song; Xiangyang Xu; Sheng Zhang; Chih-Cheng Hung
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-07-16       Impact factor: 2.924

8.  GroupRegNet: a groupwise one-shot deep learning-based 4D image registration method.

Authors:  Yunlu Zhang; Xue Wu; H Michael Gach; Harold Li; Deshan Yang
Journal:  Phys Med Biol       Date:  2021-02-12       Impact factor: 3.609

9.  Vector-field dynamic x-ray (VF-DXR) using optical flow method in patients with chronic obstructive pulmonary disease.

Authors:  Takuya Hino; Akinori Tsunomori; Akinori Hata; Tomoyuki Hida; Yoshitake Yamada; Masako Ueyama; Tsutomu Yoneyama; Atsuko Kurosaki; Takeshi Kamitani; Kousei Ishigami; Takenori Fukumoto; Shoji Kudoh; Hiroto Hatabu
Journal:  Eur Radiol Exp       Date:  2022-01-31
  9 in total