Literature DB >> 10566385

Making ICU alarms meaningful: a comparison of traditional vs. trend-based algorithms.

R Schoenberg1, D Z Sands, C Safran.   

Abstract

Much of the work in the ICU revolves around information that is recorded by electronic devices. Such devices typically incorporate simple alarm functions that trigger when a value exceeds predefined limits. Depending on the parameter followed, these "boundary based" alarms tend to produce vast numbers of false alarms. Some are the result of false reading and some the result of true but clinically insignificant readings. We present a computerized module that analyzes real-time data from multiple monitoring devices using a customizable logic engine. The module was tested on 6 intensive care unit patients over 5 days, running alarm algorithms for heart rate, systolic and diastolic blood pressure as well as arterial oxygen saturation. Results show a ten-fold increase in positive predictive value of alarms from 3% using monitor alarms to 32% using the module. The module's overall sensitivity was 82%, failing to detect 18% of significant alarms as defined by the ICU staff. The results suggests that implementation of such methodology may assist in filtering false and insignificant alarms in the ICU setting.

Entities:  

Mesh:

Year:  1999        PMID: 10566385      PMCID: PMC2232567     

Source DB:  PubMed          Journal:  Proc AMIA Symp        ISSN: 1531-605X


  14 in total

1.  Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room.

Authors:  C Dumas; J A Wahr; K K Tremper
Journal:  Anesth Analg       Date:  1996-08       Impact factor: 5.108

2.  A study of the incorrect use of ventilator disconnection alarms.

Authors:  R M Campbell; A Sheikh; M M Crosse
Journal:  Anaesthesia       Date:  1996-04       Impact factor: 6.955

3.  Poor prognosis for existing monitors in the intensive care unit.

Authors:  C L Tsien; J C Fackler
Journal:  Crit Care Med       Date:  1997-04       Impact factor: 7.598

4.  Human probability matching behaviour in response to alarms of varying reliability.

Authors:  J P Bliss; R D Gilson; J E Deaton
Journal:  Ergonomics       Date:  1995-11       Impact factor: 2.778

Review 5.  Computers in critical care.

Authors:  T D East; C J Wallace; A H Morris; R M Gardner; D R Westenskow
Journal:  Crit Care Nurs Clin North Am       Date:  1995-06       Impact factor: 1.326

Review 6.  Symbiosis of nurse and machine through fuzzy logic: improved specificity of a neonatal pulse oximeter alarm.

Authors:  E M Bosque
Journal:  ANS Adv Nurs Sci       Date:  1995-12       Impact factor: 1.824

7.  Are there too many alarms in the intensive care unit? An overview of the problems.

Authors:  C Meredith; J Edworthy
Journal:  J Adv Nurs       Date:  1995-01       Impact factor: 3.187

Review 8.  Patient data management systems in anaesthesia: an emerging technology.

Authors:  Y G Weiss; S Cotev; B Drenger; R Katzenelson
Journal:  Can J Anaesth       Date:  1995-10       Impact factor: 5.063

9.  Pulse oximetry in ventilated preterm newborns: reliability of detection of hyperoxaemia and hypoxaemia, and feasibility of alarm settings.

Authors:  F Paky; C M Koeck
Journal:  Acta Paediatr       Date:  1995-06       Impact factor: 2.299

10.  A CQI approach to the investigation of noise levels within the intensive care unit environment.

Authors:  C Stephens; K Daffurn; S Middleton
Journal:  Aust Crit Care       Date:  1995-03       Impact factor: 2.737

View more
  9 in total

1.  Design and implementation of a real-time clinical alerting system for intensive care unit.

Authors:  Hsiao-Ting Chen; Wun-Chun Ma; Der Ming Liou
Journal:  Proc AMIA Symp       Date:  2002

2.  Validation of an electronic surveillance system for acute lung injury.

Authors:  Vitaly Herasevich; Murat Yilmaz; Hasrat Khan; Rolf D Hubmayr; Ognjen Gajic
Journal:  Intensive Care Med       Date:  2009-03-12       Impact factor: 17.440

3.  Predictive Monitoring of Critical Cardiorespiratory Alarms in Neonates Under Intensive Care.

Authors:  Rohan Joshi; Zheng Peng; Xi Long; Loe Feijs; Peter Andriessen; Carola Van Pul
Journal:  IEEE J Transl Eng Health Med       Date:  2019-11-22       Impact factor: 3.316

4.  Informatics infrastructure for syndrome surveillance, decision support, reporting, and modeling of critical illness.

Authors:  Vitaly Herasevich; Brian W Pickering; Yue Dong; Steve G Peters; Ognjen Gajic
Journal:  Mayo Clin Proc       Date:  2010-03       Impact factor: 7.616

Review 5.  Connecting the dots: rule-based decision support systems in the modern EMR era.

Authors:  Vitaly Herasevich; Daryl J Kor; Arun Subramanian; Brian W Pickering
Journal:  J Clin Monit Comput       Date:  2013-02-28       Impact factor: 2.502

Review 6.  Medical audible alarms: a review.

Authors:  Judy Edworthy
Journal:  J Am Med Inform Assoc       Date:  2012-10-25       Impact factor: 4.497

7.  Specificity improvement for network distributed physiologic alarms based on a simple deterministic reactive intelligent agent in the critical care environment.

Authors:  James M Blum; Grant H Kruger; Kathryn L Sanders; Jorge Gutierrez; Andrew L Rosenberg
Journal:  J Clin Monit Comput       Date:  2009-01-24       Impact factor: 2.502

Review 8.  Alarms in the intensive care unit: how can the number of false alarms be reduced?

Authors:  M C Chambrin
Journal:  Crit Care       Date:  2001-05-23       Impact factor: 9.097

9.  Addressing vital sign alarm fatigue using personalized alarm thresholds.

Authors:  Sarah Poole; Nigam Shah
Journal:  Pac Symp Biocomput       Date:  2018
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.