Literature DB >> 19169835

Specificity improvement for network distributed physiologic alarms based on a simple deterministic reactive intelligent agent in the critical care environment.

James M Blum1, Grant H Kruger, Kathryn L Sanders, Jorge Gutierrez, Andrew L Rosenberg.   

Abstract

Automated physiologic alarms are available in most commercial physiologic monitors. However, due to the variability of data coming from the physiologic sensors describing the state of patients, false positive alarms frequently occur. Each alarm requires review and documentation, which consumes clinicians' time, may reduce patient safety through 'alert fatigue' and makes automated physician paging infeasible. To address these issues a computerized architecture based on simple reactive intelligent agent technology has been developed and implemented in a live critical care unit to facilitate the investigation of deterministic algorithms for the improvement of the sensitivity and specificity of physiologic alarms. The initial proposed algorithm uses a combination of median filters and production rules to make decisions about what alarms to generate. The alarms are used to classify the state of patients and alerts can be easily viewed and distributed using standard network, SQL database and Internet technologies. To evaluate the proposed algorithm, a 28 day study was conducted in the University of Michigan Medical Center's 14 bed Cardiothoracic Intensive Care Unit. Alarms generated by patient monitors, the intelligent agent and alerts documented on patient flow sheets were compared. Significant improvements in the specificity of the physiologic alarms based on systolic and mean blood pressure was found on average to be 99% and 88% respectively. Even through significant improvements were noted based on this algorithm much work still needs to be done to ensure the sensitivity of alarms and methods to handle spurious sensor data due to patient or sensor movement and other influences.

Entities:  

Mesh:

Year:  2009        PMID: 19169835     DOI: 10.1007/s10877-008-9159-3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  13 in total

1.  Making ICU alarms meaningful: a comparison of traditional vs. trend-based algorithms.

Authors:  R Schoenberg; D Z Sands; C Safran
Journal:  Proc AMIA Symp       Date:  1999

2.  Wireless clinical alerts for physiologic, laboratory and medication data.

Authors:  M M Shabot; M LoBue; J Chen
Journal:  Proc AMIA Symp       Date:  2000

3.  Design and implementation of a real-time clinical alerting system for intensive care unit.

Authors:  Hsiao-Ting Chen; Wun-Chun Ma; Der Ming Liou
Journal:  Proc AMIA Symp       Date:  2002

4.  Alarm algorithms in critical care monitoring.

Authors:  Michael Imhoff; Silvia Kuhls
Journal:  Anesth Analg       Date:  2006-05       Impact factor: 5.108

5.  Impact of a computerized clinical decision support system on reducing inappropriate antimicrobial use: a randomized controlled trial.

Authors:  Jessina C McGregor; Elizabeth Weekes; Graeme N Forrest; Harold C Standiford; Eli N Perencevich; Jon P Furuno; Anthony D Harris
Journal:  J Am Med Inform Assoc       Date:  2006-04-18       Impact factor: 4.497

6.  Survey of alarms in an intensive therapy unit.

Authors:  T M O'Carroll
Journal:  Anaesthesia       Date:  1986-07       Impact factor: 6.955

7.  Unit-wide notification of ventilator disconnections.

Authors:  R Scott Evans; Kyle V Johnson; Vrena B Flint; A Tupper Kinder; William L Hawley; Charles R Lyon; David K Vawdrey; George E Thomsen
Journal:  AMIA Annu Symp Proc       Date:  2005

8.  Intelligent systems in patient monitoring and therapy management. A survey of research projects.

Authors:  S Uckun
Journal:  Int J Clin Monit Comput       Date:  1994-11

9.  Electronic alerts to prevent venous thromboembolism among hospitalized patients.

Authors:  Nils Kucher; Sophia Koo; Rene Quiroz; Joshua M Cooper; Marilyn D Paterno; Boris Soukonnikov; Samuel Z Goldhaber
Journal:  N Engl J Med       Date:  2005-03-10       Impact factor: 91.245

10.  Crying wolf: false alarms in a pediatric intensive care unit.

Authors:  S T Lawless
Journal:  Crit Care Med       Date:  1994-06       Impact factor: 7.598

View more
  3 in total

1.  Sensor fusion methods for reducing false alarms in heart rate monitoring.

Authors:  Gabriel Borges; Valner Brusamarello
Journal:  J Clin Monit Comput       Date:  2015-10-06       Impact factor: 2.502

2.  Influence of non-invasive blood pressure measurement intervals on the occurrence of intra-operative hypotension.

Authors:  Grant H Kruger; Amy Shanks; Sachin Kheterpal; Tyler Tremper; Chi-Jung Chiang; Robert E Freundlich; James M Blum; Albert J Shih; Kevin K Tremper
Journal:  J Clin Monit Comput       Date:  2017-09-30       Impact factor: 2.502

3.  The iOSC3 system: using ontologies and SWRL rules for intelligent supervision and care of patients with acute cardiac disorders.

Authors:  Marcos Martínez-Romero; José M Vázquez-Naya; Javier Pereira; Miguel Pereira; Alejandro Pazos; Gerardo Baños
Journal:  Comput Math Methods Med       Date:  2013-02-16       Impact factor: 2.238

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.