Literature DB >> 1734179

Reduction of susceptibility artifact in gradient-echo imaging.

Z H Cho1, Y M Ro.   

Abstract

A new technique with which susceptibility artifact in gradient-echo imaging can be reduced substantially by use of a tailored RF pulse is described. The proposed technique can ideally be applied to the case where high local magnetic field inhomogeneity is dominated by the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method is also proposed. The description of the tailored RF pulse and its proposed application are given and experimental results obtained using a human volunteer with a 2.0-T KAIS NMR system are presented.

Entities:  

Mesh:

Year:  1992        PMID: 1734179     DOI: 10.1002/mrm.1910230120

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  35 in total

1.  Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.

Authors:  V A Stenger; F E Boada; D C Noll
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging.

Authors:  Hsiu-Mei Wu; David M Yousem; Hsiao-Wen Chung; Wan-Yuo Guo; Cheng-Yen Chang; Cheng-Yu Chen
Journal:  AJNR Am J Neuroradiol       Date:  2002-03       Impact factor: 3.825

3.  R*(2) mapping in the presence of macroscopic B₀ field variations.

Authors:  Diego Hernando; Karl K Vigen; Ann Shimakawa; Scott B Reeder
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

4.  Multishot 3D slice-select tailored RF pulses for MRI.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

5.  Enhancing accuracy of magnetic resonance image fusion by defining a volume of interest.

Authors:  B M Hoelper; F Soldner; R Lachner; R Behr
Journal:  Neuroradiology       Date:  2003-09-02       Impact factor: 2.804

6.  Variable-density spiral 3D tailored RF pulses.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

Review 7.  Spiral imaging in fMRI.

Authors:  Gary H Glover
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

8.  T1rho contrast in functional magnetic resonance imaging.

Authors:  Justin Hulvershorn; Arijitt Borthakur; Luke Bloy; Eugene E Gualtieri; Ravinder Reddy; John S Leigh; Mark A Elliott
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

9.  Excitation UNFOLD (XUNFOLD) to improve the temporal resolution of multishot tailored RF pulses.

Authors:  V Andrew Stenger; Marius S Giurgi; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

10.  Interleaved spiral-in/out with application to functional MRI (fMRI).

Authors:  Christine S Law; Gary H Glover
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.