Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy.

U Bottigli1, B Golosio, G L Masala, P Oliva, S Stumbo, P Delogu, M E Fantacci, L Abbene, F Fauci, G Raso.   

Abstract

We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detector allowed its use with a larger pinhole collimator than could be used with the CZT detector. Additionally, the improved pinhole collimator and alignment features of the apparatus permitted much more rapid setup for acquisition of x-ray spectra than was possible on the system described in the earlier work. These improvements in detector technology, collimation and ease of alignment, as well as low cost, make this apparatus attractive as a tool for both laboratory research and advanced mammography quality control.

Entities:  

Mesh:

Year:  2006        PMID: 17022243     DOI: 10.1118/1.2229431

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  A convenient alignment approach for x-ray imaging experiments based on laser positioning devices.

Authors:  Zhang Da; Molly Donovan; Xizeng Wu; Hong Liu
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

2.  Use of a laser-guided collimation system to perform direct kilovoltage x-ray spectra measurements on a linear accelerator onboard imager.

Authors:  Zachary Grelewicz; Andrew H Belcher; Rodney D Wiersma
Journal:  Med Phys       Date:  2018-10-09       Impact factor: 4.071

3.  Breast tissue decomposition with spectral distortion correction: a postmortem study.

Authors:  Huanjun Ding; Bo Zhao; Pavlo Baturin; Farnaz Behroozi; Sabee Molloi
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

4.  Practical alignment method for X-ray spectral measurement in micro-CT system based on 3D printing technology.

Authors:  Liqiang Ren; Di Wu; Yuhua Li; Bin Zheng; Yong Chen; Kai Yang; Hong Liu
Journal:  Biomed Phys Eng Express       Date:  2016-07-15

5.  Image-based spectral distortion correction for photon-counting x-ray detectors.

Authors:  Huanjun Ding; Sabee Molloi
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

6.  Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications.

Authors:  Stefano Del Sordo; Leonardo Abbene; Ezio Caroli; Anna Maria Mancini; Andrea Zappettini; Pietro Ubertini
Journal:  Sensors (Basel)       Date:  2009-05-12       Impact factor: 3.576

7.  Direct measurement of mammographic X-ray spectra with a digital CdTe detection system.

Authors:  Leonardo Abbene; Gaetano Gerardi; Fabio Principato; Stefano Del Sordo; Giuseppe Raso
Journal:  Sensors (Basel)       Date:  2012-06-18       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.