BACKGROUND: 4-slice CT scanners have shown limitations in clinical application for noninvasive coronary CT angiography (CTA). We evaluate advances in ECG-gated scanning of the heart and the coronary arteries with recently introduced 16-slice CT equipment (SOMATOM Sensation 16, Siemens, Forchheim, Germany). MATERIALS AND METHODS: The technical principles of ECG-gated cardiac scanning, scan parameters, and detector design of the new scanner are presented. ECG-gated scan and image reconstruction techniques and ECG-controlled dose modulation ("ECG pulsing") for a reduction of the patient dose are described, key parameters for image quality and simulation results presented, and phantom studies and initial patient experience discussed. The impact of reduced gantry rotation time (0.42 s) on temporal resolution and initial estimations of the patient dose are presented. RESULTS: Extensions of ECG-gated reconstruction algorithms used for 4-slice CT provide adequate image quality for up to 16 slices. For each detector collimation different slice widths are available for retrospective reconstruction with well-defined slice sensitivity profiles (SSPs). For coronary CTA the heart can be covered with 0.75 mm collimation within a 20-s breathhold. The best possible spatial resolution is 0.5 x 0.5 x 0.6 mm. For 0.42 s gantry rotation time, temporal resolution reaches its optimum (105 ms) at a heart rate of 81 bpm. Effective patient dose for coronary CTA is 4-5 mSv using ECG-pulsed acquisition. CONCLUSION: The clinical performance of coronary CTA by means of spatial resolution, temporal resolution and scan time is substantially improved with the evaluated 16-slice CT scanner. Also, display of smaller coronary segments and instent visualization are substantially improved.
BACKGROUND: 4-slice CT scanners have shown limitations in clinical application for noninvasive coronary CT angiography (CTA). We evaluate advances in ECG-gated scanning of the heart and the coronary arteries with recently introduced 16-slice CT equipment (SOMATOM Sensation 16, Siemens, Forchheim, Germany). MATERIALS AND METHODS: The technical principles of ECG-gated cardiac scanning, scan parameters, and detector design of the new scanner are presented. ECG-gated scan and image reconstruction techniques and ECG-controlled dose modulation ("ECG pulsing") for a reduction of the patient dose are described, key parameters for image quality and simulation results presented, and phantom studies and initial patient experience discussed. The impact of reduced gantry rotation time (0.42 s) on temporal resolution and initial estimations of the patient dose are presented. RESULTS: Extensions of ECG-gated reconstruction algorithms used for 4-slice CT provide adequate image quality for up to 16 slices. For each detector collimation different slice widths are available for retrospective reconstruction with well-defined slice sensitivity profiles (SSPs). For coronary CTA the heart can be covered with 0.75 mm collimation within a 20-s breathhold. The best possible spatial resolution is 0.5 x 0.5 x 0.6 mm. For 0.42 s gantry rotation time, temporal resolution reaches its optimum (105 ms) at a heart rate of 81 bpm. Effective patient dose for coronary CTA is 4-5 mSv using ECG-pulsed acquisition. CONCLUSION: The clinical performance of coronary CTA by means of spatial resolution, temporal resolution and scan time is substantially improved with the evaluated 16-slice CT scanner. Also, display of smaller coronary segments and instent visualization are substantially improved.
Authors: Christopher Herzog; Selami Dogan; Gerhard Wimmer-Greinecker; Joern O Balzer; Martin G Mack; Thomas J Vogl Journal: Eur Radiol Date: 2003-12 Impact factor: 5.315
Authors: P G C Begemann; U van Stevendaal; R Manzke; A Stork; F Weiss; C Nolte-Ernsting; M Grass; G Adam Journal: Eur Radiol Date: 2005-01-21 Impact factor: 5.315
Authors: Helge von Kiedrowski; Marcus Wiemer; Krista Franzke; Rainer Preuss; Bernhard Vaske; Thomas Butz; Olaf Oldenburg; Thomas Bitter; Khalid Mahmood; Wolfram Burchert; Dieter Horstkotte; Christoph Langer Journal: Int J Cardiovasc Imaging Date: 2008-09-01 Impact factor: 2.357
Authors: Riccardo Marano; Francesco De Cobelli; Irene Floriani; Christoph Becker; Christopher Herzog; Maurizio Centonze; Giovanni Morana; Gian Franco Gualdi; Guido Ligabue; Gianluca Pontone; Carlo Catalano; Dante Chiappino; Massimo Midiri; Giovanni Simonetti; Filippo Marchisio; Lucio Olivetti; Rossella Fattori; Lorenzo Bonomo; Alessandro Del Maschio Journal: Eur Radiol Date: 2008-12-17 Impact factor: 5.315