Literature DB >> 24838426

Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients.

Xueshi Li1, Fuzhi Ai, Hong Xia, Zenghui Wu, Xiangyang Ma, Qingshui Yin.   

Abstract

PURPOSE: To investigate the (1) radiographic and clinical accuracy of C1 anterior lateral mass screw (C1ALMS) and C2 anterior pedicle screw (C2APS) placement in the transoral atlantoaxial reduction plate (TARP)-III procedure, (2) screw insertion-associated clinical complications and (3) fusion status between C1 and C2.
METHODS: Radiographic and clinical data were obtained from the electronic medical record system. Studies were carried out to assess the accuracy of C1ALMS and C2APS placement, the screw insertion-associated clinical complications and the fusion status between C1 and C2. Placement of the screws was assessed using the modified All India Institute of Medical Sciences outcome-based classification.
RESULTS: Two-hundred and twelve C1ALMS and 207 C2APS in 106 patients were assessed. The ideal accurate rates were 92.0% (195) and 53.1% (110), and the acceptable accurate rates were 97.6% (207) and 87.0% (180), respectively. One patient died postoperatively due to C2 screw misplacement. There were no symptoms of neurologic and vertebral artery injuries in the rest of the patients. 102 patients (97.1%) achieved solid fusion between C1 and C2. No instrumentation failure due to delayed union or nonunion was observed.
CONCLUSION: C1ALMS placement in TARP-III procedures appears to be safe. The cortical breach rate of C2APS is high though clinically the neurovascular complication rate is similar to that of posterior atlantoaxial procedures. Advanced navigation strategies may help improve the accuracy of C2APS placement and decrease potential complications.

Entities:  

Mesh:

Year:  2014        PMID: 24838426     DOI: 10.1007/s00586-014-3353-4

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  27 in total

1.  Radiographic evaluation of the technique for C1 lateral mass and C2 pedicle screw fixation in three hundred nineteen cases.

Authors:  Shenglin Wang; Chao Wang; Kirkham B Wood; Ming Yan; Haitao Zhou
Journal:  Spine (Phila Pa 1976)       Date:  2011-01-01       Impact factor: 3.468

2.  Transoral atlantoaxial reduction plate internal fixation for the treatment of irreducible atlantoaxial dislocation: a 2- to 4-year follow-up.

Authors:  Qing-shui Yin; Fu-zhi Ai; Kai Zhang; Xiao-hong Mai; Hong Xia; Zeng-hui Wu
Journal:  Orthop Surg       Date:  2010-05       Impact factor: 2.071

3.  Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study.

Authors:  Milan K Sen; Thomas Steffen; Lorne Beckman; Anthony Tsantrizos; Rudolph Reindl; Max Aebi
Journal:  Eur Spine J       Date:  2005-01-25       Impact factor: 3.134

4.  Posterior C2 instrumentation: accuracy and complications associated with four techniques.

Authors:  Richard J Bransford; Anthony J Russo; Mark Freeborn; Quynh T Nguyen; Michael J Lee; Jens R Chapman; Carlo Bellabarba
Journal:  Spine (Phila Pa 1976)       Date:  2011-06-15       Impact factor: 3.468

5.  Minimally invasive anterior transarticular screw fixation and microendoscopic bone graft for atlantoaxial instability.

Authors:  Jian Wang; Yue Zhou; ZhengFeng Zhang; ChangQing Li; WenJie Zheng; Yuan Zhang
Journal:  Eur Spine J       Date:  2012-08       Impact factor: 3.134

6.  Outcome-based classification for assessment of thoracic pedicular screw placement.

Authors:  Bidre N Upendra; Devkant Meena; Buddhadev Chowdhury; Abrar Ahmad; Arvind Jayaswal
Journal:  Spine (Phila Pa 1976)       Date:  2008-02-15       Impact factor: 3.468

7.  Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement.

Authors:  Jin S Yeom; Jacob M Buchowski; Kun-Woo Park; Bong-Soon Chang; Choon-Ki Lee; K Daniel Riew
Journal:  Spine (Phila Pa 1976)       Date:  2008-12-01       Impact factor: 3.468

8.  Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study.

Authors:  Florian Fensky; Rebecca A Kueny; Kay Sellenschloh; Klaus Püschel; Michael M Morlock; Johannes M Rueger; Wolfgang Lehmann; Gerd Huber; Nils Hansen-Algenstaedt
Journal:  Eur Spine J       Date:  2013-12-31       Impact factor: 3.134

9.  Open reduction of irreducible atlantoaxial dislocation by transoral anterior atlantoaxial release and posterior internal fixation.

Authors:  Chao Wang; Ming Yan; Hai Tao Zhou; Sheng Lin Wang; Geng Ting Dang
Journal:  Spine (Phila Pa 1976)       Date:  2006-05-15       Impact factor: 3.468

10.  Translaminar versus pedicle screw fixation of C2: comparison of surgical morbidity and accuracy of 313 consecutive screws.

Authors:  Scott L Parker; Matthew J McGirt; Giannina L Garcés-Ambrossi; Vivek A Mehta; Daniel M Sciubba; Timothy F Witham; Ziya L Gokaslan; Jean-Paul Wolinksy
Journal:  Neurosurgery       Date:  2009-05       Impact factor: 4.654

View more
  2 in total

1.  Biomechanical comparison of a novel transoral atlantoaxial anchored cage with established fixation technique - a finite element analysis.

Authors:  Bao-cheng Zhang; Hai-bo Liu; Xian-hua Cai; Zhi-hua Wang; Feng Xu; Hui Kang; Ran Ding; Xiao-qing Luo
Journal:  BMC Musculoskelet Disord       Date:  2015-09-22       Impact factor: 2.362

Review 2.  Preoperative management and postoperative complications associated with transoral decompression for the upper cervical spine.

Authors:  Wenqiang Li; Bingjin Wang; Xiaobo Feng; Wenbin Hua; Cao Yang
Journal:  BMC Musculoskelet Disord       Date:  2022-02-08       Impact factor: 2.362

  2 in total