A convenient alignment approach for x-ray imaging experiments based on laser positioning devices.

Zhang Da1, Molly Donovan, Xizeng Wu, Hong Liu.   

Abstract

This study presents a two-laser alignment approach for facilitating the precise alignment of various imaging and measuring components with respect to the x-ray beam. The first laser constantly pointed to the output window of the source, in a direction parallel to the path along which the components are placed. The second laser beam, originating from the opposite direction, was calibrated to coincide with the first laser beam. Thus, a visible indicator of the direction of the incident x-ray beam was established, and the various components could then be aligned conveniently and accurately with its help.

Mesh:

Substances:

Year:  2008        PMID: 19070224      PMCID: PMC2673597          DOI: 10.1118/1.2989059

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  An alignment method for mammographic X-ray spectroscopy under clinical conditions.

Authors:  S Miyajima; K Imagawa; M Matsumoto
Journal:  Br J Radiol       Date:  2002-09       Impact factor: 3.039

2.  Laser alignment system for high-quality portable radiography.

Authors:  H MacMahon; N J Yasillo; M Carlin
Journal:  Radiographics       Date:  1992-01       Impact factor: 5.333

3.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

4.  Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy.

Authors:  U Bottigli; B Golosio; G L Masala; P Oliva; S Stumbo; P Delogu; M E Fantacci; L Abbene; F Fauci; G Raso
Journal:  Med Phys       Date:  2006-09       Impact factor: 4.071

5.  Determination of x-ray tube focal spot position.

Authors:  H Kubota; Y Ozaki; M Matsumoto; H Kanamori
Journal:  Med Phys       Date:  1993 Jul-Aug       Impact factor: 4.071

6.  Alignment of x-ray tube focal spots for spectral measurement.

Authors:  K Nishizawa; H Maekoshi; Y Kamiya; Y Kobayashi; K Ohara; S Sakuma
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

7.  A megavoltage MTF measurement technique for metal screen-film detectors.

Authors:  R T Droege
Journal:  Med Phys       Date:  1979 Jul-Aug       Impact factor: 4.071

8.  Experimental study of the photon energy spectrum of primary diagnostic x-rays.

Authors:  E R Epp; H Weiss
Journal:  Phys Med Biol       Date:  1966-04       Impact factor: 3.609

9.  A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors.

Authors:  Ivan A Brezovich; Stephen Jordan
Journal:  J Appl Clin Med Phys       Date:  2007-10-10       Impact factor: 2.102

  9 in total
  6 in total

1.  A phantom-based calibration method for digital x-ray tomosynthesis.

Authors:  Hui Miao; Xizeng Wu; Huijuan Zhao; Hong Liu
Journal:  J Xray Sci Technol       Date:  2012       Impact factor: 1.535

2.  Use of a laser-guided collimation system to perform direct kilovoltage x-ray spectra measurements on a linear accelerator onboard imager.

Authors:  Zachary Grelewicz; Andrew H Belcher; Rodney D Wiersma
Journal:  Med Phys       Date:  2018-10-09       Impact factor: 4.071

3.  Dose and detectability improvements with high energy phase sensitive x-ray imaging in comparison to low energy conventional imaging.

Authors:  Molly Donovan Wong; Aimin Yan; Muhammad Ghani; Yuhua Li; Laurie Fajardo; Xizeng Wu; Hong Liu
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

4.  Image quality and dose efficiency of high energy phase sensitive x-ray imaging: phantom studies.

Authors:  Molly Donovan Wong; Xizeng Wu; Hong Liu
Journal:  J Xray Sci Technol       Date:  2014       Impact factor: 1.535

5.  Practical alignment method for X-ray spectral measurement in micro-CT system based on 3D printing technology.

Authors:  Liqiang Ren; Di Wu; Yuhua Li; Bin Zheng; Yong Chen; Kai Yang; Hong Liu
Journal:  Biomed Phys Eng Express       Date:  2016-07-15

6.  The effects of x-ray beam hardening on detective quantum efficiency and radiation dose.

Authors:  Molly Donovan Wong; Xizeng Wu; Hong Liu
Journal:  J Xray Sci Technol       Date:  2011       Impact factor: 1.535

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.