Literature DB >> 19039264

Respiratory motion detection and correction in ECG-gated SPECT: a new approach.

Ahmad Bitarafan1, Hossein Rajabi, Bernhard Gruy, Feridoon Rustgou, Ali Akbar Sharafi, Hasan Firoozabady, Nahid Yaghoobi, Hadi Malek, Christian Pirich, Werner Langesteger, Mohsen Beheshti.   

Abstract

OBJECTIVE: Gated myocardial perfusion single-photon emission computed tomography (GSPECT) has been established as an accurate and reproducible diagnostic and prognostic technique for the assessment of myocardial perfusion and function. Respiratory motion is among the major factors that may affect the quality of myocardial perfusion imaging (MPI) and consequently the accuracy of the examination. In this study, we have proposed a new approach for the tracking of respiratory motion and the correction of unwanted respiratory motion by the use of respiratory-cardiac gated-SPECT (RC-GSPECT). In addition, we have evaluated the use of RC-GSPECT for quantitative and visual assessment of myocardial perfusion and function.
MATERIALS AND METHODS: Twenty-six patients with known or suspected coronary artery disease (CAD)-underwent two-day stress and rest (99m)Tc-Tetrofosmin myocardial scintigraphy using both conventional GSPECT and RC-GSPECT methods. The respiratory signals were induced by use of a CT real-time position management (RPM) respiratory gating interface. A PIO-D144 card, which is transistor-transistor logic (TTL) compatible, was used as the input interface for simultaneous detection of both ECG and respiration signals.
RESULTS: A total of 26 patients with known or suspected CAD were examined in this study. Stress and rest myocardial respiratory motion in the vertical direction was 8.8-16.6 mm (mean, 12.4 +/- 2.9 mm) and 7.8-11.8 mm (mean, 9.5 +/- 1.6 mm), respectively. The percentages of tracer intensity in the inferior, inferoseptal and septal walls as well as the inferior to lateral (I/L) uptake ratio was significantly higher with the use of RC-GSPECT as compared to the use of GSPECT (p < 0.01). In a left ventricular ejection fraction (LVEF) correlation analysis between the use of rest GSPECT and RC-GSPECT with echocardiography, better correlation was noted between RC-GSPECT and echocardiography as compared with the use of GSPECT (y = 0.9654x + 1.6514; r = 0.93, p < 0.001 versus y = 0.8046x + 5.1704; r = 0.89, p < 0.001). Nineteen (19/26) patients (73.1%) showed abnormal myocardial perfusion scans with reversible regional myocardial defects; of the 19 patients, 14 (14/26) patients underwent coronary angiography.
CONCLUSION: Respiratory induced motion can be successfully corrected simultaneously with the use of ECG-gated SPECT in MPI studies using this proposed technique. Moreover, the use of ECG-gated SPECT improved image quality, especially in the inferior and septal regions that are mostly affected by diaphragmatic attenuation. However, the effect of respiratory correction depends mainly on the patient respiratory pattern and may be clinically relevant in certain cases.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19039264      PMCID: PMC2627236          DOI: 10.3348/kjr.2008.9.6.490

Source DB:  PubMed          Journal:  Korean J Radiol        ISSN: 1229-6929            Impact factor:   3.500


  23 in total

1.  A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging.

Authors:  P H Pretorius; M A King; B M Tsui; K J LaCroix; W Xia
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Development of respiratory gated myocardial SPECT system.

Authors:  K Cho; S Kumiata; S Okada; T Kumazaki
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

3.  Reduction of respiratory motion artifacts in PET imaging of lung cancer by respiratory correlated dynamic PET: methodology and comparison with respiratory gated PET.

Authors:  Sadek A Nehmeh; Yusuf E Erdi; Kenneth E Rosenzweig; Heiko Schoder; Steve M Larson; Olivia D Squire; John L Humm
Journal:  J Nucl Med       Date:  2003-10       Impact factor: 10.057

Review 4.  The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging.

Authors:  Vanessa Go; Mehul R Bhatt; Robert C Hendel
Journal:  J Nucl Med       Date:  2004-05       Impact factor: 10.057

5.  Monitoring of respiratory movement of the diaphragm for gated radiotherapy.

Authors:  Takuhito Tada; Masako Hosono; Tomio Fujioka; Haruyuki Fukuda; Toshifumi Nakajima; Yuichi Inoue
Journal:  Radiat Med       Date:  2005-02

6.  Combined quantitative supine-prone myocardial perfusion SPECT improves detection of coronary artery disease and normalcy rates in women.

Authors:  Piotr J Slomka; Hidetaka Nishina; Aiden Abidov; Sean W Hayes; John D Friedman; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

7.  Effects of spontaneous respiration on right and left ventricular function: evaluation by respiratory and ECG gated radionuclide ventriculography.

Authors:  B H Kim; Y Ishida; Y Tsuneoka; N Matsubara; T Hiraoka; H Takeda; M Inoue; T Kamada; K Kimura; T Kozuka
Journal:  J Nucl Med       Date:  1987-02       Impact factor: 10.057

8.  Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images.

Authors:  W G O'Dell; C C Moore; W C Hunter; E A Zerhouni; E R McVeigh
Journal:  Radiology       Date:  1995-06       Impact factor: 11.105

9.  Irradiation synchronized with respiration gate.

Authors:  K Ohara; T Okumura; M Akisada; T Inada; T Mori; H Yokota; M J Calaguas
Journal:  Int J Radiat Oncol Biol Phys       Date:  1989-10       Impact factor: 7.038

10.  Respiratory gating of cardiac PET data in list-mode acquisition.

Authors:  Lefteris Livieratos; Kim Rajappan; Lars Stegger; Klaus Schafers; Dale L Bailey; Paolo G Camici
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-01-17       Impact factor: 9.236

View more
  4 in total

1.  A further step towards getting cardiac respiratory motion under control.

Authors:  Andreas A Giannopoulos; Ronny R Buechel
Journal:  J Nucl Cardiol       Date:  2017-02-28       Impact factor: 5.952

2.  Respiratory motion reduction with a dual gating approach in myocardial perfusion SPECT: Effect on left ventricular functional parameters.

Authors:  Matti J Kortelainen; Tuomas M Koivumäki; Marko J Vauhkonen; Marja K Hedman; Satu T J Kärkkäinen; Juanita Niño Quintero; Mikko A Hakulinen
Journal:  J Nucl Cardiol       Date:  2017-03-16       Impact factor: 5.952

3.  Clinical evaluation of three respiratory gating schemes for different respiratory patterns on cardiac SPECT.

Authors:  Duo Zhang; Jingzhang Sun; P Hendrik Pretorius; Michael King; Greta S P Mok
Journal:  Med Phys       Date:  2020-07-18       Impact factor: 4.071

4.  Data-driven respiratory signal estimation from temporally finely sampled projection data in conventional cardiac perfusion SPECT imaging.

Authors:  P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2021-12-13       Impact factor: 4.506

  4 in total