Literature DB >> 19165881

Simultaneous z-shim method for reducing susceptibility artifacts with multiple transmitters.

Weiran Deng1, Cungeng Yang, Vijayanand Alagappan, Lawrence L Wald, Fernando E Boada, V Andrew Stenger.   

Abstract

The signal loss susceptibility artifact is a major limitation in gradient-echo MRI applications. Various methods, including z-shim techniques and multidimensional tailored radio frequency (RF) pulses, have been proposed to mitigate the through-plane signal loss artifact, which is dominant in axial slices above the sinus region. Unfortunately, z-shim techniques require multiple steps and multidimensional RF methods are complex, with long pulse lengths. Parallel transmission methods were recently shown to be promising for improving B1 inhomogeneity and reducing the specific absorption rate. In this work, a novel method using time-shifted slice-select RF pulses is presented for reducing the through-plane signal loss artifact in parallel transmission applications. A simultaneous z-shim is obtained by concurrently applying unique time-shifted pulses on each transmitter. The method is shown to reduce the signal loss susceptibility artifact in gradient-echo images using a four-channel parallel transmission system at 3T. Copyright 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19165881      PMCID: PMC2714643          DOI: 10.1002/mrm.21870

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Reducing inhomogeneity artifacts in functional MRI of human brain activation-thin sections vs gradient compensation.

Authors:  K D Merboldt; J Finsterbusch; J Frahm
Journal:  J Magn Reson       Date:  2000-08       Impact factor: 2.229

2.  Single-shot EPI with signal recovery from the susceptibility-induced losses.

Authors:  A W Song
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

3.  Simultaneous acquisition of gradient-echo and asymmetric spin-echo for single-shot z-shim: Z-SAGA.

Authors:  Keith Arron Heberlein; Xiaoping Hu
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

4.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

5.  Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortex.

Authors:  James L Wilson; Peter Jezzard
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

6.  Parallel excitation with an array of transmit coils.

Authors:  Yudong Zhu
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

7.  Single-shot dual-z-shimmed sensitivity-encoded spiral-in/out imaging for functional MRI with reduced susceptibility artifacts.

Authors:  Trong-Kha Truong; Allen W Song
Journal:  Magn Reson Med       Date:  2008-01       Impact factor: 4.668

8.  Reduction of susceptibility artifact in gradient-echo imaging.

Authors:  Z H Cho; Y M Ro
Journal:  Magn Reson Med       Date:  1992-01       Impact factor: 4.668

9.  Functional mapping of the human visual cortex by magnetic resonance imaging.

Authors:  J W Belliveau; D N Kennedy; R C McKinstry; B R Buchbinder; R M Weisskoff; M S Cohen; J M Vevea; T J Brady; B R Rosen
Journal:  Science       Date:  1991-11-01       Impact factor: 47.728

10.  Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model.

Authors:  S Ogawa; R S Menon; D W Tank; S G Kim; H Merkle; J M Ellermann; K Ugurbil
Journal:  Biophys J       Date:  1993-03       Impact factor: 4.033

View more
  15 in total

1.  Variable slice thickness (VAST) EPI for the reduction of susceptibility artifacts in whole-brain GE-EPI at 7 Tesla.

Authors:  Sascha Brunheim; Sören Johst; Viktor Pfaffenrot; Stefan Maderwald; Harald H Quick; Benedikt A Poser
Journal:  MAGMA       Date:  2017-07-10       Impact factor: 2.310

Review 2.  The future of acquisition speed, coverage, sensitivity, and resolution.

Authors:  Lawrence L Wald
Journal:  Neuroimage       Date:  2012-03-06       Impact factor: 6.556

Review 3.  The neurobiological basis of seeing words.

Authors:  Brian A Wandell
Journal:  Ann N Y Acad Sci       Date:  2011-04       Impact factor: 5.691

4.  Parallel excitation for B-field insensitive fat-saturation preparation.

Authors:  Jeremiah A Heilman; Jamal D Derakhshan; Matthew J Riffe; Natalia Gudino; Jean Tkach; Chris A Flask; Jeffrey L Duerk; Mark A Griswold
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

5.  Simultaneous multislice spectral-spatial excitations for reduced signal loss susceptibility artifact in BOLD functional MRI.

Authors:  Robert J Anderson; Benedikt A Poser; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

6.  Four-dimensional spectral-spatial RF pulses for simultaneous correction of B1+ inhomogeneity and susceptibility artifacts in T2*-weighted MRI.

Authors:  Cungeng Yang; Weiran Deng; Vijayanand Alagappan; Lawrence L Wald; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

7.  Simple analytical dual-band spectral-spatial RF pulses for B(1) + and susceptibility artifact reduction in gradient echo MRI.

Authors:  Cungeng Yang; Weiran Deng; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

8.  Fast joint design method for parallel excitation radiofrequency pulse and gradient waveforms considering off-resonance.

Authors:  Daehyun Yoon; Jeffrey A Fessler; Anna C Gilbert; Douglas C Noll
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

9.  Automated slice-specific simultaneous z-shim method for reducing B1 inhomogeneity and susceptibility-induced signal loss with parallel transmission at 3T.

Authors:  Rainer Schneider; Fernando Boada; Jens Haueisen; Josef Pfeuffer
Journal:  Magn Reson Med       Date:  2014-10-07       Impact factor: 4.668

10.  Simultaneous multislice excitation by parallel transmission.

Authors:  Benedikt A Poser; Robert James Anderson; Bastien Guérin; Kawin Setsompop; Weiran Deng; Azma Mareyam; Peter Serano; Lawrence L Wald; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2013-05-28       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.