Literature DB >> 19130122

Dual-energy CT angiography in peripheral arterial occlusive disease.

Carolin Brockmann1, Susanne Jochum, Maliha Sadick, Kurt Huck, Peter Ziegler, Christian Fink, Stefan O Schoenberg, Steffen J Diehl.   

Abstract

We sought to study the accuracy of dual-energy computed tomographic angiography (DE-CTA) for the assessment of symptomatic peripheral arterial occlusive disease of the lower extremity by using the dual-energy bone removal technique compared with a commercially available conventional bone removal tool. Twenty patients underwent selective digital subtraction angiography and DE-CTA of the pelvis and lower extremities. CTA data were postprocessed with two different applications: conventional bone removal and dual-energy bone removal. All data were reconstructed and evaluated as 3D maximum-intensity projections. Time requirements for reconstruction were documented. Sensitivity, specificity, accuracy, and concordance of DE-CTA regarding degree of stenosis and vessel wall calcification were calculated. A total of 359 vascular segments were analyzed. Compared with digital subtraction angiography, sensitivity, specificity, and accuracy, respectively, of CTA was 97.2%, 94.1%, and 94.7% by the dual-energy bone removal technique. The conventional bone removal tool delivered a sensitivity of 77.1%, a specificity of 70.7%, and an accuracy of 72.0%. Best results for both postprocessing methods were achieved in the vascular segments of the upper leg. In severely calcified segments, sensitivity, specificity, and accuracy stayed above 90% by the dual-energy bone removal technique, whereas the conventional bone removal technique showed a substantial decrease of sensitivity, specificity, and accuracy. DE-CTA is a feasible and accurate diagnostic method in the assessment of symptomatic peripheral arterial occlusive disease. Results obtained by DE-CTA are superior to the conventional bone removal technique and less dependent on vessel wall calcifications.

Entities:  

Mesh:

Year:  2009        PMID: 19130122     DOI: 10.1007/s00270-008-9491-5

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  23 in total

1.  [Disappearing borders between the disciplines vascular surgery and interventional radiology from the perspective of vascular surgeons].

Authors:  E S Debus
Journal:  Chirurg       Date:  2010-12       Impact factor: 0.955

2.  Subtraction CT angiography for the diagnosis of iliac arterial steno-occlusive disease.

Authors:  Michiko Suzuki; Ryoichi Tanaka; Kunihiro Yoshioka; Akihiko Abiko; Shigeru Ehara
Journal:  Jpn J Radiol       Date:  2015-12-18       Impact factor: 2.374

Review 3.  Multiplexed imaging in cancer diagnosis: applications and future advances.

Authors:  Hisataka Kobayashi; Michelle R Longmire; Mikako Ogawa; Peter L Choyke; Satomi Kawamoto
Journal:  Lancet Oncol       Date:  2010-03-24       Impact factor: 41.316

Review 4.  Peripheral artery disease. Part 1: clinical evaluation and noninvasive diagnosis.

Authors:  Joe F Lau; Mitchell D Weinberg; Jeffrey W Olin
Journal:  Nat Rev Cardiol       Date:  2011-05-31       Impact factor: 32.419

5.  Dual-energy CT angiography in peripheral arterial occlusive disease-accuracy of maximum intensity projections in clinical routine and subgroup analysis.

Authors:  Thomas Kau; Wolfgang Eicher; Christian Reiterer; Martin Niedermayer; Egon Rabitsch; Birgit Senft; Klaus A Hausegger
Journal:  Eur Radiol       Date:  2011-03-02       Impact factor: 5.315

6.  Dual-energy CT after peri-interventional subarachnoid haemorrhage: a feasibility study.

Authors:  C Brockmann; J Scharf; I S Nölte; M Seiz; C Groden; M A Brockmann
Journal:  Clin Neuroradiol       Date:  2010-11-04       Impact factor: 3.649

7.  Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT.

Authors:  Naoki Takahashi; Terri J Vrtiska; Akira Kawashima; Robert P Hartman; Andrew N Primak; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

8.  Off-resonance magnetic resonance angiography improves visualization of in-stent lumen in peripheral nitinol stents compared to conventional T1-weighted acquisitions: an in vitro comparison study.

Authors:  Gitsios Gitsioudis; Philipp Fortner; Matthias Stuber; Anna Missiou; Florian Andre; Oliver J Müller; Hugo A Katus; Grigorios Korosoglou
Journal:  Int J Cardiovasc Imaging       Date:  2016-08-17       Impact factor: 2.357

9.  Dual-source dual-energy CT with additional tin filtration: Dose and image quality evaluation in phantoms and in vivo.

Authors:  Andrew N Primak; Juan Carlos Ramirez Giraldo; Christian D Eusemann; Bernhard Schmidt; Birgit Kantor; Joel G Fletcher; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2010-11       Impact factor: 3.959

10.  Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast.

Authors:  Moritz H Albrecht; Jan-Erik Scholtz; Kristina Hüsers; Martin Beeres; Andreas M Bucher; Moritz Kaup; Simon S Martin; Sebastian Fischer; Boris Bodelle; Ralf W Bauer; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2015-09-03       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.