Literature DB >> 19089430

Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary angiography (NIMISCAD-Non Invasive Multicenter Italian Study for Coronary Artery Disease).

Riccardo Marano1, Francesco De Cobelli, Irene Floriani, Christoph Becker, Christopher Herzog, Maurizio Centonze, Giovanni Morana, Gian Franco Gualdi, Guido Ligabue, Gianluca Pontone, Carlo Catalano, Dante Chiappino, Massimo Midiri, Giovanni Simonetti, Filippo Marchisio, Lucio Olivetti, Rossella Fattori, Lorenzo Bonomo, Alessandro Del Maschio.   

Abstract

This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (> or =16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85-0.95), 0.91 (95% CI 0.86-0.95), 0.94 (95% CI 0.89-0.97), 0.88 (95% CI 0.81-0.93), and 0.91 (95% CI 0.88-0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), and 0.82 (95% CI 0.77-0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines. Aldrovandi Annachiara

Entities:  

Mesh:

Year:  2008        PMID: 19089430     DOI: 10.1007/s00330-008-1239-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  41 in total

1.  Coronary angiography with multi-slice computed tomography.

Authors:  K Nieman; M Oudkerk; B J Rensing; P van Ooijen; A Munne; R J van Geuns; P J de Feyter
Journal:  Lancet       Date:  2001-02-24       Impact factor: 79.321

2.  Performance evaluation of a multi-slice CT system with 16-slice detector and increased gantry rotation speed for isotropic submillimeter imaging of the heart.

Authors:  Thomas Flohr; Axel Küttner; Herbert Bruder; Karl Stierstorfer; Sandra S Halliburton; Stefan Schaller; Bernd M Ohnesorge
Journal:  Herz       Date:  2003-02       Impact factor: 1.443

3.  Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography.

Authors:  Mariko Ehara; Jean-Francois Surmely; Masato Kawai; Osamu Katoh; Tetsuo Matsubara; Mitsuyasu Terashima; Etsuo Tsuchikane; Yoshihisa Kinoshita; Tomomichi Suzuki; Tatsuya Ito; Yoshihiro Takeda; Kenya Nasu; Nobuyoshi Tanaka; Akira Murata; Yasuyuki Suzuki; Koyo Sato; Takahiko Suzuki
Journal:  Circ J       Date:  2006-05       Impact factor: 2.993

4.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

5.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

6.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

Authors:  Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders
Journal:  Eur J Radiol       Date:  2006-01-19       Impact factor: 3.528

7.  Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography.

Authors:  Oliver Gaemperli; Tiziano Schepis; Victor Kalff; Mehdi Namdar; Ines Valenta; Laurent Stefani; Lotus Desbiolles; Sebastian Leschka; Lars Husmann; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-01-24       Impact factor: 9.236

8.  Correlation of coronary calcification and angiographically documented stenoses in patients with suspected coronary artery disease: results of 1,764 patients.

Authors:  R Haberl; A Becker; A Leber; A Knez; C Becker; C Lang; R Brüning; M Reiser; G Steinbeck
Journal:  J Am Coll Cardiol       Date:  2001-02       Impact factor: 24.094

9.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

10.  Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease.

Authors:  Uchechukwu K Sampson; Sharmila Dorbala; Atul Limaye; Raymond Kwong; Marcelo F Di Carli
Journal:  J Am Coll Cardiol       Date:  2007-02-26       Impact factor: 24.094

View more
  22 in total

1.  Clinical indications for cardiac computed tomography. From the Working Group of the Cardiac Radiology Section of the Italian Society of Medical Radiology (SIRM).

Authors:  E di Cesare; I Carbone; A Carriero; M Centonze; F De Cobelli; R De Rosa; P Di Renzi; A Esposito; R Faletti; R Fattori; M Francone; A Giovagnoni; L La Grutta; G Ligabue; L Lovato; R Marano; M Midiri; L Natale; A Romagnoli; V Russo; F Sardanelli; F Cademartiri
Journal:  Radiol Med       Date:  2012-04-01       Impact factor: 3.469

Review 2.  Low dose CT of the heart: a quantum leap into a new era of cardiovascular imaging.

Authors:  E Maffei; C Martini; S De Crescenzo; T Arcadi; A Clemente; E Capuano; A Rossi; R Malagò; N Mollet; A Weustink; C Tedeschi; L La Grutta; S Seitun; A Igoren Guaricci; F Cademartiri
Journal:  Radiol Med       Date:  2010-06-23       Impact factor: 3.469

3.  Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

Authors:  Sabine Schueler; Stefan Walther; Georg M Schuetz; Peter Schlattmann; Marc Dewey
Journal:  Eur Radiol       Date:  2013-01-16       Impact factor: 5.315

4.  Is coronary CT angiography useful in diagnosing acute coronary syndromes in the Emergency Department?

Authors:  Franca Dipaola; Francesca Perego
Journal:  Intern Emerg Med       Date:  2013-03-27       Impact factor: 3.397

Review 5.  Practical instructions for using drugs in CT and MR cardiac imaging.

Authors:  Giuseppe Rovere; Agostino Meduri; Giancarlo Savino; Francesco Ciriaco Flammia; Francesca Lo Piccolo; Maria Rachele Pia Carafa; Anna Rita Larici; Luigi Natale; Biagio Merlino; Riccardo Marano
Journal:  Radiol Med       Date:  2020-08-24       Impact factor: 3.469

6.  MDCT assessment of CAD in type-2 diabetic subjects with diabetic neuropathy: the role of Charcot neuro-arthropathy.

Authors:  Riccardo Marano; Dario Pitocco; Enrico Di Stasio; Giancarlo Savino; Biagio Merlino; Carlo Trani; Federica Pirro; Claudia Rutigliano; Carolina Santangelo; Aurelian Costin Minoiu; Luigi Natale; Lorenzo Bonomo
Journal:  Eur Radiol       Date:  2015-07-03       Impact factor: 5.315

7.  Diagnostic accuracy of 64-slice computed tomography coronary angiography in a large population of patients without revascularisation: registry data and review of multicentre trials.

Authors:  E Maffei; A Palumbo; C Martini; W Meijboom; C Tedeschi; P Spagnolo; A Zuccarelli; A Weustink; T Torri; N Mollet; S Seitun; G P Krestin; F Cademartiri
Journal:  Radiol Med       Date:  2009-12-16       Impact factor: 3.469

8.  Cost-effectiveness of computed tomography coronary angiography versus conventional invasive coronary angiography.

Authors:  Meryl Darlington; Pascal Gueret; Jean-Pierre Laissy; Antoine Filipovic Pierucci; Hassani Maoulida; Céline Quelen; Ralph Niarra; Gilles Chatellier; Isabelle Durand-Zaleski
Journal:  Eur J Health Econ       Date:  2014-07-03

9.  Coronary calcium score and computed tomography coronary angiography in high-risk asymptomatic subjects: assessment of diagnostic accuracy and prevalence of non-obstructive coronary artery disease.

Authors:  Filippo Cademartiri; Erica Maffei; Alessandro Palumbo; Sara Seitun; Chiara Martini; Carlo Tedeschi; Ludovico La Grutta; Massimo Midiri; Annick C Weustink; Nico R Mollet; Gabriel P Krestin
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

10.  Coronary CT angiography versus standard evaluation in acute chest pain.

Authors:  Udo Hoffmann; Quynh A Truong; David A Schoenfeld; Eric T Chou; Pamela K Woodard; John T Nagurney; J Hector Pope; Thomas H Hauser; Charles S White; Scott G Weiner; Shant Kalanjian; Michael E Mullins; Issam Mikati; W Frank Peacock; Pearl Zakroysky; Douglas Hayden; Alexander Goehler; Hang Lee; G Scott Gazelle; Stephen D Wiviott; Jerome L Fleg; James E Udelson
Journal:  N Engl J Med       Date:  2012-07-26       Impact factor: 91.245

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.