Literature DB >> 19194766

Biomechanical stability of four fixation constructs for distal radius fractures.

John T Capo1, Tosca Kinchelow, Kenneth Brooks, Virak Tan, Michaele Manigrasso, Kristin Francisco.   

Abstract

Implants available for distal radius fracture fixation include dorsal nonlocked plating (DNLP), volar locked plating (VLP), radial-ulnar dual-column locked plating (DCPs), and locked intramedullary fixation (IMN). This study examines the biomechanical properties of these four different fixation constructs. In 28 fresh-frozen radii, a wedge osteotomy was performed, creating an unstable fracture model and the four fixation constructs employed (DNLP, VLP, DCPs, and IMN). Dorsal bending loads were applied and bending stiffness, load to yield 5 mm displacement, and ultimate failure were measured. Bending stiffness for VLP (16.7 N/mm) was significantly higher than for DNLP (6.8 N/mm), while IMN (12.6 N/mm) and DCPs (11.8 N/mm) were similar. Ultimate load to failure occurred at 278.2 N for the VLP, 245.7 N for the IMN, and 52.0 N for the DNLP. The VLP was significantly stronger than the DNLP and DCPs, and the IMN and DCPs were stronger than the DNLP. The VLP has higher average bending stiffness, ultimate bending strength, and resistance to 5 mm displacement than the other constructs and significantly higher ultimate bending strength than the DCPs and DNLP. There was no statistically significant difference between the VLP and IMN. VLP and IMN fixation of distal radius fractures can achieve comparable stability.

Entities:  

Year:  2009        PMID: 19194766      PMCID: PMC2724612          DOI: 10.1007/s11552-008-9156-5

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  21 in total

1.  Distal radius fracture fixation with an intramedullary nail.

Authors:  Virak Tan; John Capo; Mark Warburton
Journal:  Tech Hand Up Extrem Surg       Date:  2005-12

2.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

3.  A biomechanical comparison between two volar locking plate systems for distal radius fractures.

Authors:  Li Chen; Qiang Dai; Montri D Wongworawat
Journal:  Orthopedics       Date:  2006-10       Impact factor: 1.390

4.  Design and biomechanics of a plate for the distal radius.

Authors:  D Gesensway; M D Putnam; P L Mente; J L Lewis
Journal:  J Hand Surg Am       Date:  1995-11       Impact factor: 2.230

5.  Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation.

Authors:  Thomas W Wright; Marybeth Horodyski; Dean W Smith
Journal:  J Hand Surg Am       Date:  2005-03       Impact factor: 2.230

6.  Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures.

Authors:  D Ring; J B Jupiter; J Brennwald; U Büchler; H Hastings
Journal:  J Hand Surg Am       Date:  1997-09       Impact factor: 2.230

7.  Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study.

Authors:  Corey Trease; Terence McIff; E Bruce Toby
Journal:  J Hand Surg Am       Date:  2005-07       Impact factor: 2.230

8.  Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability.

Authors:  Andrew A Willis; Keiji Kutsumi; Mark E Zobitz; William P Cooney
Journal:  J Bone Joint Surg Am       Date:  2006-11       Impact factor: 5.284

9.  Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment.

Authors:  Paul M Simic; Jason Robison; Michael J Gardner; Richard H Gelberman; Andrew J Weiland; Martin I Boyer
Journal:  J Hand Surg Am       Date:  2006-03       Impact factor: 2.230

10.  Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study.

Authors:  Denju Osada; Steven F Viegas; Munir A Shah; Randal P Morris; Rita M Patterson
Journal:  J Hand Surg Am       Date:  2003-01       Impact factor: 2.230

View more
  4 in total

1.  The role of locking technology in the upper extremity.

Authors:  Siddharth B Joglekar; Asif M Ilyas
Journal:  J Hand Microsurg       Date:  2010-01-08

2.  Volar, Intramedullary, and Percutaneous Fixation of Distal Radius Fractures.

Authors:  Ram Alluri; Matthew Longacre; William Pannell; Milan Stevanovic; Alidad Ghiassi
Journal:  J Wrist Surg       Date:  2015-11

3.  Age-Related Variations in Volar Cortical Angle of the Distal Radius.

Authors:  Rikesh A Gandhi; Patrick J Hesketh; Evan R Bannister; Ronnie Sebro; Samir Mehta
Journal:  Hand (N Y)       Date:  2018-12-31

4.  Volar Locking Plate Versus Dorsal Locking Nail-Plate Fixation for Dorsally Displaced Unstable Extra-Articular Distal Radial Fractures: Functional and Radiographic Results from a Randomized Controlled Trial.

Authors:  Morten Eikrem; Hege Brannsten; Dagfinn Bjørkøy; Tom Lian; Jan Erik Madsen; Wender Figved
Journal:  JB JS Open Access       Date:  2021-10-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.