Literature DB >> 28965158

Influence of non-invasive blood pressure measurement intervals on the occurrence of intra-operative hypotension.

Grant H Kruger1,2, Amy Shanks3, Sachin Kheterpal3, Tyler Tremper3, Chi-Jung Chiang4, Robert E Freundlich5, James M Blum6, Albert J Shih7,8, Kevin K Tremper3.   

Abstract

The American Society of Anesthesiologists Standards for Basic Monitoring recommends blood pressure (BP) measurement every 5 min. Research has shown distractions or technical factors can cause prolonged measurement intervals exceeding 5 min. We investigated the relationship between prolonged non-invasive BP (NIBP) measurement interval and the incidence of hypotension, detected post-interval. Our secondary outcome was to determine independent predictors of these prolonged NIBP measurement intervals. Retrospective data were analyzed from 139,509 general anesthesia cases from our institution's Anesthesia Information Management System (AIMS). Absolute hypotension (AH) was defined a priori as a systolic BP < 80 mmHg and relative hypotension (RH) was defined as a 40% decrease in systolic BP from the preoperative baseline. Odds ratios (OR) with 95% confidence intervals and Pearson's Chi square Test reported the association of prolonged NIBP measurement intervals on hypotension detected post-NIBP measurement interval. Logistic regression models were developed to determine independent predictors of NIBP measurement intervals. The analysis revealed that NIBP measurement intervals greater than 6 and 10 min are associated with an approximately four times higher incidence of a patient transitioning into hypotension (AH/RH > 6 min OR 4.0 / 3.6; AH/RH > 10 min OR 4.3 / 3.9; p < 0.001). A key finding was that the "> 10-minute AH model" indicated that age 41-80, increased co-morbidity profile, obesity and turning (repositioning) of the operative room table were significant predictors of prolonged NIBP measurement intervals (p < 0.001). While we do not suggest NIBP measurement intervals cause hypotension, intervals greater than 6 and 10 min are associated with a fourfold increase in the propensity of an undetected transition into both RH or AH. These data support current monitoring guidelines.

Entities:  

Keywords:  Intra-operative hypertension; Measurement gaps; Non-invasive blood pressure; Physiologic monitoring

Mesh:

Year:  2017        PMID: 28965158      PMCID: PMC6138874          DOI: 10.1007/s10877-017-0065-4

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  14 in total

1.  Anesthesia alarms in context: an observational study.

Authors:  F J Seagull; P M Sanderson
Journal:  Hum Factors       Date:  2001       Impact factor: 2.888

2.  Preoperative and intraoperative predictors of cardiac adverse events after general, vascular, and urological surgery.

Authors:  Sachin Kheterpal; Michael O'Reilly; Michael J Englesbe; Andrew L Rosenberg; Amy M Shanks; Lingling Zhang; Edward D Rothman; Darrell A Campbell; Kevin K Tremper
Journal:  Anesthesiology       Date:  2009-01       Impact factor: 7.892

3.  Intraoperative hypotension and 1-year mortality after noncardiac surgery.

Authors:  Jilles B Bijker; Wilton A van Klei; Yvonne Vergouwe; Douglas J Eleveld; Leo van Wolfswinkel; Karel G M Moons; Cor J Kalkman
Journal:  Anesthesiology       Date:  2009-12       Impact factor: 7.892

4.  Near real-time notification of gaps in cuff blood pressure recordings for improved patient monitoring.

Authors:  Bala G Nair; Mayumi Horibe; Shu-Fang Newman; Wei-Ying Wu; Howard A Schwid
Journal:  J Clin Monit Comput       Date:  2013-01-03       Impact factor: 2.502

5.  Obesity: preventing and managing the global epidemic. Report of a WHO consultation.

Authors: 
Journal:  World Health Organ Tech Rep Ser       Date:  2000

6.  The wolf is crying in the operating room: patient monitor and anesthesia workstation alarming patterns during cardiac surgery.

Authors:  Felix Schmid; Matthias S Goepfert; Daniela Kuhnt; Volker Eichhorn; Stefan Diedrichs; Hermann Reichenspurner; Alwin E Goetz; Daniel A Reuter
Journal:  Anesth Analg       Date:  2010-10-21       Impact factor: 5.108

7.  Impact of intraoperative hypotension on hospital stay in major abdominal surgery.

Authors:  Vassilios Tassoudis; George Vretzakis; Argyro Petsiti; Georgia Stamatiou; Katerina Bouzia; Michael Melekos; George Tzovaras
Journal:  J Anesth       Date:  2011-05-06       Impact factor: 2.078

8.  Auditory alarms during anesthesia monitoring with an integrated monitoring system.

Authors:  F E Block; C Schaaf
Journal:  Int J Clin Monit Comput       Date:  1996-05

9.  The deleterious effects of intraoperative hypotension on outcome in patients with severe head injuries.

Authors:  J A Pietropaoli; F B Rogers; S R Shackford; S L Wald; J D Schmoker; J Zhuang
Journal:  J Trauma       Date:  1992-09

10.  Specificity improvement for network distributed physiologic alarms based on a simple deterministic reactive intelligent agent in the critical care environment.

Authors:  James M Blum; Grant H Kruger; Kathryn L Sanders; Jorge Gutierrez; Andrew L Rosenberg
Journal:  J Clin Monit Comput       Date:  2009-01-24       Impact factor: 2.502

View more
  2 in total

Review 1.  Journal of clinical monitoring and computing end of year summary 2018: hemodynamic monitoring and management.

Authors:  Bernd Saugel; Moritz Flick; Karim Bendjelid; Lester A H Critchley; Simon T Vistisen; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2019-03-07       Impact factor: 2.502

Review 2.  Intraoperative Monitoring of the Obese Patient Undergoing Surgery: A Narrative Review.

Authors:  Andrea P Haren; Shrijit Nair; Maria C Pace; Pasquale Sansone
Journal:  Adv Ther       Date:  2021-06-05       Impact factor: 3.845

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.