Literature DB >> 19050571

Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement.

Jin S Yeom1, Jacob M Buchowski, Kun-Woo Park, Bong-Soon Chang, Choon-Ki Lee, K Daniel Riew.   

Abstract

STUDY
DESIGN: Prospective consecutive case series.
OBJECTIVE: To identify the incidence of undetected vertebral artery groove and foramen violations and arterial injuries during placement of C1 lateral mass and C2 pedicle screws. SUMMARY OF BACKGROUND DATA: Although insertion of C1 lateral mass and C2 pedicle screws has become increasingly common, we are unaware of any report that has specifically examined postoperative CT scans with CT angiography to determine the incidence of undetected neurovascular violations during insertion of these screws.
METHODS: Twenty-three consecutive patients were examined after upper cervical screw fixation was performed under fluoroscopic guidance. In all patients, intraoperative clinical findings, fluoroscopic images, and postoperative radiographs were reviewed. Thin-cut CT scans and CT angiography with multiplanar and three-dimensional reconstruction were used to detect cortical breaches and arterial injuries.
RESULTS: A total of 85 screws, including 39 C1 lateral mass, 39 C2 pedicle, and 7 C2 laminar screws were inserted. No apparent neurologic or arterial injuries were noted. However, CT scans revealed that 8 C2 pedicle screws (21%) resulted in vertebral artery groove violations. None resulted in arterial injury. Two C1 screws (5%) had errant trajectories. One breached the medial wall of the lateral mass and the other breached the vertebral artery foramen, causing arterial occlusion as seen on CT angiography. None of the violations were detected intraoperatively or on postoperative plain radiographs with the exception of 1 C1 medial breach observed on a postoperative open-mouth view.
CONCLUSION: Although vertebral artery groove and foramen violations were relatively common on postoperative CT scans, none were detected intraoperatively or on postoperative radiographs. Most alarmingly, 1 vertebral artery injury was undetected intraoperatively. Since a vertebral injury can be potentially catastrophic, this study emphasizes the inherent dangers associated with placement of C1 and C2 screws and underscores the importance of careful postoperative evaluation and surgical technique when inserting these screws.

Entities:  

Mesh:

Year:  2008        PMID: 19050571     DOI: 10.1097/BRS.0b013e3181870441

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  20 in total

1.  Endovascular treatment of vertebral artery injury during cervical posterior fusion (C1 lateral mass screw). A case report.

Authors:  Kyeong-Wook Yoon; Jung-Ho Ko; Chun-Sung Cho; Sang-Koo Lee; Young-Joon Kim; Young Jin Kim
Journal:  Interv Neuroradiol       Date:  2013-09-26       Impact factor: 1.610

2.  Pedicle versus laminar screws: what provides more suitable C2 fixation in congenital C2-3 fusion patients?

Authors:  Shenglin Wang; Chao Wang; Peter G Passias; Ming Yan; Haitao Zhou
Journal:  Eur Spine J       Date:  2010-05-04       Impact factor: 3.134

3.  Surgical treatment for atlantooccipital osteoarthritis: a case report of two patients.

Authors:  Hiroyuki Yoshihara; Christopher Kepler; Kazuhiro Hasegawa; Bernard A Rawlins
Journal:  Eur Spine J       Date:  2010-12-02       Impact factor: 3.134

4.  Evaluation of vertebral artery anomaly in basilar invagination and prevention of vascular injury during surgical intervention: CTA features and analysis.

Authors:  Shuaishuai Xu; Shidong Ruan; Xiaoyu Song; Jinyu Yu; Jianrong Xu; Ruozhen Gong
Journal:  Eur Spine J       Date:  2017-12-29       Impact factor: 3.134

Review 5.  Modern instrumentation of the pediatric occiput and upper cervical spine: review article.

Authors:  Daniel Hedequist
Journal:  HSS J       Date:  2014-08-12

6.  In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III).

Authors:  Heiko Koller; Wolfgang Hitzl; Frank Acosta; Mark Tauber; Juliane Zenner; Herbert Resch; Yasutsugu Yukawa; Oliver Meier; Rene Schmidt; Michael Mayer
Journal:  Eur Spine J       Date:  2009-07-03       Impact factor: 3.134

7.  Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients.

Authors:  Xueshi Li; Fuzhi Ai; Hong Xia; Zenghui Wu; Xiangyang Ma; Qingshui Yin
Journal:  Eur Spine J       Date:  2014-05-17       Impact factor: 3.134

8.  Atlanto-axial rotary instability (Fielding type 1): characteristic clinical and radiological findings, and treatment outcomes following alignment, fusion, and stabilization.

Authors:  Fraser C Henderson; Robert Rosenbaum; Malini Narayanan; Myles Koby; Kelly Tuchman; Peter C Rowe; Clair Francomano
Journal:  Neurosurg Rev       Date:  2020-07-04       Impact factor: 3.042

9.  Surgical treatment of adult and pediatric C1/C2 subluxation with intraoperative computed tomography guidance.

Authors:  Ji Min Ling; Rajendra Tiruchelvarayan; Wan T Seow; Hua Bi Ng
Journal:  Surg Neurol Int       Date:  2013-03-22

10.  An anatomic consideration of C2 vertebrae artery groove variation for individual screw implantation in axis.

Authors:  Janhua Wang; Hong Xia; Qingshui Ying; Yang Lu; Zenghui Wu; Fzhi Ai; Xiangyang Ma
Journal:  Eur Spine J       Date:  2013-05-10       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.