Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging.

W Liu1, R D Wiersma, W Mao, G Luxton, L Xing.   

Abstract

To minimize the adverse dosimetric effect caused by tumor motion, it is desirable to have real-time knowledge of the tumor position throughout the beam delivery process. A promising technique to realize the real-time image guided scheme in external beam radiation therapy is through the combined use of MV and onboard kV beam imaging. The success of this MV-kV triangulation approach for fixed-gantry radiation therapy has been demonstrated. With the increasing acceptance of modern arc radiotherapy in the clinics, a timely and clinically important question is whether the image guidance strategy can be extended to arc therapy to provide the urgently needed real-time tumor motion information. While conceptually feasible, there are a number of theoretical and practical issues specific to the arc delivery that need to be resolved before clinical implementation. The purpose of this work is to establish a robust procedure of system calibration for combined MV and kV imaging for internal marker tracking during arc delivery and to demonstrate the feasibility and accuracy of the technique. A commercially available LINAC equipped with an onboard kV imager and electronic portal imaging device (EPID) was used for the study. A custom built phantom with multiple ball bearings was used to calibrate the stereoscopic MV-kV imaging system to provide the transformation parameters from imaging pixels to 3D world coordinates. The accuracy of the fiducial tracking system was examined using a 4D motion phantom capable of moving in accordance with a pre-programmed trajectory. Overall, spatial accuracy of MV-kV fiducial tracking during the arc delivery process for normal adult breathing amplitude and period was found to be better than 1 mm. For fast motion, the results depended on the imaging frame rates. The RMS error ranged from approximately 0.5 mm for the normal adult breathing pattern to approximately 1.5 mm for more extreme cases with a low imaging frame rate of 3.4 Hz. In general, highly accurate real-time tracking of implanted markers using hybrid MV-kV imaging is achievable and the technique should be useful to improve the beam targeting accuracy of arc therapy.

Entities:  

Mesh:

Year:  2008        PMID: 19043177     DOI: 10.1088/0031-9155/53/24/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  Optimized hybrid megavoltage-kilovoltage imaging protocol for volumetric prostate arc therapy.

Authors:  Wu Liu; Rodney D Wiersma; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-05-14       Impact factor: 7.038

2.  Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields.

Authors:  Yunzhi Ma; Louis Lee; O Keshet; Paul Keall; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

3.  A Bayesian approach to real-time 3D tumor localization via monoscopic x-ray imaging during treatment delivery.

Authors:  Ruijiang Li; Benjamin P Fahimian; Lei Xing
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

4.  A comprehensive study of the mechanical performance of gantry, EPID and the MLC assembly in Elekta linacs during gantry rotation.

Authors:  P Rowshanfarzad; H L Riis; S J Zimmermann; M A Ebert
Journal:  Br J Radiol       Date:  2015-04-23       Impact factor: 3.039

5.  Optimizing fiducial visibility on periodically acquired megavoltage and kilovoltage image pairs during prostate volumetric modulated arc therapy.

Authors:  Pengpeng Zhang; Laura Happersett; Bosky Ravindranath; Michael Zelefsky; Gig Mageras; Margie Hunt
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

6.  Markerless Pancreatic Tumor Target Localization Enabled By Deep Learning.

Authors:  Wei Zhao; Liyue Shen; Bin Han; Yong Yang; Kai Cheng; Diego A S Toesca; Albert C Koong; Daniel T Chang; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2019-06-13       Impact factor: 7.038

Review 7.  Review of Real-Time 3-Dimensional Image Guided Radiation Therapy on Standard-Equipped Cancer Radiation Therapy Systems: Are We at the Tipping Point for the Era of Real-Time Radiation Therapy?

Authors:  Paul J Keall; Doan Trang Nguyen; Ricky O'Brien; Pengpeng Zhang; Laura Happersett; Jenny Bertholet; Per R Poulsen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-04-14       Impact factor: 7.038

8.  Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters.

Authors:  Warren G Campbell; Moyed Miften; Bernard L Jones
Journal:  Med Phys       Date:  2017-02       Impact factor: 4.071

9.  Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--experiments, simulation, and dosimetry study.

Authors:  Wu Liu; Jianguo Qian; Steven L Hancock; Lei Xing; Gary Luxton
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

10.  Intrafractional 3D localization using kilovoltage digital tomosynthesis for sliding-window intensity modulated radiation therapy.

Authors:  Pengpeng Zhang; Margie Hunt; Hai Pham; Grace Tang; Gig Mageras
Journal:  Phys Med Biol       Date:  2015-08-25       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.