Literature DB >> 15781351

Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation.

Thomas W Wright1, Marybeth Horodyski, Dean W Smith.   

Abstract

PURPOSE: The purpose of this study was to compare the outcomes of 2 treatments for unstable distal radius fractures: open reduction internal fixation (ORIF) through a volar approach with a fixed-angle implant and a standard external fixation (EF) method.
METHODS: This study included patients with comminuted unstable intra-articular and extra-articular distal radius fractures treated by a single surgeon. Data were gathered retrospectively on 11 patients treated with EF who had been followed up for an average of 47 months (range, 12-84 mo). Prospective data were gathered on 21 patients who were treated with ORIF through a volar approach with a fixed-angle implant. Follow-up evaluation for this group averaged 17 months (range, 12-24 mo). The 2 groups were compared for range of motion (ROM), strength, and functional outcome as measured by the Patient Rated Wrist Evaluation (PRWE) and the Disability of the Arm, Shoulder, and Hand Questionnaire (DASH). Fracture reduction was evaluated from radiographs taken at the last follow-up visit and compared between groups.
RESULTS: The mean passive wrist ROM at the final follow-up evaluation in EF patients was 59 degrees extension and 57 degrees flexion, compared with 63 degrees extension and 64 degrees flexion in patients treated with ORIF. Passive pronation/supination arc of motion was similar for the 2 groups, as were the DASH and PRWE scores. Grip strength as a percentage of the opposite wrist was significantly greater in the external fixation group, a possible consequence of longer follow-up evaluation. Final radiographic measurements for the EF group averaged 5 degrees volar tilt and 25 degrees radial inclination, with 2.2-mm ulnar-positive variance. The ORIF with volar plating group averaged 10 degrees volar tilt and 22 degrees radial inclination, with .5-mm ulnar-negative variance. Radial length and volar tilt were significantly greater for the ORIF group. The average final intra-articular step-off was significantly different, with 1.4-mm step-off in the EF group and .4 mm in the ORIF group.
CONCLUSIONS: The use of ORIF with a volar fixed-angle implant resulted in stable fixation of the distal articular fragments, allowing early postsurgical wrist motion. The PRWE and DASH scores for the groups were equivalent, whereas intra-articular step-off, volar tilt, and radial length were better in the ORIF group. There were few complications, implant removal was not necessary, and early postsurgical wrist ROM was initiated without loss of reduction.

Entities:  

Mesh:

Year:  2005        PMID: 15781351     DOI: 10.1016/j.jhsa.2004.11.014

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  52 in total

1.  The cadaveric anatomy of the distal radius: implications for the use of volar plates.

Authors:  P A McCann; D Clarke; R Amirfeyz; R Bhatia
Journal:  Ann R Coll Surg Engl       Date:  2012-03       Impact factor: 1.891

2.  Outcomes following operative treatment of open fractures of the distal radius: a case control study.

Authors:  Brendan J MacKay; Nicole Montero; Nader Paksima; Kenneth A Egol
Journal:  Iowa Orthop J       Date:  2013

3.  Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly.

Authors:  N Schmelzer-Schmied; P Wieloch; A K Martini; W Daecke
Journal:  Int Orthop       Date:  2008-01-12       Impact factor: 3.075

4.  Preexisting Carpal and Carpometacarpal Osteoarthritis Has No Impact on Function after Distal Radius Fractures.

Authors:  Jonah Hébert Davies; Hugo Centomo; Stéphane Leduc; Pierre Beaumont; G-Yves Laflamme; Dominique M Rouleau
Journal:  J Wrist Surg       Date:  2017-05-02

5.  Retrospective comparison of percutaneous fixation and volar internal fixation of distal radius fractures.

Authors:  Santiago A Lozano-Calderón; Job N Doornberg; David Ring
Journal:  Hand (N Y)       Date:  2007-09-18

6.  External fixation versus open reduction with locked volar plating for geriatric distal radius fractures.

Authors:  Daniel J Lee; John C Elfar
Journal:  Geriatr Orthop Surg Rehabil       Date:  2014-09

7.  Volar plate fixation of intra-articular distal radius fractures: a retrospective study.

Authors:  Margaret W M Fok; Melissa A Klausmeyer; Diego L Fernandez; Jorge L Orbay; Alex Lluch Bergada
Journal:  J Wrist Surg       Date:  2013-08

8.  Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique.

Authors:  Matthias Jacobi; Peter Wahl; Georges Kohut
Journal:  J Orthop Surg Res       Date:  2010-08-11       Impact factor: 2.359

9.  Is there a Consensus in the Management of Distal Radial Fractures?

Authors:  M A Nazar; R Mansingh; R S Bassi; M Waseem
Journal:  Open Orthop J       Date:  2009-11-05

10.  Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures: a randomized study of 50 patients.

Authors:  Antonio Abramo; Philippe Kopylov; Mats Geijer; Magnus Tägil
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.