Literature DB >> 16516731

Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment.

Paul M Simic1, Jason Robison, Michael J Gardner, Richard H Gelberman, Andrew J Weiland, Martin I Boyer.   

Abstract

PURPOSE: To evaluate objective functional and radiographic outcomes after internal fixation of acute, displaced, and unstable fractures of the distal aspect of the radius in adults by using a low-profile dorsal plating system. Our hypothesis was that the low-profile dorsal plating system would allow for a reduction of extensor tendon irritation and pain and provide stable osseous fixation.
METHODS: Sixty consecutive unstable fractures in 59 patients were treated by open reduction internal fixation using a low-profile dorsal plating system. There were 29 type A, 14 type B, and 8 type C fractures (AO classification system). Fifty patients with 51 fractures returned for outcomes assessment by physical examination, plain radiographs, and completion of a validated musculoskeletal function assessment questionnaire. The minimum follow-up period was 1 year; the mean follow-up period was 24 months. Clinical evaluation was performed and plain radiographs were assessed for maintenance of immediate postoperative reduction and implant position. Objective functional assessment was obtained through the Disabilities of the Arm, Shoulder, and Hand questionnaire.
RESULTS: Outcomes analysis showed no cases of extensor tendon irritation or rupture. Hardware removal was performed in 1 patient but no extensor tendon irritation or rupture was evidenced. The mean Disabilities of the Arm, Shoulder, and Hand score was 11.9; implant-related discomfort was minimal. All patients had an excellent (31 patients) or good (19 patients) result according to the scoring system of Gartland and Werley. The mean active range of motion was greater than 80% of that of the contralateral wrist in flexion/extension, pronation/supination, and ulnar/radial deviation. Extensor tendon function was unimpaired in all patients. Grip and pinch strength averaged 90% and 94% of the contralateral sides, respectively. Radiographic evaluation showed no change in fracture reduction or implant position.
CONCLUSIONS: The treatment of distal radius fractures with a low-profile stainless steel dorsal plating system is a safe and effective method that provides stable internal fixation and allows for full extensor tendon glide and full metacarpophalangeal joint motion. Objective outcome testing showed uniformly good to excellent recovery of wrist and hand function in all patients. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic, Level IV.

Entities:  

Mesh:

Year:  2006        PMID: 16516731     DOI: 10.1016/j.jhsa.2005.10.016

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  23 in total

1.  Outcomes following operative treatment of open fractures of the distal radius: a case control study.

Authors:  Brendan J MacKay; Nicole Montero; Nader Paksima; Kenneth A Egol
Journal:  Iowa Orthop J       Date:  2013

Review 2.  Management of complications of distal radius fractures.

Authors:  Alexandra L Mathews; Kevin C Chung
Journal:  Hand Clin       Date:  2015-02-28       Impact factor: 1.907

3.  Transseptal dorsal approaches to the wrist.

Authors:  Ahmed Zemirline; Gérard Hoël; Kiyohito Naïto; Arnaud Uguen; Philippe Liverneaux; Dominique Le Nen
Journal:  Surg Radiol Anat       Date:  2012-09-01       Impact factor: 1.246

4.  Corrective osteotomies of the radius: Grafting or not?

Authors:  Raffaele Mugnai; Luigi Tarallo; Enrico Lancellotti; Francesco Zambianchi; Ettore Di Giovine; Fabio Catani; Roberto Adani
Journal:  World J Orthop       Date:  2016-02-18

5.  Dorsal Lunate Facet Fracture Reduction Using a Bone Reduction Forceps.

Authors:  Jonathan Lans; Josefina Alvarez; Amir R Kachooei; Sezai Ozkan; Jesse B Jupiter
Journal:  J Wrist Surg       Date:  2018-10-03

6.  Management distal radius and distal ulnar fractures with fragment specific plate.

Authors:  William B Geissler
Journal:  J Wrist Surg       Date:  2013-05

7.  Corrective osteotomy for deformity of the distal radius using a volar locking plate.

Authors:  Brett Peterson; Varun Gajendran; Robert M Szabo
Journal:  Hand (N Y)       Date:  2007-08-10

8.  "Sandwich" plating for intra-articular distal radius fractures with volar and dorsal metaphyseal comminution.

Authors:  Charles S Day; Atul F Kamath; Eric Makhni; Jerome Jean-Gilles; David Zurakowski
Journal:  Hand (N Y)       Date:  2007-07-13

9.  Biomechanical comparison of different volar fracture fixation plates for distal radius fractures.

Authors:  Kareem Sobky; Todd Baldini; Kenneth Thomas; Joel Bach; Allison Williams; Jennifer Moriatis Wolf
Journal:  Hand (N Y)       Date:  2007-09-07

10.  Comparison of locked volar plating versus pinning and external fixation in the treatment of unstable intraarticular distal radius fractures.

Authors:  Marco Rizzo; Brian A Katt; Joshua T Carothers
Journal:  Hand (N Y)       Date:  2007-10-17
View more